BEGA 50020P Wall and Ceiling Light Instruction Manual

June 1, 2024
BEGA

50 020 P Technical amendments reserved

50020P Wall and Ceiling Light

Ceiling and wall luminaire for indoor use
BEGA 50020P Wall and Ceiling Light - overview Instructions for use

Application

Ceiling and wall luminaire · indoor luminaire made of impact resistant synthetic diffuser and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.
Luminaire with HF-motion sensor.

Product description

Metal housing, finish colour white
Impact resistant synthetic diffuser, white, with bayonet closure
Integrated HF-motion sensor, maximum range 8 m
2 mounting holes ø 6 mm
Distance apart 340 mm
2 cable entries for through-wiring for mains
cable up to ø 10.5 mm max. 3 × 1.5@
Connection terminal 2.5@
Earth conductor connection
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 230 V 50 Hz
BEGA Thermal Switch ® Temporary thermal shutdown to protect temperature- sensitive components
Safety class I
– Conformity mark
Weight: 3.0 kg
This product contains light sources of energy efficiency class(es) D, E

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection againste. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp
Module connected wattage ………………………42.6 W
Luminaire connected wattage ………………………48.8 W
Rated temperature ta ……………………… 25 °C
Ambient temperature ta max ………………………30 °C
50 020 P K27
Colour temperature ……………………… 2700 K
Colour rendering index ……………………… CRI > 90
Module luminous flux ……………………… 6225 lm
Luminaire luminous flux ……………………… 4691 lm
Luminaire luminous efficiency ……………………… 96,1 lm / W
50 020 P K3
Colour temperature ……………………… 3000 K
Colour rendering index ………………………CRI > 90
Module luminous flux ……………………… 6435 lm
Luminaire luminous flux ………………………  4850 lm
Luminaire luminous efficiency ………………………  99,4 lm / W
50 020 P K4
Colour temperature ……………………… 4000 K
Colour rendering index ………………………CRI > 90
Module luminous flux ………………………6695 lm
Luminaire luminous flux ……………………… 5045 lm
Luminaire luminous efficiency………………………103,4 lm / W
Luminaire with trim ring:
Before installing onto the mounting surface the luminaire housing must be inserted into the trim ring (accessory).

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Pass the mains supply cable through the grommet into luminaire housing.
Fix luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
It is imperative to use the enclosed gaskets.
Dismantle the mains supply cable approx. 60 mm.
Make earth and electrical connection to the terminals.
Place the synthetic diffuser to the luminaire housing and observe that the cam pins fit into the notches of the synthetic diffuser.
Screw in synthetic diffuser by turning it clockwise.
Thus, you reach a safe and vibration- resistant holding of the synthetic diffuser.
To release the synthetic diffuser from the luminaire housing, turn it counter- clockwise. BEGA 50020P Wall and Ceiling Light - overview
1The built-in motion sensor operates at a frequency of 5.8 GHz.
By moving within the detection range the motion sensor switches on the LED module inside the luminaire with a defined dwell time – push-button “Dwell time”.
With a wall mounting height of 1.8 m or ceiling mounting height of 2.6 m, the maximum range is 8 meters (see sketch).    BEGA 50020P Wall and Ceiling
Light - overview 2The max. wall mounting height is 2.7 m and the max. ceiling mounting height is 4.0 m, in which the range reduces significantly.
The range can be set individually – push-button “Sensitivity”.
It should be noted that metal parts which are mounted in close proximity to the luminaire can affect the range.
With the three integrated push-buttons
(Brightness, Dwell time and Sensitivity) on the motion sensor, specific settings can be made.
The first keypress activates the setting function.
Press a push-button to switch each function to the next level, the LED indicator on the motion sensor flashes to confirm.
After reaching the highest level, the level setting begins with “Level 1”.

BEGA 50020P Wall and Ceiling Light - overview 3The integrated motion sensor can be set individually with the brightness levels on the ambient brightness – Press the button “Brightness”.
Further individual illumination levels can be used with the button “Brightness” and set with the “learning mode”.
Press button “brightness” (> 3 s) to enable the “learning mode”. There is a slow flashing of the LED indicator.
After about two minutes, the current brightness value is measured for one minute, the LED flashes faster.
After completion, the measured brightness value is saved and is available in stage 6 of “Brightness” as the new brightness value.
To simplify the initial operation, the settings have been made as follows:
Range = 75% (6 m)
Dwell time = 10 s
Light sensor = daylight

Factory Reset
The motion sensor can be reset to factory settings (MICAS) by simultaneously pressing the buttons “Sensitivity” and “Dwell time” for about 5 s.
The factory settings are as follows:
Range = 75% (6 m)
Dwell time = 900 s
Light sensor = daylight
Test mode
The test mode can be used to check the change of settings of the motion sensor.
Press button “Sensitivity” (> 3 s) to enable the “test mode”.
Each further keystroke of this push-button prolongs the test mode.
The active test mode is displayed by a flashing of the LED indicator (2 s interval).
After 3 minutes the test mode is automatically disabled.

Replacement of the LED unit

The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew synthetic diffuser from luminaire housing by turning it counter- clockwise.
Disassemble LED unit.
Assemble LED replacement unit.
Note installation instructions of the LED unit.
Screw in synthetic diffuser by turning it clockwise.
A damaged synthetic diffuser must be replaced.

Accessory · Trim rings

For this luminaire metal trim rings in 3 enamel surfaces are optional available.
Trim rings are accessories and must be ordered separately.

Item Part. No
Colour white 13 007
Colour palladium 13 008
Colour glossy silver 13 009

Spares

Synthetic cover 15 000 634
HF-motion sensor 61 001 077
LED power supply unit DEV-0291/1050
LED unit 2700 K 75 003 525 K27
LED unit 3000 K 75 003 525 K3
LED unit 4000 K 75 003 525 K4

BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com 
www.bega.com

Documents / Resources

| BEGA 50020P Wall and Ceiling Light [pdf] Instruction Manual
50020PK27, 50020PK3, 50020PK4, 50020P Wall and Ceiling Light, 50020P, Wall and Ceiling Light, Ceiling Light, Light
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals