Specifications
- Power Consumption of 84 847 : 0.05 A
- Lamp Module Connected Wattage: 8.1 W
- Luminaire Connected Wattage: 9.6 W
- Rated Temperature (ta): 25°C
- Ambient Temperature (ta max): 50°C
- Colour Temperature: LED-0800/930 3000 K
- Colour Rendering Index (CRI): > 90
- Module Luminous Flux : 1255 lm
- Luminaire Luminous Flux : 960 lm
- Luminaire Luminous Efficiency : 100 lm/W
Product Usage Instructions
Safety
The installation and operation of this luminaire must comply with national safety regulations. The manufacturer is not liable for damage due to improper use or installation.
Installation
- Unscrew the hexagon socket screws on the sides of the connection adapter using a 3 mm wrench.
- Screw the corresponding accessory to the floodlight with a torque of 5 Nm.
- Plug the floodlight’s connecting cable into the plug contact of the country-specific mains plug or distribution box.
- Ensure a connecting cable length of not more than 50 m per luminaire.
- To adjust the beam direction, undo the joint screw with a 5 mm wrench, set the desired direction, and tighten the screw with a torque of 7 Nm.
Maintenance
Check the connecting cable for external damage regularly and replace it only with the help of a qualified electrician.
Note
Do not remove the desiccant bag from the luminaire housing as it is essential for removing residual moisture.
Accessories
The following combination options are available for fitting to floodlights with connection adapter:
- 71 118 Shield
- 71 120 Exchangeable lens flat beam
FAQ
- Q: Can I use this luminaire outdoors?
- A: Yes, this luminaire can be used outdoors, but make sure tofollow all safety guidelines and protection against environmental elements.
- Q: How often should I check the connecting cable for damage?
- A: It is recommended to check the connecting cable for damage regularly, at least once every few months, to ensure safe operation.
Performance floodlight BEGA UniLink
Instructions for use
Application
Performance floodlight BEGA UniLink® with connection adapter for use in
combination with various accessories, e.g. for mounting on trees, pipes or
wooden structures.
A separate mains plug must be ordered in order to connect the floodlight to
the mains. The various country-specific mains plug with 0.5m connecting cable,
as well as extension cables and five-way distribution boxes are available as
accessories.
Product Description
- Luminaire made of aluminum alloy, aluminum and stainless steel
- BEGA Unidure® coating technology
- Clear safety glass
- Silicone gasket
- The reflector surface made of pure aluminium
- Optical silicone lens · BEGA Hybrid Optics®
- The rotation range of floodlight is 360°
- Swivel range -40°/+75°
- 5m mains supply cable
- X05RN-F FEP 2×1@ + 1G2,5@ with
- BEGA UniLink® plug-in connector
- Complies with flicker requirements in accordance with IEEE 1789,
- DIN IEC/TR 63158, DIN IEC/TR 61547-1
- LED power supply unit
- 220-240V 50-60 Hz
- BEGA Thermal Switch®
- Temporary thermal shutdown to protect
- temperature-sensitive components
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets
- Impact strength IK08
- Protection against mechanical
- impacts < 5 joule
- – Conformity mark
- Weight: 2.2 kg
- This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.The manufacturer accepts no liability for damage caused by
improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Total load
When configuring your lighting system, please ensure that the maximum power consumption of 6A is not exceeded. Information on power consumption can be found in the instructions for use and data sheets for all BEGA UniLink® luminaires.
Power consumption of 84 847 : 0,05 A
Lamp
- Module connected wattage : 8.1 W
- Luminaire connected wattage : 9.6 W
- Rated temperature: ta=25 °C
- Ambient temperature: ta max=50 °C
84 847K3
- Module designation: LED-0800/930
- Colour temperature: 3000 K
- Colour rendering index : CRI >90
- Module luminous flux : 1255 lm
- Luminaire luminous flux :960 lm
- Luminaire luminous efficiency : 100 lm/W
84 847K4
- Module designation :LED-0800/940
- Colour temperature :4000 K
- Colour rendering index : CRI >90
- Module luminous flux : 1275 lm
- Luminaire luminous flux :975 lm
- Luminaire luminous efficiency: 101,6 lm/W
Light technique
- Symmetrical wide beam light distribution
- Half beam angle 46°
- For special lighting applications, the symmetrical light cone can be changed to a flat beam using an additional diffuser lens.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Caution:
The BEGA UniLink® plug connectors may only be connected and disconnected in a voltage-free state.
Installation
Unscrew the hexagon socket screws (wrench size 3 mm) on the sides of the
connection adapter and screw the corresponding accessory to the floodlight.
Torque = 5Nm.
Plug the floodlight’s connecting cable into the plug contact of the connecting
cable with the country-specific mains plug, or into the distribution box or
extension cable.
To ensure a sufficiently low protective conductor resistance (loop
resistance), the connecting cable of each luminaire in the system must not
exceed a length of 50m from the entry point.
Adjustment of beam direction:
- Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
- Tighten the joint screw.
- Torque = 7Nm.
Please note:
- Do not remove the desiccant bag from the luminaire housing.
- It is needed to remove residual moisture.
Cleaning · Maintenance
- Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high-pressure cleaners.
Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.
Replacing the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light color and light output of BEGA replacement modules correspond to those
- of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
- Disconnect the system.
Open the floodlight:
- Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight housing.
- Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise.
- Replace LED module.
- Please follow the installation instructions for the LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- The defective glass must be replaced.
- Place trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top to each other.
- Twist on the trim ring clockwise as far as the stop. Tighten the locking pin.
Accessories
The following combination options are available for fitting to floodlights with connection adapter:
- 71 223 Screw clamp with connection adapter 71 224 Tube clamp with connection adapter 71 225 Lashing strap with connection adapter 71 226 General fastener with connection adapter
- 71 227 G½ mount with connection adapter
- 71 118 Shield
- 71 120 Exchangeable lens flat beam Country-specific mains plugs with 0.5 m connecting cable
- 71 180 Plug type F / E: system common in Germany and Europe
- 71 181 Plug type G: system used in Great Britain (“Commonwealth plug”)
- 71 182 Plug type J: system common in Switzerland and Liechtenstein
- 71 183 Plug type L: system common in Italy and Greece
- 71 184 Plug type K: system common in Denmark and Greenland
- 71 186 BEGA UniLink® Extension cable 5 m 71 187 BEGA UniLink® Extension cable 10 m 71 188 BEGA UniLink® Extension cable 20 m
- 71 247 Connecting cable 5 m with free line ends
- 71 256 Connecting cable 0.5 m with free line ends
- 71 189 BEGA UniLink® Five-way distribution box
For the accessories, separate instructions for use can be provided upon request.
Spares
- Spare glass with frame with glass
- Spare glass with frame with glass LED power supply unit
- LED module 3000 K
- LED module 4000 K
- Reflector
- Gasket housing
- Gasket trim ring