BEGA 50654.2K3 Wall and Ceiling Light Instruction Manual

June 1, 2024
BEGA

BEGA 50654.2K3 Wall and Ceiling Light

BEGA-50654-2K3-Wall-and-Ceiling-Light-PRO

Product Information

Specifications:

  • Lamp Module connected wattage: 25.3 W
  • Luminaire connected wattage: 29 W
  • Rated temperature: 25-40°C
  • Ambient temperature: max 25-40°C
  • Colour temperature: 3000 K (LED-0570/930), 4000 K (LED-0570/940)
  • Colour rendering index (CRI): > 90
  • Module luminous flux: 3615 lm (3000 K), 3760 lm (4000 K)
  • Luminaire luminous flux: 2263 lm (3000 K), 2354 lm (4000 K)
  • Luminaire luminous efficiency: 78 lm/W (3000 K), 81.2 lm/W (4000 K)

Product Usage Instructions

Overvoltage Protection:
The luminaire has built-in protection against overvoltage according to DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.

Safety:
Installation and operation of the luminaire must comply with national safety regulations. Only a qualified electrician should carry out the installation and commissioning. The manufacturer is not liable for damage due to improper use or installation. Any modifications to the luminaire must be done by authorized personnel.

Replacement Parts:
Available spare parts include spare glass, LED power supply unit, LED module 3000 K, and LED module 4000 K. Refer to the part numbers for ordering replacements.

FAQ

  • Q: Can I replace the LED modules myself?
    A: No, LED module replacements should be carried out by a qualified technician to ensure proper installation and safety.

  • Q: What should I do if the luminaire is damaged during installation?
    A: Contact a qualified electrician or the manufacturer for guidance on handling damaged luminaires.

Application

Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass, satin matt and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.

Product Description

  • Metal housing, finish colour white aluminium Hand-blown opal glass, satin matt, with sliding-bolt closure
  • 2 mounting holes ø 5.5 mm
  • Distance apart 240 mm
  • 2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@ Connecting terminal 2.5@
  • with plug connection
  • Earth conductor connection
  • Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit
  • 220-240 V 0/50-60 Hz
  • DC 170-280 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies
  • ≥ 1 mm and splash water
  • Impact strength IK07
  • Protection against mechanical
  • impacts < 2 joule
  •  – Safety mark
  •   – Conformity mark
  • Weight: 4.4 kg
  • This product contains light sources of energy efficiency class(es) D, E

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

  • Module connected wattage 25.3 W
  • Luminaire connected wattage 29 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

50 654.2 K3

  • Module designation LED-0570/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 3615 lm
  • Luminaire luminous flux 2263 lm
  • Luminaire luminous efficiency 78 lm / W

50 654.2 K4

  • Module designation LED-0570/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 3760 lm
  • Luminaire luminous flux 2354 lm
  • Luminaire luminous efficiency 81,2 lm / W

Installation

  • LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Disassemble LED module.
  • Loosen LED connection and earth connection (plug connection).
  • Dismantle the mains supply cable max. 80 mm.
  • Lead mains supply cable through the cable entry into the luminaire housing.
  • Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
  • It is imperative to use the enclosed gaskets.
  • Make earth and electrical connection to the terminal.
  • Make earth connection between LED module and luminaire housing (plug connection).
  • Push LED-plugs into couplers as far as it will go.
  • Assemble LED module.
  • Tighten the screws evenly (max. 0,8 Nm).
  • Please observe that the LED module is not damaged mechanically.
  • Place glass to the luminaire housing with sliding bolt glass closure and observe that the holding springbolts fit into the notches of the glass.

IMPORTANT! The glass must be turned clockwise past the first instance of palpable spring resistance.

By continuing to turn the glass, the glass retaining spring enters the “resting zone” of the glass. The end position of the glass is reached via a palpably firm stop.
Thus, you reach a safe and vibration-resistant holding of the glass.
To release the glass from the luminaire housing, turn it counter-clockwise.

DIMENSION

BEGA-50654-2K3-Wall-and-Ceiling-Light-1

Replacement of the LED module · Maintenance

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.
  • Unscrew glass from luminaire housing by turning it counter-clockwise.
  • Clean glass and luminaire regularly with solvent-free cleansers from dirt.
  • Please follow the installation instructions for the LED module.
  • Screw in glass by turning it clockwise as far as it will go.
  • A broken glass must be replaced.

Spares

  • Spare glass 11 002 771 .0R G
  • LED power supply unit DEV-0291/850
  • LED module 3000 K LED-0570/930
  • LED module 4000 K LED-0570/940

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals