LUMENESSA LS101 IPL Hair Removal Device
Lumenessa Hair Removal Device is designed to remove unwanted hair easily and comfortably at home. It uses Intense Pulsed Light (IPL) technology to target melanin inside hair follicles, destroy the hair follicle, and disrupt its growth cycle, thereby preventing hair regeneration effectively.
Working Principle
The Lumenessa Hair Removal Device emits an intense pulse of light wave that penetrates the surface layer of the skin to destroy the hair follicle and disrupt its growth cycle, preventing hair regeneration.
Device Overview
- Standard head
- Precision head
- Skin tone sensor
- Camera window
- Treatment window
- Glass filter integrated UV filter
- Treatment button
- Intensity lights(1-5)
- LED energy indicator light
- Air vents
- Power Cable
- Base station
Contraindications
Do not use the Lumenessa Hair Removal Device if you have skin type VI, or sensitivity to light. This can lead to discomfort/pain and adverse reactions such as burns, blisters, abnormal skin color, or scarring, causing damage to your skin health.
Precautions and Warnings
To ensure safe use, please read the instructions carefully before using the product. Use the appropriate treatment head for each body part. Do not use Lumenessa to treat your eyebrows. When treating the area above the upper lip, be careful not to flash onto your lips. When treating light-sensitive areas, use the low-energy mode. Using the standard care head in combination with the precision care head will make the treatment process easier and more convenient.
Getting Started
Before using the Lumenessa Hair Removal Device, please read the instructions carefully, including all contraindications, warnings, and safety information. To ensure safe use, Lumenessa is equipped with a skin tone sensor that measures your skin tone before each treatment. If the sensor detects that your skin color is too dark and unsuitable for use, the device’s red LED indicator will remain on, which means that even if you press the flash button, the device will not emit light.
Treatment Intervals
To achieve smooth and flawless skin as soon as possible, we recommend using Lumenessa Hair Removal Device once every two weeks for the first four treatments. After that, use it once every four weeks for maintenance.
Camera
The camera allows you to see the growth of hair on the skin surface before and after treatment, making it easier for you to understand the growth cycle of the treatment areas. For operating instructions of the camera function, please visit the official website www.Lumenessa.com or contact customer service.
Welcome
Welcome to the beauty world of Lumenessa! This product uses Intense Pulsed Light (IPL) technology, which allows you to easily and comfortably remove unwanted and visible hair at home. Before using the product, please read the instructions carefully, including all contraindications, warnings, and safety information.
Please keep this carefully for future reference
Working Principle
Lumenessa Hair removal devices target the melanin inside hair follicles. An
intense pulse of light wave is emitted and penetrates through the surface
layer of the skin, destroying the hair follicle and disrupting its growth
cycle, thereby effectively preventing hair regeneration
Device overview
- Standard head
- Precision head
- Skin tone sensor
- Camera window
- Treatment window
- Glass filter(integrated UV filter) 7 Treatment button
- Intensity lights(1-5)
- LED energy indicator light
- Air vents
- Power Cable
- Base station
Contraindications
Do Not Use If You Have Any Of The Following
Medical Conditions
Never use the device if you have skin type VI.In this case, more light energy will be absorbed by the skin, leading to discomfort/pain and adverse reactions (such as burns, blisters, abnormal skin color or scarring), causing damage to your skin health
-
Pregnant or breastfeeding women and children under the age of 15 should not use this device.
Note : teenagers between the ages of 15-18 must use this device with adult supervision. -
The skin that has been tanned naturally or artificially using light therapy should not be treated with this device immediately.
Note : Tanning affects skin sensitivity and color. Please wait at least 2 weeks and perform a skin color test before using. Occasional and indirect exposure to sunlight does not count as tanning. -
After using this device, please avoid direct sun exposure without protection (such as applying SPF30+ sunscreen).
-
Do not use this device on infected, eczematous, inflamed hair follicles, burned, scraped, damaged skin or abnormal skin color.
Note : moles,freckles, and darker pigmentation are considered abnormal skin color. Sunburns, cuts, active infections, and other open wounds are considered damaged skin. -
Do not use this device on skin that is sensitive to light and easily develops rashes or allergic reactions.
Medication/History
Do Not Use If You Have Any Of The Following
Medical Conditions
- If you have previously had diseases that suppress immune responses (including HIV infection and AIDS)
- If you are using photosensitive drugs (such as tretinoin, isotretinoin, and/or other topical retinoids)
- If you are taking heat-sensitive painkillers
- If you have varicose veins in the area being treated
- If you have chronic skin diseases (such as psoriasis or vitiligo)
- If you have undergone surgery on the treated area within the last 3 weeks
- If you have received radiation therapy or chemotherapy in the past three months
Using this product under any of the above conditions may damage your skin, worsen your skin condition, or cause adverse reactions such as burns, blisters, excessive pigmentation or scars.
Note : If you are unsure whether it is safe to use this product, consult your doctor or dermatologist.
If you are taking medication for a long time, consult your doctor about the possible effects of these medications on skin sensitivity to light.
Precautions:
- Do not use it while bathing or showering.
- Do not touch any internal components of the device when it is damaged to avoid electric shock.
- Do not block the ventilation slots, otherwise, it may cause overheating of the product and increase the risk of electric shock or fire.
- Do not wash with water. Do not immerse the device in water.
- If the care head and filter of the device are damaged due to impact, shaking or falling, please do not use it again.
- Before use, please check whether the power cord of this device is intact. If there is obvious damage and breakage, please do not use it again.
- Never insert anything into the device.
For any issues related to product damage, please go to the Lumenessa after- sales service center for repair.Unauthorized repairs may cause great danger to you. After each use, please unplug the plug.
Warning
- Before using the device, be sure to perform a light intensity test and select the appropriate light intensity for your skin. Note: Please refer to the “Choosing the Right Light Intensity”
- chapter for testing methods.
- The device and accessories must be kept dry.
- It is recommended that this product be used by one person only.
- Do not use this product near water-filled bathtubs, showers, basins, or other containers.
- Do not use this device on the following areas: Around the eyes and above or near the eyebrows. Lips, nipples, genitalia, or perianal area. Tattoo or permanent makeup areas.
- Do not look directly at the filter lens or start the product towards the eyes. To ensure your safety and that of those around you, this product only works when the care head skin sensor is in full contact with the skin. If the product can be started and irradiated without the sensor touching the skin, please stop using it immediately and contact the retailer.
- Do not use this product more than twice a week in the same area.
- People with physical disabilities, sensory or mental disorders must use this device under the supervision and guidance of someone who is responsible for their safety.
- Do not use corrosive liquids to clean this device.
Getting Started
Treatment Intervals
Initial treatment
When performing the first 4-5 treatments, it is recommended to use it once every two weeks to ensure that all hair is treated
Trimming stage
After the initial treatment phase (4-5 treatments), if you notice hair regrowth, it is recommended to trim it every 4-8 weeks. This is to maintain the effect and keep the skin smooth for months. The interval between treatments can be adjusted according to individual hair growth rates and different body parts
Note:
The treatment cycle and frequency are determined by the user’s hair growth
cycle, and some may even require long-term care for up to 16 months.
The camera function of this device can effectively help you retain images of
the treatment process to analyze and compare, determining the treatment cycle
and frequency for each area that needs to be treated, thus helping you achieve
smooth and flawless skin as soon as possible
Skin tone sensor
To ensure safe use, Lumenessa is equipped with a skin tone sensor that measures your skin tone before each treatment. If the sensor detects that your skin color is too dark and unsuitable for use, the device’s red LED indicator will remain on, which means that even if you press the flash button, the device will not emit light
Treatment head
To achieve the best results and safety, it is essential to select the appropriate treatment head for each body part. To meet the needs of different areas of the body, Lumenessa provides an additional attachment (precision head)
To install the precision head, simply press it onto the standard head. To remove the precision head, simply pull it off from the standard head.
Standard head
The standard head is installed at the factory and should not be dismantled by users. The standard head has the largest irradiation window, which can effectively cover and treat body parts below the neck, especially large areas such as legs, arms, and abdomen
Precision head
The precision care head has a precise curved design for safe and accurate treatment of sensitive skin areas such as chin, underarms, and bikini line.
Warning:
- Do not use Lumenessa to treat your eyebrows.
- When treating the area above the upper lip, be careful not to flash onto your lips.
- When treating light-sensitive areas, use the low-energy mode.
- Using the standard care head in combination with the precision care head will make the treatment process easier and more convenient
Camera
The camera allows you to see the growth of hair on the skin surface before and
after treatment, making it easier for you to understand the growth cycle of
the treatment areas.
Note:
For operating instructions of the camera function, please visit the official
web www.Lumenessa.com or contact customer service.
Before you use your Lumenessa
Pretreating your skin
- Before using Lumenessa, you should remove any excess hair from the surface of the skin. Please choose a comfortable method to remove hair and ensure that the skin is clean without any oily substances.
Note : If shaving causes skin allergies, it is recommended to use this device only after the skin allergy has healed
To start the device
- Connect one end of the power cord (11) to the power base (12), and plug the other end into a power outlet. The fan will start and the first gear energy indicator light will stay on, indicating that the device has started.
This product will generate some heat while in operation Energy Level and
Indicator Light Definitions
Two Treatment Modes: Stamping & Gliding
Lumenessa has two treatment modes, which makes it more convenient for different body parts:
- The stamping mode is suitable for various parts, and is particularly convenient for smaller or curved areas such as knees and armpits. Simply press and release the treatment confirmation button to emit a flash.
- The sliding flash mode is convenient for larger areas such as legs. While sliding the device on the skin, hold down the flash button to emit consecutive flashes
Note : The minimum interval between two flashes emitted by the device is approximately 0.6 seconds (maximum 1.6 seconds), and mastering the flash time can ensure that each desired area is treated. Sliding too fast on the skin may cause some areas to be missed
Using your Lumenessa
For the first use of Lumenessa, a skin test should be performed on each area
to be treated. The purpose of the skin test is to check for any reactions to
the treatment and determine the correct light intensity setting for each body
part. Note: After the skin test, wait for 24 hours and confirm that there are
no adverse reactions before using this device
Choosing The appropriste Energy Level
Lumenessa provides you with 6 different light intensities, and you can choose
the appropriate one for your skin condition and comfort level during
treatment.
-
After the device is correctly connected, it will be in standby mode.
-
Place the device at a 90-degree angle on the skin to be treated, making sure it is in good contact with the skin.
-
Once the device makes reliable contact with the skin, it will perform a skin color analysis. When the “ready to flash” indicator light turns green, it indicates that treatment can begin.
Note : If the skin color is too dark, the “ready to flash” indicator light will turn red, and the device will not operate. You can try using it on other lighter areas. -
Use levels 1-6 to flash different parts of the skin in the same area, record the results after flashing, and observe the condition of the treated skin after 24 hours. Choose the most suitable intensity level for treatment.
Note : Different body parts such as thighs, armpits, face, and bikini have different hair states and require different light intensities.
Distinct areas with different skin colors should be tested separately for light intensity.
When conducting the test, start from low-level intensity and move up gradually. If there is significant pain or discomfort, stop testing higher levels immediately. -
If severe redness or burns appear on a tested area of the skin within 24 hours, use another appropriate intensity level for treatment
Using the device
-
Please install the appropriate treatment head for the area to be treated. Refer to chapter 2 “Treatment Head” for instructions on how to start the device and choose the appropriate intensity level.
Reference: “To start the Device” section. -
Place the device at a 90-degree angle on the skin, making contact with the treatment head and the skin. The treatment head can prevent accidental flashing when it is not in contact with the skin
-
Place the device tightly against the skin to ensure proper contact. When the “ready to flash” indicator light on the side of the device turns green, it indicates that you can begin treatment
-
Press the flash button to emit a flash. The device will make a slight popping sound, and you may feel a slight warmth due to the flashing.
Note : The scattered light emitted by this device is harmless to the eyes. Do not look directly at the flash while using it. No need to wear it during use -
Place the device on the next area to be treated. After each flash, the device needs 0.6-1.6 seconds to emit another flash. When the “ready to flash” green light turns on, the product can emit light.
Note : In slide flash mode, the time interval between flashes may suddenly slow down. This is due to the continuous rapid flashing causing the temperature of the device to rise faster. When it exceeds our preset safe temperature value, the device will automatically increase the time interval between flashes to lower its temperature. This is a normal phenomenon -
To ensure that all areas are treated, flash on adjacent areas. The effective light can only be emitted through the emission window. Because the device component in contact with your skin is relatively large, there will be some overlapping radiation. However, please make sure to flash only once for the same area
-
After completing the treatment, please disconnect the device from the power outlet
After treatment
Common skin reactions
Your skin may experience slight redness and/or feel itchy, tingly, or warm.
This reaction is completely harmless to the body and will quickly disappear.
Dryness and itching of the skin may occur when shaving or combining IPL hair
removal with shaving. You can use ice packs or damp towels to cool the
affected area. If dryness persists, you can apply an unscented moisturizer to
the treated area
Rare side effects
- Burns, severe redness (e.g. near hair follicles) and swelling: These reactions are extremely rare and are caused by using light intensity that is too high for the skin color. If these reactions do not disappear within three days, it is recommended that you consult a doctor. Please wait until the skin has healed before undergoing a second treatment, and ensure that a lower light intensity is used.
- Skin discoloration: This phenomenon is very rare. Skin discoloration usually appears darker (hyperpigmentation) or lighter (hypopigmentation) than the surrounding area. This is caused by using a light intensity that is too high for the skin color. If skin discoloration persists for more than two weeks, it is recommended that you consult a doctor. Please wait until the skin returns to its normal color before treating the discolored area again.
- Skin infection is extremely rare, but may occur after (minor) injuries, burns, or allergic reactions.
- Epidermal heat (clear-edged brown area, usually darker and without skin dryness): This phenomenon is very rare. If epidermal heat persists for more than a week, it is recommended that you consult a doctor. Please wait until the skin has healed before undergoing a second treatment, and ensure that a lower light intensity is used.
- Blistering (appearing as small bubbles on the surface of the skin): This phenomenon is very rare. If blistering does not disappear within one month, or if further skin infection occurs, it is recommended that you consult a doctor. Please wait until the skin has healed before undergoing a second treatment, and ensure that a lower light intensity is used.
- Scarring: Usually an adverse effect from skin burns, it may take at least a month to heal.
- Folliculitis (swelling around the hair follicles with pus): This phenomenon is very rare and is usually caused by bacteria entering damaged skin. If this happens, it is recommended that you consult a doctor, as treatment of folliculitis may require antibiotic cream.
- Extreme pain: If you use this device on unshaved skin, or use light intensity that is too high for your skin color, or flash multiple times in the same skin area, or use the device on open wounds, inflammation, infection, tattoos, or burns, there may be extreme pain during or after irradiation.
Post-Treatment Care
After treatment, you can safely apply lotion, cream, perfume, moisturizer, or
makeup to the treated area. If you experience skin allergies or redness after
treatment, wait until the symptoms disappear before applying beauty products
to your skin. If you experience skin allergies after applying beauty products,
rinse with water.
Note : Even if you follow all instructions, you may still experience skin
reactions. In this case, please stop using the device and contact your
country/region’s customer service center
Cleaning and Storage
- 15-90%After use, the device should be turned off, unplugged, and allowed to cool. Note: The emission window and accessories will become very hot after use.
- Dampen the soft cloth supplied with the device with a little water, and use it to clean the following components:
- The outer surface of the treatment head
- The reflector in the treatment head
- The skin tone sensor window
- Let all components dry thoroughly.
- Store this device in a dust-free place, at a temperature between -25°C and +70°C, with humidity between 15-90%.
Warranty And Support
For more information or support, please visit www.Lumenessa.com
Recycling
When disposing of this product, do not throw it away with ordinary household
waste. Please give it to a government-designated recycling center. This will
help protect the environment.
Lumenessa products contain recyclable materials and should not be classified
as urban waste. For recycling options, please refer to the Lumenessa support
website. Do not burn
Technical Specifications
rated voltage | 100-240 V |
---|---|
rated frequency | 50-60 HZ |
rated input | 130W |
Protection against electric
shock
| Class Ⅱ
Protections Class| IP 22 (EN 60529)
Operating conditions| temperature: 5°C to 35°C
Ralative humidity| 15% to 90% ( non
condensing)
---|---
Storage conditions
temperature
| -25° to 70℃
Storage conditions
humidity
| <90%(non condensing)
Maximum varation of the
light output over the treatment area
| <20%
Operating pressure| 700hPa-1060hPa
Duration of the pulsetrain| Single pulse/continuous
pulse
Emitted wavelengths| 200-1600nm
Optical exposure| 3.2-6.5J/cm²
Maximum optical energy| 10-19.5J
Optical homogeneity| Max.+/- 20% deviation from
average optical exposure in treatment area
Repetition time| 0.6-1.6s
Pulse duration| <10ms
Flash interal| 0.6-1.6s,depends on
Stamping and Sliding mode
Pulse sequence| Single pulse/continuous
pulse
---|---
Troubleshooting
The device/power supply will heat up during use| It is normal for the device and power supply to heat up during use (but not to the point of being hot to
the touch
| Please use the device in a cooler environment and/or wait for it to cool
down before continuing to use
---|---|---
| The fan is not working| Make sure the power plug is properly
connected
| Hand or towel is blocking the airflow of the
fan
| Make sure the airflow of the fan is not blocked
After placing the device on the skin, the
LED indicator
| The skin color of the area you are trying to
treat is too
| Please use
Lumenessa to treat other areas of your body with
light turns red | dark. | lighter skin tones |
---|---|---|
The side LED indicator light is not turning green | Device not fully in contact | |
with the skin | Place the device vertically at a 90-degree angle on the skin, |
so that the treatment head is in contact with
the skin
| You have not shaved the hair in the area to be treated well. These hairs may burn and emit an
odor.
| Please remove any hair on the skin before using Lumenessa
During the treatment, the skin may be more sensitive than usual.
Skin discomfort may occur
when using
| The light
intensity you are using is set too high
| Check if the light intensity setting you have selected is appropriate. Choose a lower setting if
necessary
this device| |
---|---|---
| You have not removed the hair in the area
to be treated
| Please remove any hair on the skin before using
Lumenessa
| Filter is
damaged
| Do not continue to use the device if the UV filter is damaged. Please contact Lumenessa customer service center, dealer or service center in your
country/region
| The depilated area is not suitable for
using this device
| Do not use this device in the following areas: inner labia, anus, nipples, areola,
lips, moles,
freckles, tattoos,
| | piercings, nostrils and inside the ears, around the eyes, and near the eyebrows. Men should not use this device on their face and neck (including all areas with long beards) or on the entire
genital area
---|---|---
Tags
FCC
Federal Communications Commission (FCC) Statement. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide Reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one ormore of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning : Changes or modifications made to this device not expressly approved by Lumenessa Corp may void the FCC authorization to operate this device.Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. RF exposure statement:
This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. The device is installed and operated without restriction.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>