SLV 1007679 Ceiling Light Instruction Manual

May 15, 2024
SLV

SLV 1007679 Ceiling Light Instruction Manual
SLV 1007679 Ceiling Light

Caution Icon The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!

The light source is not replaceable. The separate control unit is only exchangeable by a professional.
Replaceable

Operating Manual PART B Ceiling Light 1007679

Read manual carefully and keep for further use!
Safety advices for installation and operation.
Disregard may lead to danger of life, burning or fire!

Any works on the electrical connection only by electrician.

Do not alter or modify the product.

Do not fasten anything on the product.

Do not cover the product.

Operate only with intact protection glass.

The supply cord cannot be replaced when damaged. Do not operate the product with a damaged supply cord. In this case the complete product must be disposed.

Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.

Take measures that children get not harmed by the product.

Do not stare into the active light source.

Additional safety advice =

Use as directed

Safety class I (1) – Connection with protective conductor.
Operate only firmly fixed on an even surface.
Operate only on normal or not inflammable surfaces.
Operate only indoors.
Do not strain mechanically or expose to strong dirt contamination.
IP65: Protection against dust (dust-tight) – Protection against jetted water from all directions.
Admissible ambient temperature(ta): -40°C …+40°C.

Light Source

The light source of this luminaire is not replaceable. In case that the light source must be replaced (e.g. at the end of its lifetime) the whole luminaire needs to be replaced.
This product contains a light source of the energy efficiency class D.

Care / Storage

Disconnect product from mains and let it cool down.
Clean external surfaces regularly with a slightly moistened (water) cloth. Store dry and clean.

Installation

Switch off mains / fixed connection cable!
Use only described accessories.
Use only suitable fastening materials.
Only suited for ceiling surface mounting.
Install according to declared IP type.
Install as shown in the figure.

Electrical connection

Electrical connection
Equip flexible wire ends with suitable wire ferrules!
Protect the connection applying an IP 68 connection box or cable connector ( e.g. SLV 228730).
Suitable terminal block: 400V, 16A, Pole: 3
Live conductor: Conductor L
Neutral conductor : Conductor N
Protective conductor: Conductor (PE)

Check secure fixation and proper function!