BEGA 24210 Recessed Ceiling and Wall Luminaire
Specifications
- Model: 24 210
- Application: Recessed ceiling and wall luminaire with asymmetrical light distribution for flush or surface mounted installation
- Features: Glare-free lighting of ceiling, wall, and ground surfaces
- Connected Wattage:
- Lamp Module: 2.9 W
- Luminaire: 4 W
- Colour Temperature: 3000 K
- Colour Rendering Index (CRI): >80
- Luminous Flux:
- Module: 560 lm
- Luminaire: 310 lm
- Luminous Efficiency: 77.5 lm/W
Product Usage Instructions
Safety Instructions
The installation and operation of this luminaire should be done in
accordance with national safety regulations. Only a qualified electrician
should carry out the installation and commissioning.
Assembly and Installation
- Open the luminaire by undoing screws and removing the housing cover.
- Disconnect the plug connection of the LED connecting cable and the earth conductor connection.
- Lead the mains supply cable through the cable entry into the luminaire housing.
- Make the earth conductor connection and the electrical connection.
- Place the enclosed desiccant pouch in the luminaire to ensure maximum service life of electrical components.
- Connect the LED connection cable using a plug connector and put on the earth conductor connection of the housing cover.
- Assemble the housing cover ensuring correct positioning of the gasket and tighten the screws evenly.
- Insert the luminaire housing into the recessed opening and hand-tighten screws of the claw fastener evenly. Do not use an electric screwdriver.
FAQ
-
Q: What is the ideal protection for electronic components in the luminaire?
A: Using bounce-free switching contacts like an electronic relay provides ideal protection for all electronic components. Additionally, overvoltage protection components are recommended for further protection against transients. -
Q: What is the purpose of the desiccant pouch in the luminaire?
A: The desiccant pouch is placed in the luminaire to ensure the maximum service life of electrical components by absorbing moisture.
Recessed wall and ceiling luminaire
Instructions for use
Application
- Recessed ceiling and wall luminaire with asymmetrical light distribution for flush or surface mounted installation.
- For glare-free lighting of ceiling, wall and ground surfaces.
Product description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Tricoat® coating technology
- Clear safety glass
- Silicone gasket
- Required recessed opening 139 x 139 mm Recessed depth 110 mm
- Fixing is achieved by using two adjustable wedge-shaped claws 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm
- Connecting terminal and earth conductor terminal 2.5@
- BEGA Ultimate Driver®
- LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-264 V
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect temperature-sensitive components
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK05
- Protection against mechanical
- impacts < 0.7 joule
- – Safety mark
- – Conformity mark
- Weight: 0.95 kg
- This product contains light sources of energy efficiency class(es) B, C
Safety
- The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
- The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Please note:
- This luminaire is coated with BEGA Tricoatb. BEGA Tricoatb is a registered trademark for a technology that we use to achieve optimal corrosion resistance.
- Even the best possible surface protection and the highest corrosion resistance can be rendered almost ineffective in some cases by aggressive media caused by leaching of building materials.
- Where such media are suspected, a material analysis must be carried out before installation. Always avoid excessive use of chemical cleaning agents in the vicinity of the luminaire.
Installation
-
The recessed opening will be covered by the frame of the luminaire housing.
-
Fixing of the luminaire is achieved by using two adjustable wedge-shaped claws.
-
Installation in concrete ceilings and in solid, plastered walls:
The installation housing 10 463 is available for this purpose. If this is not used, an exact recessed opening of 139 x 139 mm with a minimum depth of 110 mm is required. -
Installation in exposed brickwork:
The construction of an on-site recessed opening with the exact installation dimensions of 139 x 139 mm with a minimum depth of 110 mm is required. An installation housing cannot be used. -
Installation into inserted ceilings and wall panels:
- A recessed opening of 139 x 139 mm with a minimum depth of 110 mm is required.
- The claws grip behind drywall.
-
Installation into insulated façades:
For installation in EWIS external wall insulation systems please use installation housing 13 540 in combination with a plaster frame 10 063 or 10
Open luminaire:
- Undo screws and remove housing cover. Disconnect plug-connection of the LED connecting cable.
- Disconnect the earth conductor connection from the plug connection.
- Lead the mains supply cable through the cable entry into the luminaire housing.
- Make the earth conductor connection and the electrical connection.
- In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
- Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
- Connect the LED connection cable by means of a plug connector.
- Put on earth conductor connection of the housing cover. Assemble housing cover. Make sure that gasket is positioned correctly. Tighten the screws evenly.
- Insert luminaire housing into the recessed opening. Hand-tighten screws of the claw fastener evenly. Do not use an electric screwdriver!
Lamp
- Module connected wattage 2.9 W
- Luminaire connected wattage 4 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 50 °C
- When installed in heat-insulating
- material ta max = 45 °C
24 210 K3
- Module designation LED-0749/830
- Colour temperature 3000 K
- Colour rendering index CRI > 80
- Module luminous flux 560 lm
- Luminaire luminous flux 310 lm
- Luminaire luminous efficiency 77,5 lm / W
24 210 K4
- Module designation LED-0749/840
- Colour temperature 4000 K
- Colour rendering index CRI > 80
- Module luminous flux 580 lm
- Luminaire luminous flux 321 lm
- Luminaire luminous efficiency 80,2 lm / W
Cleaning · Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high pressure cleaners.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- Defective glass must be replaced.
- Close the luminaire.
Accessories
- 10 463 Installation housing
- 13 540 Installation housing for installation in insulated façades (EWIS)
- 10 063 Plaster frame
- 10 072 Plaster frame flush
See the separate instructions for use.
Spares
- LED power supply unit DEV-0303/350
- LED module 3000 K LED-0749/830
- LED module 4000 K LED-0749/840
- Reflector 76 001 616
- Gasket 83 001 769