BEGA 50 508 Ceiling and Wall Luminaire Instructions

June 1, 2024
BEGA

13.22 · Technical amendments reserved
50 508 Ceiling and wall luminaire for indoor use

50 508 Ceiling and Wall Luminaire

BEGA 50 508 Ceiling and Wall Luminaire - Instructions for
use

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.

Product description
Metal housing, finish colour white
Hand-blown opal glass, satin matt, with bayonet closure
2 mounting holes ø 5.5 mm
Distance apart 230 mm
2 cable entries for through-wiring for mains cable up to ø 11 mm max. 5 x 1.5◻
Connection terminal 2.5◻
Earth conductor connection
2-pole connecting terminal for digital control
LED power supply unit
220-240 0/50-60 Hz
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Safety mark
– Conformity mark
Weight: 2.9 kg
This product contains light sources of energy efficiency class(es) D, E

Safety
The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 26.4 W
 Luminaire connected wattage 29.4 W
Rated temperature ta= 25 °C
Ambient temperature ta max = 50 °C

50 508 K27

Colour temperature 2700 K
Colour rendering index CRI > 90
Module luminous flux 3845 lm
Luminaire luminous flux 2926 lm
Luminaire luminous efficiency 99,5 lm / W

50 508 K3

Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 3970 lm
Luminaire luminous flux 3021 lm
Luminaire luminous efficiency 102,8 lm / W

50 508 K4

Colour temperature 4000 K
Colour rendering index CRI > 90
Module luminous flux 4135 lm
Luminaire luminous flux 3147 lm
Luminaire luminous efficiency 107 lm / W

Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Lead mains supply cable through the cable entry into the luminaire housing.
Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
It is imperative to use the enclosed gaskets.
Make earth and electrical connection to the terminal.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
Place glass to the luminaire housing and observe that the cam pins fit into the notches of the glass.
Screw in glass by turning it clockwise. Thus, you reach a safe and vibration- resistant holding of the glass.
To release the glass from the luminaire housing turn it counter-clockwise.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Replace the LED unit.
Screw in glass by turning it clockwise.
Defective glass must be replaced.

Spares

Spare glass 11 003 569 .ORG
LED unit 2700 K 75 005 349 K27
LED unit 3000 K 75 005 349 K3
LED unit 4000 K 75 005 349 K4

BEGA Gantenbrink-Leuchten KG
· Postfach 31 60 · 58689 Menden
· info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals