BEGA 22109 Wall Luminaire with Unshielded Light Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
BEGA 22109 Wall Luminaire with Unshielded Light
Dimension
Instructions for use
Application
Wall luminaire with unshielded light for surface mounted installation.
Lamp
Module connected wattage 1.9 W
Luminaire connected wattage 2.3 W
Rated temperature ta=25 °C
Ambient temperature ta max=60 °C
When installed in heat-insulating material ta max=50 °C
Voltage 24 V = DC
22 109K3
Module designation LED-0312/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 285 lm
Luminaire luminous flux 31 lm
Luminaire luminous efficiency 13,5 lm/W
22 109K4
Module designation LED-0312/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 295 lm
Luminaire luminous flux 32 lm
Luminaire luminous efficiency 13,9 lm/W
Product description
LED recessed luminaire without power supply uni
Luminaire made of cast aluminium,
aluminium and stainless steel
BEGA Unidure® coating technology
Safety glass, white
Silicone gasket
Recessed opening ø 71mm
Required installation depth 90mm
Fixing is achieved by using two adjustable
wedge-shaped claws
1 cable entry
for connecting cable max. ø 10,5mm
Connecting terminals 2.5❑
Safety class III
Protection class IP 65
Dust-tight and protection against water jets
– Safety mark
Impact strength IK08
Protection against mechanical
impacts < 5 joule
– Conformity mark
Weight: 0.25 kg
This product contains light sources of energy efficiency class(es) D
Please note:
The luminaire must not have permanently contact with aggressive media.
Aggressive media can be washed out of building materials and destroy the
housing of the luminaire. In case of an unknown composition of the building
materials a material analysis is to be carried out before installation of the
luminaire. Aggressive media that is outgoing from the surface might also
affect the luminaire. Thus an overuse of cleaning agents in the surroundings
of the luminaire must be avoided.
Please note:
The luminaire can only be operated with an operating device that fulfills
the requirements according to EN 61347-2-13.
The maximum idle voltage of 60 V DC must conform to SELV or SELV equivalent.
Installation
The electrical connection must only be made to safety transformers according
to EN 61558 – see accessories.
The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using two adjustable
wedge shaped claws.
Installation into solid walls:
For this purpose installation housing 10 415 is available. If the installation
housing cannot be used a recessed opening ø 71mm is necessary to accept the
luminaire housing.
Recessed depth min. 90mm.
Installation into wall panels:
A recessed opening of ø 71mm is necessary to accept the luminaire housing.
Recessed depth min. 90mm. The lateral distance between recessed luminaire and
other building parts must be at least 50mm. The claws catch the wall panel
from the back side.
Minimum thickness of the wall panel is 4mm.
If the wall panel has a thickness of less than 4mm, the panel thickness must
be increased from the back side.
Undo screws. Remove front plate with glass and gasket.
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Disassemble tray for electrical equipment.
Do not remove the desiccant pouch from the luminaire housing.
It is needed to remove residual moisture.
Lead the secondary connecting cable supplied by others from the power supply
unit through the compression nipple into the luminaire housing.
Make electrical connection:
Connect black conductor with negative pole and red conductor with positive
pole of the power supply unit.
A 24 V safety direct voltage source with a smoothed residual ripple of max. 10
% is required for the electrical connection of the luminaire – see
accessories.
If other safety direct voltage sources are used, an upstream fuse (max. 6 A)
must be provided by the customer.
Assemble tray for electrical equipment.
Push luminaire housing into the recessed opening.
Hand-tighten screws of claw fastener evenly.
Do not use an electric screwdriver!
Place glass with gasket with stepped side upturned onto the housing.
Make sure gasket is in correct position.
Assemble faceplate.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Accessories
Power supply unit for LED luminaires 24 V DC
Safety transformer according to EN 61558/VDE 0570 part 2-6
70 564 Power supply unit for 5-15 W
70 465 Power supply unit for 10-25 W
70 565 Power supply unit for 20-35 W
70 566 Power supply unit for 30-50 W
70 567 Power supply unit for 40-75 W
70 169 Power supply unit for 70-150 W 230 V y 50-60 Hz
71 134 Power supply unit for 0-70 W
AC range: AC: 198-264 V y 50-60 Hz
DC range: DC: 176-275 V
The power supply units are also suitable for the operation of several LED luminaires. In this case, the maximum wattage of the power supply unit must not be exceeded.
10 415 Installation housing
For the accessories a separate instructions for use can be provided upon request.
Spares
Spare glass 14 000 505
LED module 3000 K LED-0312/930
LED module 4000 K LED-0312/940
Gasket 83 000 887 .1
Customers Support
BEGA Gantenbrink-Leuchten KG
Postfach 3160
58689 Menden
info@bega.com
www.bega.com