BEGA 33636K3 Ceiling and Wall Luminaire Instruction Manual

June 1, 2024
BEGA

BEGA 33636K3 Ceiling and Wall Luminaire

BEGA-33636K3-Ceiling-and-Wall-Luminaire-PRODUCT

Specifications :

  • Material: Aluminium and hand-blown satin matt three-ply opal glass

  • Power Supply: LED driver 220-240 V x 0/50-60 Hz DC 176-276 V

  • Control: DALI controllable with 1 DALI address

  • Protection Class: I

  • Protection Rating: IP64 (Dust-tight and protection against
    splashing water)

  • Impact Resistance: IK03

  • Weight: 2.0 kg

Installation

  1. Installation and commissioning must be done by a qualified electrician following national safety regulations.
  2. Ensure the power supply is turned off before installation.
  3. Mount the luminaire on the ceiling or wall securely using appropriate hardware.
  4. Connect the luminaire to the power supply following the provided wiring instructions.

Operation

  • The luminaire is suitable for both interior and exterior lighting applications.
  • Ensure the ambient temperature is within the specified range for optimal performance.
  • Use appropriate control systems to adjust the lighting as needed.

Ceiling and wall luminaire

BEGA-33636K3-Ceiling-and-Wall-Luminaire-

Instructions for use

Application

Wall-mounted surface floodlight with asymmetrical light distribution for lighting wall-, ceiling- and ground surfaces.
The luminaire can be installed in any burning position.

Product description

  • Luminaire made of aluminum alloy, aluminum and stainless steel
  • BEGA Unidure® coating technology
  • Color graphite or silver

Safety glass

  • The reflector surface made of pure aluminium
  • Swivel range -30°/+120°
  • Mounting plate with 2 fixing holes ø 5.5 mm · 70 mm spacing
  • 2 cable entries for through-wiring of mains
  • supply cable ø 7-10.5 mm, max. 5 G 1.5@
  • Connecting terminal 2.5@
  • with plug connection
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without
  • switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK08
  • Protection against mechanical
  • impacts < 5 joule
  • – Safety mark
  • – Conformity mark
  • Wind catching area: 0.072 m²
  • Weight: 3.2 kg
  • This product contains light sources of energy efficiency class(es)

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

  • Module connected wattage 19.4 W
  • Luminaire connected wattage 22 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

84 098 K4

  • Module designation LED-0872/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 3310 lm
  • Luminaire luminous flux 2661 lm
  • Luminaire luminous efficiency 121 lm / W

84 098 K3

  • Module designation LED-0872/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 3130 lm
  • Luminaire luminous flux 2516 lm
  • Luminaire luminous efficiency 114,4 lm / W

Installation

  • Open mounting box.
  • Lead mains supply cable through the cable entry into the mounting box.
  • Fix the mounting box with enclosed or any other suitable fixing material onto the mounting surface.
  • Note position of application of the mounting plate “arrow down”.
  • Make earth conductor connection and electrical connection to the connecting terminal (plug connection).
  • Make earth conductor connection between luminaire and mounting plate.
  • Place floodlight onto mounting plate and fix it. Undo joint screw and adjust the slope angle of the surface floodlight.
  • Tighten joint screw firmly.
  • Torque = 14 Nm

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Accessory

10 409 Corner block
Corner block for installation of wall lights on a house corner.

Spares

  • LED power supply unit DEV-0485/700i
  • LED module 3000 K LED-0872/930
  • LED module 4000 K LED-0872/940
  • Reflector 76 001 648
  • Gasket housing 83 001 653
  • Gasket mounting box 83 001 903

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals