BEGA 85086 Compact Downlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
85086 Compact Downlight
**Instruction Manua
**
85086 Compact Downlight
Technical amendments reserved
Compact downlight with minimal diffuse light percentage
Instructions for use
Application
Compact floodlights with G½ connecting thread.
The floodlight can be screwed on by the customer with any G½ female thread
according to ISO 228 or with BEGA accessories.
BEGA Ultradark Optics® offer a maximum of illumination and eye comfort due to
a minimised diffuse light percentage and highly efficient glare suppression.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure®
coating technology Colour graphite or silver Matt safety glass Internal
louvres and polymer lens BEGA Ultradark Optics®
Louvres and interior surface of anti-glare ring with maximum light-absorbing
ultra-black nano-coating
Rotation range of floodlight 350°
Swivel range -30°/+125°
Mounting bracket with G½ threaded connection
Thread length: 11 mm
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables BEGA Thermal
Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical
impacts < 2 joule
– Safety mark
****– Conformity mark
Weight: 5.0 kg
This product contains light sources of energy efficiency class(es) F
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Please note:
Contact with the inner surface of the luminaire reflector should be avoided in order to permanently protect the special stray lightminimising properties of the nano-coating.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory. G½ threaded connection torque = 40 Nm. Secure the
screw connection from loosening on site (if provided with locking screw S, see
fig. A).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust
floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 30
mm) and set the desired beam direction.
Torque:
Hexagon socket screw = 7 Nm
Hexagon nut = 35 Nm
Secure bolted connection G1/2 against loosening by tightening the hexagon
socket screw (wrench size 2 mm) (see sketch B, C).
The electrical connection must be carried out with matching protection class
and safety class, strain-relieved, with suitable connection terminals (not
included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable.
Make mains supply connection at the brown (L), blue (N) and green-yellow lead
( ****). The connection of the control cables is achieved by means of the both
leads marked with DALI.
In case these leads are not used the luminaire will be operated at full light
output.
Lamp
Module connected wattage | 55.5 W |
---|---|
Luminaire connected wattage | 60 W |
Rated temperature | t = 25 °Ca |
Ambient temperature | ta max = 45 °C |
85 086 K3
Module designation | LED-1263/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 5985 lm |
Luminaire luminous flux | 4095 lm |
Luminaire luminous efficiency | 68,2 lm / W |
85 086 K4
Module designation | LED-1263/940 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 6490 lm |
Luminaire luminous flux | 4440 lm |
Luminaire luminous efficiency | 74 lm / W |
Lighting technology
Symmetrically focused wide beam light distribution with minimal diffuse light
percentage.
Half beam angle 25°
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by a
qualified person using commercially available tools.
Disconnect the system from the power supply.
Open the floodlight:
Loosen the back locking pin (hexagon socket wrench size 2) in the trim ring.
Remove the trim ring along with the safety glass and reflector by twisting it
anti-clockwise.
Please note:
Contact with the inner surfaces of the louvres and luminaire reflector should
be avoided in order to permanently protect the special stray light-minimising
properties of the nano-coating.
Grasp the louvres from the outside and lift them out. Loosen the three
mounting screws (Torx drive T20) and lift the lens holder (with the loosely
inserted lenses) upward horizontally out of the housing.
Replace LED module.
Please follow the installation instructions for the LED module.
Install in reverse order.
When installing the lens holder, make sure that the LED connecting cable is
not pinched.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that
the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.
Accessories
71 282 | Shield |
---|---|
71 287 | Cylindrical shield |
71 042 | Adapter for installation on a pole |
70 214 | Pole cap for pole top ø 48 mm |
70 248 | Pole cap for pole top ø 60 mm |
70 249 | Pole cap for pole top ø 76 mm |
70 229 | Pole cap for pole top ø 82 mm |
70 245 | Mounting box · rectangular |
70 280 | Tube clamp |
70 379 | Cross beam |
70 889 | Lashing strap |
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass | 25 000 236 |
---|---|
Trim ring silver with glass | 25 000 237 |
LED power supply unit | DEV-0356/1400i |
LED module 3000 K | LED-1263/930 |
LED module 4000 K | LED-1263/940 |
Gasket trim ring | 83 002 145 |
Gasket Gehäuse | 83 002 225 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>