BEGA 33019K3 Shielded Luminaire Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
33019K3 Shielded Luminaire
Instruction Manual
33019K3 Shielded Luminaire
Technical amendments reserved
Recessed luminaire
Instructions for use
Application
Shielded luminaire for walls and stairs.
Product description
Luminaire made of aluminium alloy,
aluminium and stainless steel
BEGA Tricoat® coating technology
Matt safety glass
Fixing is achieved by using two adjustable wedge-shaped claws
Required recessed opening 306 x 60 mm
Recessed depth 70 mm 2 cable entries for through-wiring of mains supply cable
ø 7-10.5 mm
Connection terminal 2.5◻
Earth conductor connection
BEGA Ultimate Driver®
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-280 V
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK08
Protection against mechanical impacts < 5 joule
– Safety mark
**** – Conformity mark
Weight: 1.0 kg
This product contains light sources of energy efficiency class(es) C
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
Lamp
Module connected wattage | 3.2 W |
---|---|
Luminaire connected wattage | 4.1 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 60 °C |
When installed in heat-insulating material | ta max = 55 °C |
33 019 K3
Module designation | LED-1330/830 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 575 lm |
Luminaire luminous flux | 42 lm |
Luminaire luminous efficiency | 10,2 lm / W |
33 019 K4
Module designation | LED-1330/840 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 605 lm |
Luminaire luminous flux | 45 lm |
Luminaire luminous efficiency | 11 lm / W |
Please note:
This luminaire is coated with BEGA Tricoatb.BEGA Tricoatb is a registered
trademark for a technology that we use to achieve optimal corrosion
resistance.
Even the best possible surface protection and the highest corrosion resistance
can be rendered almost ineffective in some cases by aggressive media caused by
leaching of building materials.
Where such media are suspected, a material analysis must be carried out before
installation.
Always avoid excessive use of chemical cleaning agents in the vicinity of the
luminaire.
Installation
The recessed opening will be covered by the frame of the luminaire housing.
Fixing of the luminaire is achieved by using two adjustable wedge-shaped
claws.
Installation in solid, plastered walls:
The installation housing 10 426 is available for this purpose. If this is not
used, an exact recessed opening of 306 x 60 mm with a minimum depth of 70 mm
is required.
Installation in exposed brickwork:
The construction of an on-site recessed opening with the exact installation
dimensions of 306 x 60 mm with a minimum depth of 70 mm is required. An
installation housing cannot be used.
Installation in drywalling:
A recessed opening of 306 x 60 mm with a minimum depth of 70 mm is required.
The claws grip behind drywall.
Installation into insulated façades:
For installation in EWIS external wall insulation systems pleaseuse
installation housing 13 521 in combination with a plaster frame 10 026 or 13
505.
Open luminaire:
Undo hexagon socket screws (SW 3) and remove housing cover.
Disconnect plug-connection of the LED connecting cable.
Disconnect the earth conductor connection from the plug connection.
Lead the mains supply cable through the cable entry into the luminaire
housing.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
In order to guarantee the maximum service life of the electrical components,
the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the
position marked by the red information label immediately before finally
closing the luminaire.
Connect the LED connection cable by means of a plug connector.
Put on earth conductor connection of the housing cover. Assemble housing
cover.
Make sure that gasket is positioned correctly.
Tighten the screws evenly.
Insert luminaire housing into the recessed opening. Hand-tighten screws of the
claw fastener (torx drive T10) evenly. Do not use an electric screwdriver!
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Accessories
10 426 | Installation housing |
---|---|
13 521 | Installation housing for installation in insulated façades (EWIS) |
10 026 | Plaster frame |
13 505 | Plaster frame flush |
A separate instructions for use can be provided upon request.
Spares
LED power supply unit | DEV-0448/150 |
---|---|
LED module 3000 K | LED-1330/830 |
LED module 4000 K | LED-1330/840 |
Gasket | 83 001 955 |
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>