BEGA 33062 Recessed Wall Luminaire Instruction Manual

June 1, 2024
BEGA

BEGA 33062 Recessed Wall Luminaire

BEGA-33062-Recessed-Wall-Luminaire-Product

Product Information

Specifications:

  • Luminaire made of aluminium alloy, aluminium, and stainless steel
  • Colour options: graphite or silver
  • Safety glass with optical structure
  • Silicone gasket
  • Reflector made of pure anodised aluminium
  • Fixing with two adjustable wedge-shaped claws
  • Required recessed opening: 315 x 110 mm
  • Recessed depth: 90 mm
  • LED power supply unit: 220-240 V x 0/50-60 Hz DC 176-276 V
  • DALI-controllable with one DALI address
  • Safety class I
  • Protection class IP65 for dust-tight and protection against water jets
  • Impact strength IK08

Product Usage Instructions

Installation:

  1. Ensure to follow national safety regulations during installation.
  2. Installation and commissioning should only be done by a qualified electrician.
  3. Use bounce-free switching contacts for optimal protection of electronic components.

Maintenance:
Use chemical cleaning agents cautiously around the luminaire if coated with BEGA Tricoatb to avoid damage to the coating.

FAQ:

  • Q: Can this luminaire be used for surface mounting?
    A: Yes, this luminaire can be used for flush or surface mounting installations.

  • Q: What is the recommended power supply for this luminaire?
    A: The recommended LED power supply unit is rated at 220-240 V x 0/50-60 Hz DC 176-276 V.

Application

  • Recessed wall luminaire with asymmetrical flat beam light distribution, for flush or surface mounting installation.
  • For the wide beam and uniform illumination of surfaces and paths.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Tricoat® coating technology
  • Colour graphite or silver
  • Safety glass with optical structure
  • Silicone gasket
  • Reflector made of pure anodised aluminium
  • Fixing is achieved by using two adjustable wedge-shaped claws
  • Required recessed opening 315 x 110 mm
  • Recessed depth 90 mm 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@
  • Connecting terminal and earth conductor terminal 2.5@
  • BEGA Ultimate Driver®
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-276 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK08
  • Protection against mechanical impacts < 5 joule
  • – Safety mark
  • – Conformity mark
  • Weight: 2.0 kg
  • This product contains light sources of energy efficiency class(es) C

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.
  • The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Please note:

  • This luminaire is coated with BEGA Tricoatb.
  • BEGA Tricoatb is a registered trademark for a technology that we use to achieve optimal corrosion resistance.
  • Even the best possible surface protection and the highest corrosion resistance can be rendered almost ineffective in some cases by aggressive media caused by the leaching of building materials.
  • Where such media are suspected, a material analysis must be carried out before installation.
  • Always avoid excessive use of chemical cleaning agents in the vicinity of the luminaire.

Installation

  • The recessed opening will be covered by the frame of the luminaire housing.

  • Fixing of the luminaire is achieved by using two adjustable wedge-shaped claws.

  • Installation in solid, plastered walls:
    The installation housing 10 436 is available for this purpose. If this is not used, an exact recessed opening of 315 x 110 mm with a minimum depth of 90 mm is required.

  • Installation in exposed brickwork:
    The construction of an on-site recessed opening with the exact installation dimensions of 315 x 110 mm with a minimum depth of 90 mm is required. An installation housing cannot be used.

  • Installation in drywalling:
    A recessed opening of 315 x 110 mm with a minimum depth of 90 mm is required. The claws grip behind drywall.

  • Installation into insulated façades:
    For installation in EWIS external wall insulation systems please use installation housing 13 522 in combination with a plaster frame 10 036 or 13

Open luminaire:

  • Undo the screws and remove the housing cover.
  • Disconnect the plug-connection of the LED connecting cable.
  • Disconnect the earth conductor connection from the plug connection.
  • Lead the main supply cable through the cable entry into the luminaire housing.
  • Make the earth conductor connection and the electrical connection.
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • To guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
  • Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
  • Connect the LED connection cable using a plug connector.
  • Put on earth conductor connection of the housing cover. Assemble the housing cover.
  • Make sure that the gasket is positioned correctly.
  • Tighten the screws evenly.
  • Insert luminaire housing into the recessed opening. Hand-tighten the screws of the claw fastener evenly. Do not use an electric screwdriver!

Dimension

BEGA-33062-Recessed-Wall-Luminaire-Fig- \(1\)

Lamp

  • Module connected wattage 12 W
  • Luminaire connected wattage 15 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C
  • When installed in heat-insulating material ta max = 35 °C

33 062 K3

  • Module designation LED-0575/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 2095 lm
  • Luminaire luminous flux 1331 lm
  • Luminaire luminous efficiency 88,7 lm/W

33 062 K4

  • Module designation LED-0575/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 2125 lm
  • Luminaire luminous flux 1350 lm
  • Luminaire luminous efficiency 90 lm/W

Cleaning And Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • The defective glass must be replaced.
  • Close the luminaire.

Accessories

  • 10 436 Installation housing
  • 13 522 Installation housing for installation in insulated façades (EWIS)
  • 10 036 Plaster frame
  • 13 506 Plaster frame flush

Separate instructions for use can be provided upon request.

Spares Parts

  • LED power supply unit DEV-0312/700
  • LED module 3000 K LED-0575/830
  • LED module 4000 K LED-0575/840
  • Reflector 76 001 442
  • Gasket 83 001 561

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals