BEGA 67683.3 Wall Luminaire Instruction Manual

June 1, 2024
BEGA

67 683.3
Wall luminaire for indoor use
BEGA 67683.3 Wall Luminaire - DimensionInstructions for use

Application

Wall luminaire · indoor luminaire made of handblown opal glass, satin matt and metal housing.
For all lighting tasks in interior applications.
Luminaire with a high protection class.

Product description

Die-cast aluminium and aluminium housing, finish Chrome
Hand-blown opal glass, satin matt
Silicone gasket
2 mounting holes ø 5.5 mm
Distance apart 440 x 56 mm
2 cable entries for through-wiring of mains
supply cable ø 7-10.5 mm, max. 5 G 1.5@
Connection terminal 2.5@
Earth conductor connection
2-pole connecting terminal for digital control
LED power supply unit
220-240 V x 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect
temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 44
Protected against granular foreign bodies
≥ 1 mm and splash water
Impact strength IK04
Protection against mechanical
impacts < 0.5 joule
– Safety mark
  – Conformity mark
Weight: 2.0 kg
This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 12.4 W
Luminaire connected wattage 15.3 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 45 °C

67 683.3 K27

Module designation 4x LED-0546/927
Colour temperature 2700 K
Colour rendering index CRI > 90
Module luminous flux 1820 lm
Luminaire luminous flux 1282 lm
Luminaire luminous efficiency 83,8 lm / W

67 683.3 K3

Module designation 4x LED-0546/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 1880 lm
Luminaire luminous flux 1325 lm
Luminaire luminous efficiency 86,6 lm / W

67 683.3 K4

Module designation 4x LED-0546/940
Colour temperature 4000 K
Colour rendering index CRI > 90
Module luminous flux 2020 lm
Luminaire luminous flux 1427 lm
Luminaire luminous efficiency 93,3 lm / W

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Loosen screw of the lateral cover and take off the glass from the luminaire housing.
Lead the mains supply cable through the cable entry into the luminaire housing.
Secure the luminaire housing to the installation surface with the fixing materials provided or other suitable materials.
Make sure to use the gaskets supplied.
Establish earth conductor connection and make the electrical connection to the terminals.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
Position glass into the base plate and fix it with the screw and the cover.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

Spare glass 11 002 799 .0R G
LED power supply unit DEV-0388/370i
LED module 2700 K LED-0546/927
LED module 3000 K LED-0546/930
LED module 4000 K LED-0546/940
Gasket glass 81 000 277 .2
Gasket 83 001 249

BEGA Gantenbrink-Leuchten KG
Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals