ta : -20°C …+40°C

Tools

1007492| 220V – 240V—50/60Hz| 36W| 4250 Im| 3000K| CRI>80| 123,6 x 8 x 7,6 cm| 1,60 kg
---|---|---|---|---|---|---|---
1007493| 4470 Im| 4000K
1007494| 50W| 6150 Im| 3000K| 153,6 x 8 x 7,6 cm| 1,95 kg
1007495| 6640 Im| 4000K

  • 1007492
  • 1007493
  • 1007494
  • 1007495

Tools
Installation Instruction

Electric Shock Icon The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
Electric Shock Icon
The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional

Technical Details are subject to change

Operating Manual PART B Wall- and Ceiling Light

Read manual carefully and keep for further use! Safety advices for installation and operation. Disregard may lead to danger of life, burning or fire!

  • Any works on the electrical connection only by electrician.
  • Do not alter or modify the product.
  • Do not fasten anything on the product.
  • Do not cover the product.
  • Operate only with intact protection glass or protection cover.
  • Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
  • Take measures that children get not harmed by the product.
  • Do not stare into the active light source.
  • Additional safety advices=

Use as directed

  • Safety class I (1) – Connection with protective conductor.
  • Operate only firmly fixed on an even surface.
  • Operate only on normal or not inflammable surfaces.
  • Do not strain mechanically or expose to strong dirt contamination.
  • IP66 : Protection against dust (dust-tight) – Protection against strongly jetted water.
  • Admissible ambient temperature(ta): – 20°C …+40°C

Light Source
The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician or a comparable qualified person

Caution, danger of electric shock.
This product contains a light source of the energy efficiency class D.
1007492 …94:
Reference control setting : 3000K
1007493 …95:
Reference control setting: 4000K

Care / Storage

  • Disconnect product from mains and let it cool down.

  • Clean external surfaces regularly with a slightly moistened (water) cloth.

  • Do not clean with pressure washer.

  • Openings providing aeration or drainage must be kept free.
    The following influences may have unwanted effects on the product: acidic surrounding, high salt content  in the air, cleaning agents, fertilizer, thawing salt, chemicals.

  • Store dry and clean.

Installation

Switch off mains / fixed connection cable!
Use only described accessories. Use only suitable fastening materials. Only suited for wall and ceiling surface mounting.

Follow local regulations for outdoor installations. Do not seal the product yourself (e.g. with silicone). Install according to declared IP type. Install as shown in the figure.

Electrical connection

  • Direct the fixed wiring with its complete insulation at least 15 mm into the\ housing.
  • Equip flexible wire ends with suitable wire ferrules!
  • Live conductor___   Terminal L
  • Neutral conductor__   Terminal N
  • Protective conductor__   Earth terminal
  • Dali control wires __Terminals DA
  • Secure cable gland applying a suitable tool.
  • Use second cable gland for through-wiring.
  • Up to 15 luminaires may be connected in one row.

Check secure fixation and proper function!