BEGA 24901K3 Recessed Ceiling Luminaire Instruction Manual

June 1, 2024
BEGA

**BEGA 24901K3 Recessed Ceiling Luminaire Instruction Manual

**

Instructions for use

Recessed ceiling luminaire
Recessed ceiling luminaire

Application
Recessed ceiling luminaire with attached connecting cable for installation into concrete ceilings or suspended ceilings both indoors and out.
With symmetrical wide beam light distribution

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or white
Clear safety glass
Reflector surface made of pure aluminium Luminaire housing with 2 fixing claws and guide screws
Recessed opening ø 160mm
Required installation depth 120mm
Connecting cable H05RN-F 3G1@ with free line ends
Cable length 0,5m
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V x 0/50-60 Hz
DC 170-276 V
Safety class : I
Protection class IP 65
Dust-tight and protection against water jets
Conformity mark
This product contains light sources of energy efficiency class(es) B

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71320.

Lamp

Module connected wattage : 13.7 W
Luminaire connected wattage : 15.5 W
Rated temperature : ta=25 °C
Service life criteria : 50000 h/L70

24 901K3

Module designation : LED-1628/830
Colour temperature : 3000 K
Colour rendering index :  CRI >80
Module luminous flux : 2820 lm
Luminaire luminous flux : 1980 lm
Luminaire luminous efficiency :
127,7 lm/W

24 901K4

Module designation : LED-1628/840
Colour temperature : 4000 K
Colour rendering index : CRI >80
Module luminous flux : 2890 lm
**Luminaire luminous flux * 2030 lm
Luminaire luminous efficiency* 131 lm/W

  • preliminary data

Lighting technology

Half beam angle 80°

Installation

Luminaire housing must not be installed in heat-insulating material.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using two adjustable wedgeshaped claws.
A recessed opening of ø 160 mm with a minimum depth of 120mm is required.
The lateral distance between the luminaire housing and parts of the building must be at least 50mm.
The claws grip behind the ceiling cladding. The minimum thickness of the ceiling cladding is 1mm.
Ensure that the suspended ceiling and wall surfaces have sufficient load- bearing capability.
If the thickness is less, and if installation is to be carried out in plasterboard ceilings, the back of the ceiling cladding must be reinforced in the region of the claws.

The electrical connection of the free cable end must be carried out with matching protection class and safety class, relieved of strain, with suitable connection terminals in a suitable connection box (not included in the scope of delivery).
Note correct configuration of the mains supply cable. Make mains supply connection at the black (L), blue (N) and green-yellow lead (1).

Insert luminaire housing into the recessed opening. Hand-tighten screws of the claw fastener (torx drive T15) evenly. Do not use an electric screwdriver!
When tightening the screws, the fixing claws must swivel onto the inside of the suspended ceiling. The luminaire is fixed.
When undoing the guide screws, the fixing claws swivel back and the luminaire can be removed.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free
cleansers from dirt and deposits.
Do not use high pressure cleaners.

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Replacing the LED module
The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified
persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the
LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

Spare glass : 14 000 383
LED power supply unit : DEV-0341/350
LED module : 3000 K LED-1628/830
LED module : 4000 K LED-1628/840
Reflector with diffuser disk : 76 002 150
Reflector : 76 002 154
Gasket : 83 002 316

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com 3/3

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals