Product Specifications

  • IP Rating: IP44
  • Input Voltage: 220V – 240V ~50/60Hz
  • Socket Type: GX53
  • Maximum Wattage: 11W
  • Dimensions: 19 x 75 x 19 cm
  • Weight: 3.30 kg

Installation

  1. Switch off mains/fixed connection cable before starting the installation.
  2. Use only the described accessories and suitable fastening materials for installation.
  3.  The luminaire is only suited for ground surface mounting.
  4. Follow local regulations for outdoor installations.
  5. Do not seal the product yourself with silicone.
  6. Install according to the declared IP type.

Electrical Connection

  1. Protect the connection using an IP 68 connection box or cable connector (e.g. SLV 228726).
  2. Ensure the terminal block meets the specifications: min. 400V, 16A, Pole: 3.
  3. Connect the Live conductor (L), Neutral conductor (N), and Protective conductor (PE) accordingly.
  4. Check for secure fixation and proper function after connection.

Care and Maintenance

  1. 1. Disconnect the product from mains and let it cool down before cleaning.
  2. Clean external surfaces regularly with a slightly moistened cloth. Do not use a pressure washer.
  3.  Ensure the base is not covered with any materials and keep aeration/drainage openings free.
  4. Avoid exposure to acidic surroundings, high salt content in the air, cleaning agents, etc.
  5. Store the product in a dry and clean place when not in use.

Frequently Asked Questions (FAQ):
Q: Can I use a higher wattage bulb than the specified maximum?
A: It is recommended to strictly adhere to the maximum wattage limit mentioned (11W) to avoid any damage to the luminaire.

INSTRUCTION MANUAL PART A Floor lamp

SLV-232294-Outdoor-Floor-Stand-Luminaire-1

SLV-232294-Outdoor-Floor-Stand-Luminaire-2 The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!

Operating Manual PART B Outdoor Floor Stand Luminaire 232294 …95

  • Read manual carefully and keep for further use!
  • Safety advices for installation and operation.
  • Disregard may lead to danger of life, burning or fire!
  • Any works on the electrical connection only by electrician.
  • Do not alter or modify the product.
  • Do not fasten anything on the product.
  • Do not cover the product.
  • Operate only with intact protection glass.
  • The supply cord may not be covered with soil.
  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or a qualified electrician to avoid hazard.
  • Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
  • Take measures that children get not harmed by the product.

Additional safety advices =

Use as directed

  • Safety class I Connection with protective conductor.
  • Operate only firmly fixed on an even surface.
  • Operate only on normal or not inflammable surfaces.
  • Do not strain mechanically or expose to strong dirt contamination.
  • IP44: Protection against foreign objects > Ø 1,0mm – Protection against splashing water from all directions.

Lamp replacement

  • Disconnect luminaire from mains and let it cool down.
  • Suitable light sources: GX53, 11W max.

Care / Storage

  • Disconnect product from mains and let it cool down.
  • Clean external surfaces regularly with a slightly moistened (water) cloth. The base may not be covered (e.g. with foliage, soil, etc.)
  • Do not clean with pressure washer.
  • Openings providing aeration or drainage must be kept free.
  • The following influences may have unwanted effects on the product: acidic surroundings, high salt content in the air, cleaning agents, fertilizer, thawing salt, chemicals.  Store dry and clean.

Installation

  • Switch off mains / fixed connection cable!
  • Use only described accessories.
  • Use only suitable fastening materials.
  • Only suited for ground surface mounting.

Follow local regulations for outdoor installations.

  • Do not seal the product yourself (e.g. with silicone).
  • Install according to declared IP type.
  • Install as shown in the figure.

Types of fixation

  • Fixation with screws (not included in delivery).
  • Concrete anchor (supplied): to be casted into concrete.
  • The external flexible cable of the luminaire may not come into directcontact with soil.
  • Place the power supply cord into a conduit.

Electrical connection

  • Protect the connection applying an IP 68 connection box or cable
  • connector (e.g. SLV 228726).
  • Suitable terminal block: min. 400V, 16A, Pole: 3
  • Live conductor Conductor L
  • Neutral conductor Conductor N
  • Protective conductor
  • Conductor (PE)
  • Check secure fixation and proper function!