Specifications

  • Lamp Module connected wattage: 55.5 W
  • Connected luminaire wattage: 60 W
  • Color temperature: 3000 K (K3), 4000 K (K4)
  • Color rendering index (CRI): > 90
  • Module luminous flux: 5985 lm (K3), 6490 lm (K4)
  • Luminous flux: 4095 lm (K3), 4440 lm (K4)
  • Luminaire luminous efficiency: 68.2 lm/W (K3), 74 lm/W (K4)
  • Safety class: I
  • Protection class: IP 65

Product Usage Instructions

Facility

  1. Installation and commissioning must be done by a qualified electrician.
  2. Ensure the luminaire is mounted securely on a wall, ceiling, or pillar using the mounting box provided.
  3. Connect the luminaire to the power supply according to the manufacturer’s instructions.

Operation

  1. Ensure the luminaire is connected to a suitable power source within the specified voltage range.
  2. Control the luminaire using DALI control if applicable, keeping in mind the number of DALI addresses.
  3. Monitor the ambient temperature to ensure it is within the specified limits for proper operation.

Maintenance

  1. Regularly clean the luminaire and check for any signs of damage.
  2. If any modifications need to be made, ensure they are carried out by qualified personnel.

FAQs

  • Q: What should I do if the luminaire is not working?
    A: Check the power supply and connections to ensure proper functionality. If issues persist, contact a qualified electrician for further assistance.

  • Q: Can the luminaire be used in outdoor settings?
    A: Yes, the luminaire has an IP 65 protection class, making it suitable for outdoor use with protection against dust and water jets.

Compact downlight with minimal diffuse light percentage

DIMENSION

BEGA-85-082-Compact-Downlight-FIG- \(1\)

Instructions for use

Application

  • Compact floodlight with mounting box for permanent installations on a wall, under a ceiling or on a pillar.
  • BEGA Ultradark Optics® offer a maximum of illumination and eye comfort due to a minimised diffuse light percentage and highly efficient glare suppression.

SPECIFICATION

Lamp

  • Module connected wattage: 55.5 W
  • Luminaire connected wattage 60 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C

85 082 K3

  • Module designation: LED-1263/930
  • Color temperature: 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 5985 lm
  • Luminaire luminous flux 4095 lm
  • Luminaire luminous efficiency 68,2 lm / W

85 082 K4

  • Module designation LED-1263/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 6490 lm
  • Luminaire luminous flux 4440 lm
  • Luminaire luminous efficiency 74 lm / W

Lighting technology

  • Symmetrically focused wide beam light distribution with minimal diffuse light percentage.
  • Half beam angle 25°

Safety

  • The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Product description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite or silver
  • Matt safety glass
  • Internal louvres and polymer lens
  • BEGA Ultradark Optics®
  • Louvres and interior surface of anti-glare ring with maximum light-absorbing ultra-black nano-coating
  • Rotation range of floodlight 350°
  • Swivel range -20°/+90°
  • Mounting box with 2 fixing holes
  • ø 6 mm · 85 mm spacing
  • 2 cable entries for through-wiring of mains
  • supply cable ø 7-10.5 mm, max. 5 G 1.5@
  • Connecting terminal 2.5@
  • with plug connection
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • Complies with flicker requirements in
  • accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK07
  • Protection against mechanical impacts < 2 joule
  • – Safety mark
  • – Conformity mark
  • Wind catching area: 0.058 m²
  • Weight: 5.0 kg
  • This product contains light sources of energy efficiency class(es) F

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Please note:
Contact with the inner surface of the luminaire reflector should be avoided in order to permanently protect the special stray lightminimising properties of the nano-coating.

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

  • Undo hexagon socket head screws (wrench size 3 mm) at the mounting box and remove mounting plate.

  • Pass the power connecting cable through the cable entry in the mounting plate.

  • Note position of application of the mounting plate “arrow down”.

  • Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.

  • Be sure to use the gasket rings supplied.

  • Make earth conductor connection.

  • Push silicone sleeves over the lines and make electrical connection to terminal (plug connection).

  • For digital control please use the 2-pole plug connector DA, DA.

  • In case this connector is not used the luminaire will be operated at full light output.

  • Push plug into coupler as far as it will go.

  • Make sure that gasket is positioned correctly.
    BEGA-85-082-Compact-Downlight-FIG- \(4\)

  • Place floodlight unit onto the mounting plate as displayed in the sketch, align and screw together firmly

Adjustment of beam direction:

  • Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
  • Tighten the joint screw.
  • Torque = 7 Nm.

Cleaning Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners

Maintenance
The connecting cable between mounting box and floodlight has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by a qualified person using commercially available tools.
  • Disconnect the system from the power supply. Open the floodlight:
  • Loosen the back locking pin (hexagon socket wrench size 2) in the trim ring.
  • Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise. Please note:
  • Contact with the inner surfaces of the louvres and luminaire reflector should be avoided in order to permanently protect the special stray light-minimising properties of the nano-coating. Grasp the louvres from the outside and lift them out. Loosen the three mounting screws (Torx drive
  • T20) and lift the lens holder (with the loosely inserted lenses) upward horizontally out of the housing.
  • Replace LED module.
  • Please follow the installation instructions for the LED module.
  • Install in reverse order.
  • When installing the lens holder, make sure that the LED connecting cable is not pinched. Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
  • Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.

Accessories

  • 71 282 Shield
  • 71 287 Cylindrical shield

For the accessories a separate instructions for use can be provided upon request.

Spares

  • Trim ring graphite with glass 25 000 236
  • XSTrim ring silver with glass 25 000 237
  • LED power supply unit DEV-0356/1400i
  • LED module 3000 K LED-1263/930
  • LED module 4000 K LED-1263/940
  • Gasket mounting box 83 001 838
  • Gasket trim ring 83 002 145
  • Gasket housing 83 002 225

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals