Instructions for use

Application
Performance floodlight BEGA UniLink® with connection adapter for use in combination with various accessories, e.g. for mounting on trees, pipes or wooden structures. A separate mains plug must be ordered to connect the floodlight to the mains. The various country-specific mains plug with 0.5m connecting cable, as well as extension cables and five-way distribution boxes are available as accessories.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite or silver
  • Clear safety glass
  • Silicone gasket
  • The reflector surface is made of pure aluminium
  • Optical silicone lens · BEGA Hybrid Optics
  • The rotation range of floodlight is 360°
  • Swivel range -40°/+75° 5m mains supply cable
  • X05RN-F FEP 2×1+ 1G2,5 with
  • BEGA UniLink plug-in connector
  • Complies with flicker requirements by IEEE 1789
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit220-240 V y 50/60 Hz
  • BEGA Thermal Switch
  • Temporary thermal shutdown to protect
  • temperature-sensitive components
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK06
  • Protection against mechanical
  • impacts < 1 joule
  • Conformity mark
  • This product contains light sources of energy efficiency class(es) E

Safety
The installation and operation of this luminaire are subject to national safety regulations. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Total load

  • When configuring your lighting system, please ensure that the maximum power consumption of 6A is not exceeded.
  • Information on power consumption can be found in the instructions for use and data sheets for all BEGA UniLink® luminaires.
  • Power consumption of 85 173: 0,12 A

Lamp

  • Module connected wattage 24.1 W
  • Luminaire connected wattage 27 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=30 °C

85 173K3

  • Module designation LED-0800/930
  • Colour temperature 3000 K
  • Colour rendering index CRI >90
  • Module luminous flux 3350 lm
  • Luminaire luminous flux 2472 lm
  • Luminaire luminous efficiency 91,6 lm/W

85 173K4

  • Module designation LED-0800/940
  • Colour temperature 4000 K
  • Colour rendering index CRI >90
  • Module luminous flux 3400 lm
  • Luminaire luminous flux 2509 lm
  • Luminaire luminous efficiency 92,9 lm/W

Lighting technology

  • Symmetrical wide beam light distribution
  • Half beam angle 45°
  • For special lighting applications, the symmetrical light cone can be changed to a flat beam using an additional diffuser lens.

Caution
The BEGA UniLink® plug connectors may only be connected and disconnected in a voltage-free state.

Installation

  • Unscrew the hexagon socket screws (wrench size 3 mm) on the sides of the connection adapter and screw the corresponding accessory to the floodlight.
  • Torque = 5Nm.
  • Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug or into the distribution box or extension cable.
  • To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50m from the entry point.

Adjustment of beam direction

  • Undo the joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
  • Tighten the joint screw.
  • Torque = 7Nm.

Cleaning · Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.

Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Please note

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module
The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module. The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools. Disconnect the system.

Open the floodlight

  • Undo the locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight housing.
  • Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise.
  • Replace the LED module.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • The defective glass must be replaced.
  • Place the trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top of each other.
  • Twist on the trim ring clockwise as far as the stop. Tighten the locking pin.

Accessories

The following combination options are available for fitting to floodlights with connection adapter

  • 71 223 Screw clamp with connection adapter
  • 71 224 Tube clamp with connection adapter
  • 71 225 Lashing straps with connection adapter
  • 71 226 General fasteners with connection adapter
  • 71 227 G½ mount with connection adapter
  • Shields and diffuser lenses that alter the light distribution are available as accessories for these floodlights.
  • 71 290 Exchangeable lens flat beam
  • 71332 Shield
  • 71 335 Cylindrical shield
  • Country-specific mains plug with 0.5m connecting cable71180
  • Plug type F / E: system common in Germany and Europe
  • 71181 Plug type G: system used in Great
  • Britain (“Commonwealth plug”)
  • 71182 Plug type J: system common in
  • Switzerland and Liechtenstein
  • 71183 Plug type L: system common in Italy and Greece
  • 71184 Plug type K: system common in
  • Denmark and Greenland
  • BEGA UniLink® extension cables with socket and plug
  • 71 186 BEGA UniLink® Extension cable 5m
  • 71 187 BEGA UniLink® Extension cable 10m
  • 71 188 BEGA UniLink® Extension cable 20m
  • BEGA UniLink® connecting cables with a plug connector and one free cable end to connect to e.g. a conventional connection box
  • 71 247 Connecting cable 5m with free-line ends
  • 71 256 Connecting cable 0.5m with free-line ends

BEGA UniLink distribution box with five connection sockets for the connection of BEGA UniLink luminaires, extension cables or additional five-way distribution boxes 71 189 BEGA UniLink Five-way distribution box For the accessories separate instructions for use can be provided upon request.

Spares

  • Trim ring graphite mit Glas 25 000 277
  • Trim ring silver mit Glas 25 000 278
  • LED power supply unit DEV-0352/700
  • Connecting cable 62 000 877
  • LED module 3000 K LED-0800/930
  • Reflector 75 005 075
  • Gasket housing 83 000 521
  • Gasket trim ring 83 001 952

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · [email protected] · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals