BEGA 85009K3 Compact Flood Light Instruction Manual

June 1, 2024
BEGA

BEGA 85009K3 Compact Flood Light

Instruction Manual

Instructions for use

Instructions for use

Application

Floodlight with earthspike, connecting cable and safety plug for portable installation.

Product description

Floodlight made of aluminium alloy, aluminium and stainless steel

  • BEGA Unidure® coating technology
  • Earth spike made of glass fibre reinforced synthetic material
  • Clear safety glass
  • Reflector surface made of pure aluminium Swivel range -45°/+70°
  • No tools are needed to adjust the operating position
  • Ready for connection with 5 m connecting cable H05RN-F 3 G 1@ and mains plug.
  • LED power supply unit 220-240 V y 50/60 Hz
  • Safety class I
  • Protection class safety plug IP X4
  • Protected against splash water
  • Protection class luminaire IP 65
  • Dusttight and protected against water jets Impact strength IK06
  • Protection against mechanical
    impacts < 1 joule
    – Safety mark
    CE – Conformity mark
    Weight: 1.2 kg

This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.

Lamp

Module connected wattage Luminaire connected wattage Rated temperature
Ambient temperature
85 009 K3
Module designation
Colour temperature
Colour rendering index Module luminous flux Luminaire luminous flux  Luminaire luminous efficiency

Lighting technology

Wide beam light distribution Half beam angle 50°

Installation

The electrical connection between safety plug and safety socket outlet must correspond to protection class IP X4.
Press the luminaire with earth spike vertically into the soil until stability is achieved. If necessary, compact soil around the earth spike.

Adjust the floodlight.

Undo the joint screw and adjust the floodlight. Tighten the joint screw.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Replacing the LED module

The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
Disconnect the system from the power supply. Undo hexagon socket head cap screws (torx drive T8) and disassemble end ring with glass, gasket and reflector.
Replace LED module. Please follow the installation instructions for the LED module. Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Screw the trim ring along with glass, gasket and reflector tightly on the luminaire housing.

Accessories

For the electrical connection, we recommend the BEGA connecting pillars with safety sockets.

You can find them on our website at
www.bega.com.

Product Specifications:

  • Module designation: LED-1285/930
  • Colour temperature: 3000 K
  • Colour rendering index (CRI): > 90
  • Module luminous flux: 890 lm
  • Luminaire luminous flux: 631 lm
  • Luminaire luminous efficiency: 85.3 lm/W
  • Lamp Module connected wattage: 6.1 W
  • Luminaire connected wattage: 7.4 W
  • Rated temperature: max 25°C
  • Ambient temperature: 30°C

Product Usage Instructions:

Installation:

1. Ensure the electrical connection between safety plug and safety socket outlet corresponds to protection class IP X4.

2. Press the luminaire with earth spike vertically into the soil until stability is achieved. Compact soil around the earth spike if necessary.

3. Adjust the floodlight by undoing the joint screw, adjusting the floodlight, and then tightening the joint screw.

Maintenance:

1. The connecting cable must be checked for external damage regularly and replaced only by a qualified electrician.

2. Do not remove the desiccant bag from the luminaire housing as it is needed to remove residual moisture.


Frequently Asked Questions (FAQ):

Q: Can I install the luminaire myself?

A: No, installation and commissioning must be carried out by a qualified electrician.

Q: Where can I find overvoltage protection components?

A: Additional protection components, including overvoltage protection, can be found on our website at www.bega.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals