BEGA 77 479 Surface Floodlight Instruction Manual

June 1, 2024
BEGA

BEGA 77 479 Surface Floodlight

Instructions For Use

Application

Floodlight with mounting bush G½. for broad spread light distribution.
The floodlight can be bolted together with any female thread G½ according to ISO 228.

Product Description

Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver
Safety glass with optical structure
Silicone gasket
Reflector made of pure anodised aluminium
Rotation range of floodlight 350°
Swivel range -35°/+90°
Mounting bracket with G½ threaded connection
Thread length: 11mm
Connecting cable X05BQ-F 5G1mm²
Cable length 1m
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V 0/50-60 Hz
During DC operation the LED power is reduced to 15%
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets Impact strength IK07
Protection against mechanical impacts < 2 joule
– Safety mark
– Conformity mark
Wind catching area: 0.022 m²
Weight: 1.3 kg
This product contains light sources of energy efficiency class(es) D

Dimension

Dimension

Lighting technology
Half beam angle 76/89°

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage Protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71320.

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.

Screw floodlight mounting bush G½ firmly into the female G½ thread provided on site or into BEGA accessory.
Torque of the mounting bush G½ = 20Nm.
Secure bolted connection against loosening.
Check earth conductor connection between mounting bush G½ and female thread G½ provided on site.
The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable.
Make mains supply connection at the brown (L), blue (N) and green-yellow lead ( ).
The connection of the control cables is achieved by means of the both leads marked with DALI.
In case these leads are not used the luminaire will be operated at full light output.
Adjust the floodlight.
Undo the joint screw and adjust the floodlight.
Tighten the joint screw.
Torque = 7Nm.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Lamp

Module connected wattage| 17.6 W
Luminaire connected wattage| 20.5 W
Rated temperature| ta=25 °C
Ambient temperature| ta max=45 °C
77 479K4
Module designation| LED-0313/940
Colour temperature| 4000 K
Colour rendering index| CRI >90
Module luminous flux| 2940 lm
Luminaire luminous flux| 2295 lm
Luminaire luminous efficiency| 112 lm/W
77 479K3
Module designation| LED-0313/930
Colour temperature| 3000 K
Colour rendering index| CRI >90
Module luminous flux| 2780 lm
Luminaire luminous flux| 2170 lm
Luminaire luminous efficiency| 105,9 lm/W

Please note
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Replacing The LED Module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Accessories

70 214 Pole cap for pole ø 48 mm
70 248 Pole cap for pole ø 60 mm
70 245 Mounting box
70 252 General fastener
70 280 Tube clamp G½
70 283 Screw clamp
70 379 Cross beam G½
70 889 Tension belt
71 042 Adapter for installation on a pole
70 500 Shield

For the accessories a separate instructions for use can be provided upon request.

Spares

Spare glass 14 000 966
LED power supply unit DEV-0494/700i
LED module 3000 K LED-0313/930
LED module 4000 K LED-0313/940
Reflector 76 001 194
Gasket glass 83 001 372
Gasket housing 83 001 386

CUSTOMER SUPPORT

BEGA Gantenbrink- Leucite KG ·
Postrace 3160 · 58689 Menden
info@bega.com 
www.bega.com