BEGA 84446 Performance Floodlight RGBW Instruction Manual

June 1, 2024
BEGA

BEGA 84446 Performance Floodlight RGBW

Specifications:

  • Module designation: LED-1104/RGBW
  • Color temperature of the white LED: 4000 K
  • Luminaire luminous flux: 2239 lm
  • Luminaire luminous efficiency: 49.8 lm/W
  • Lamp Module connected wattage: 40.5 W
  • Luminaire connected wattage: 45 W
  • Rated temperature: 25 – 35°C
  • Ambient temperature: 25 – 35°C

Product Usage Instructions

Safety Precautions:

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning should only be carried out by a qualified electrician. The manufacturer does not accept liability for damage caused by improper use or installation.

Overvoltage Protection:

The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547.
For additional protection against transients, separate overvoltage protection components are recommended.

Installation:

  1. Ensure the gasket is positioned correctly.
  2. Place the floodlight unit onto the mounting plate as shown in the sketch.
  3. Align the unit and securely fasten it with screws.

Beam Direction Adjustment:

Undo the joint screw using a hexagon socket head wrench size 6 mm to set the desired beam direction. Tighten the joint screw with a torque of 12 Nm.
Note: Do not remove the desiccant bag from the luminaire housing as it is necessary to remove residual moisture.

FAQ:

Q: Can I replace specific parts of the product?
A: Yes, you can replace spare parts such as spare glass with frame, LED power supply unit, LED module, reflector, gasket mounting box, and gasket housing. Refer to the part numbers provided in the manual for ordering.

DIMENSION

BEGA-84446-Performance-Floodlight-RGBW-FIG- \(1\)

Instructions for use

Application

  • Performance floodlight for additive color mixing RGBW with mounting box.
  • We recommend the use of BEGA DALI system components.

Product Description

  • Luminaire made of aluminum alloy,
  • aluminum and stainless steel
  • BEGA Unidure® coating technology
  • Color graphite or silver
  • Safety glass with optical structure
  • The reflector surface is made of pure aluminum
  • BEGA Vortex Optics®
  • The rotation range of floodlight is 350°
  • Swivel range -90°/+90°
  • Mounting box with 2 fixing holes
  • ø 4.8 mm · 67 mm spacing
  • 2 cable entries for through-wiring of mains
  • supply cable ø 7-10.5 mm, max. 5 G 1.5@
  • Connecting terminal 2.5@ with plug connection
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • Complies with flicker requirements by IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable (DT8, RGBWAF, xy)
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK07
  • Protection against mechanical impacts < 2 joule
  • – Safety mark
  • – Conformity mark
  • Wind catching area: 0.06 m²
  • Weight: 3.3 kg
  • This product contains light sources of energy efficiency class(es) F

SPECIFICATION

Lamp

  • Module connected wattage 40.5 W
  • Luminaire connected wattage 45 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 35 °C
  • Module designation LED-1104/RGBW
  • Color temperature of the white LED 4000 K
  • Luminaire luminous flux 2239 lm
  • Luminaire luminous efficiency 49,8 lm / W

Lighting technology

  • Asymmetrical light distribution
  • Half beam angle 42/50°

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Installation

  • Undo the hexagon socket head screw (wrench size 3 mm) up to the stop and disassemble the mounting plate.
  • Pass the power connecting cable through the cable entry in the mounting plate. Note the position of application of the mounting plate “arrow down”.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied.
  • Establish the earth conductor connection at the terminal of the mounting plate marked with 1.
  • Make the electrical connection at the terminal marked L and N (plug-in device).
  • The terminals marked DA, and DA (plug-in device) are to be used for digital control purposes.
  • If these terminals are not used, the luminaire will operate at full light output.
  • Place the earth conductor plug connector from the luminaire housing onto the mounting plate.
  • Then press both plugs (L, N and DA, DA) firmly into the plug-in devices of the mounting plate.BEGA-84446-Performance-Floodlight-RGBW-FIG- \(4\)
  • Make sure that the gasket is positioned correctly.
  • Place the floodlight unit onto the mounting plate as displayed in the sketch, and align and screw together firmly.

Adjustment of beam direction:

  • Undo the joint screw (hexagon socket head wrench size 6 mm) and set the desired beam direction.
  • Tighten the joint screw.
  • Torque = 12 Nm.

Cleaning Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the
  • LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.
  • Tighten grub screws (wrench size 3 mm) evenly.
  • Torque = 2.5 Nm.

Spares

  • Spare glass with frame graphite 25 000 145
  • Spare glass with frame silver 25 000 146
  • LED power supply unit DEV-0357/225
  • LED module LED-1104/RGBW
  • Reflector 76 001 550 .A
  • Gasket mounting box 83 001 839
  • Gasket housing 83 001 981

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals