Specifications:

  • Luminaire made of cast aluminium, aluminium, and stainless steel
  • Colour options: graphite or white
  • Polymer lens
  • Distance apart: 39 mm
  • Protection class: IP 65
  • Energy efficiency class: D
  • Weight: 0.25 kg
  • Module connected wattage: 5 W
  • Luminaire connected wattage: 5.9 W
  • Rated voltage: 48 V = DC
  • Colour temperature: 3000 K
  • Colour rendering index (CRI): > 80
  • Module luminous flux: 860 lm
  • Luminaire luminous flux: 627 lm
  • Luminaire luminous efficiency: 106.3 lm/W

Product Usage Instructions

Lighting Technology:
This luminaire contains high-quality electronic components. Avoid direct contact with the light output opening of the LED during installation or relamping. Use a separate power supply unit to operate the luminaire.

Safety:
Installation and operation must adhere to national safety regulations. Only a qualified electrician should carry out  installation and commissioning. The manufacturer is not liable fordamage due to improper use or installation. Any modifications must be done by authorized personnel.

Installation:
The luminaire requires an operating device that meets EN 61347-2-13 standards. The maximum idle voltage of 48 V DC should comply with SELV or SELV equivalent standards.

Connection:

  1. Ensure correct wiring from the external 48 V power supply:
    • Connect the wire from the negative pole to the terminal marked LED -.
    • Connect the wire from the positive pole to the terminal marked LED +.
  2. Center the LED module on the mounting plate and secure it in place.

FAQ:

  • Q: Can this luminaire be used outdoors?
    A: Yes, this luminaire is suitable for both interior and exterior lighting applications.

  • Q: What is the protection class of this luminaire?
    A: This luminaire has a protection class of IP 65.

  • Q: What is the energy efficiency class of this product?
    A: The energy efficiency class of this product is D.

Application

Ceiling mounted spot with small dimensions and high light output for a variety of lighting tasks in interior and exterior lighting applications. For danger- free operation in areas reserved for low voltage systems.

Product description

  • Luminaire made of cast aluminium, aluminium and stainless steel

  • BEGA Unidure® coating technology

  • Colour graphite or white

  • Polymer lens

  • 2 mounting holes ø 4.8 mm

  • Distance apart 39 mm

  • 1 cable entry for connecting cable

  • up to ø 10,5 mm max. 2 × 1,5

  • Connecting terminals 2.5

  • Safety class
    Protection class IP 65

  • Dust-tight and protection against water jets

  •   – Conformity mark

  • Weight: 0.25 kg

  • This product contains light sources of energy efficiency class(es) D

Lamp

  • Module connected wattage 5 W
  • Luminaire connected wattage 5.9 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 60 °C
  • Voltage 48 V = DC

24 793 K3

  • Module designation LED-1443/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 860 lm
  • Luminaire luminous flux 627 lm
  • Luminaire luminous efficiency 106,3 lm / W

Lighting technology
Symmetrical wide beam light distribution Half beam angle 58°

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Please note:
The luminaire can only be operated with an operating device that fulfills the requirements according to EN 61347-2-13. The maximum idle voltage of 48 V DC must conform to SELV or SELV equivalent.

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

A separate power supply unit is required to operate the luminaire (see Accessories).

  • Uninstall the luminaire housing.
  • To do this, insert a small screwdriver into the openings at the side of the luminaire housing.
  • Press the springs inwards and lift out the luminaire housing.
  • Loosen the hexagon socket screws (wrench size 3) slightly and turn the round blank with LED module to the side.
  • Make sure to avoid any direct contact with the PCB.
  • To do so, only touch the round blank at its outer edge.
  • Pass the connecting cable through the cable entry in the mounting plate.
  • Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
  • Be sure to use the gasket rings supplied.
  • Push silicone sleeves over the lines and make electrical connection.
  • Please ensure correct wire assignment for the connecting cable of the external 48 V power supply unit.
  • The wire from the minus pole must be connected to the free terminal of the luminaire marked with LED -, the wire from the plus pole to the terminal marked with LED +.
  • Guide the round blank with LED module onto the mounting plate in a central position and fasten in place with the two hexagon socket screws.
  • Guide the luminaire housing onto the mounting plate so that the two openings in the housing are aligned with the two spring elements of the mounting plate.
  • Press on the luminaire housing and make sure that the two springs engage in the openings.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Close the luminaire.

DIMENSION

BEGA-24-793-Ceiling-Mounted-Spot-1

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.
  • For lacquered surfaces we recommend the use of BEGA Lacquer Care Set 71 179.

Accessories
External power supply units 48 V DC 220-240 V ∙ 0/50-60 Hz

  • 13 619 On/off power supply unit
  • 13 620 Power supply unit DALI

For the accessories a separate instructions for use can be provided upon request.

Spares

  • LED module 3000 K LED-1443/830
  • Gasket 83 002 220

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden