Product Information
- Model : A
- Part Numbers: 1007496, 1007497, 1007498, 1007499, 1007500, 1007501
- IP Rating: IP40 (for models 1007496, 1007497, 1007498, 1007499, 1007500, 1007501), IP54 (for models 1007575, 1007576, 1007577)
- Voltage: 220V-240V ~50/60Hz
- Luminous Flux: 4100 lm (3000K), 4300 lm (4000K) for models 1007496, 1007497, 1007498, 1007499, 1007500, 1007501
- Power : 34W
- Color Rendering Index (CRI) : >80
- Dimensions:
- For models 1007496, 1007497, 1007498, 1007499, 1007500, 1007501: 59.5 x 59.5 x 2.8 cm
- For models 1007575, 1007576: 62 x 62 x 2.8 cm
- Weight:
- For models 1007496, 1007497: 1.60 kg
- For models 1007498, 1007499, 1007500: 1.70 kg
- For models 1007501: 1.80 kg
- For models 1007575, 1007576: 1.85 kg
- For model 1007577: 1.90 kg
Product Usage Instructions
Installation:
The installation of this product should only be done by an approved
electrician who has expert knowledge and is familiar with local and national
regulations.
Light Source Replacement:
- The light source of this luminaire should only be replaced by the manufacturer, an authorized service technician, or a qualified person.
Care and Storage:
- Before cleaning, disconnect the product from the mains and allow it to cool down.
- Clean the external surfaces regularly using a slightly moistened cloth with water. Do not use any abrasive materials or chemicals.
- Store the product in a dry and clean place.
Safety Advices:
- Read the manual carefully and keep it for further use.
- Failure to follow the safety advices may result in danger to life, burning, or fire.
- Any electrical works, such as the electrical connection, should only be carried out by a qualified electrician. –
- Do not alter or modify the product in any way.
- Do not fasten anything on the product. – Do not cover the product, especially not with insulating materials.
- If you suspect a defect or malfunction, take the product out of service and contact your dealer or a qualified electrician.
- Take measures to ensure that children are not harmed by the product.
- Avoid staring directly into the active light source.
Additional Safety Advices:
- Use the product as directed and described in the manual.
- Keep a sufficient distance between the product and inflammable materials.
- Ensure sufficient aeration for the product.
INSTRUCTION MANUAL PART A
MODEL NO.:
- 1007496
- 1007497
- 1007498
- 1007499
- 1007500
- 1007501
Recess-Mounted Ceiling Light
SPECIFICATION
WEIGHT AND CAPACITY
INSTRUCTIOS
Technical Details are subject to change.
Operating Manual PART B
Recess-Mounted Ceiling Light 1007496 …97 …98 …99 …500 …501 Read manual carefully and keep for further use!
Safety advices for installation and operation. Disregard may lead to danger of life, burning or fire!
- Any works on the electrical connection only by electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
- Take measures that children get not harmed by the product.
- Do not stare into the active light source.
- Additional safety advices =
Use as directed
- Safety class II (2) Safety insulated
- Connection without protective conductor.
- Operate only firmly fixed on an even surface.
- Operate only on normal or not inflammable surfaces.
- Operate only indoors.
- Do not strain mechanically or expose to strong dirt contamination.
- IP40 : Protection against foreign objects > Ø 1,0mm
- No protection against water.
- IP54 : Protection against disturbing dust deposition
- Protection against splashing water from all directions.
- Admissible ambient temperature(ta): -20°C …+40°C.
Light Source
- The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician or a comparable qualified person. 1007496 …97
- This product contains a light source of the energy efficiency class E. 1007498 …99 …500 …501
- This product contains a light source of the energy efficiency class F.
Care / Storage
- Disconnect product from mains and let it cool down.
- Clean external surfaces regularly with a slightly moistened (water) cloth.
- Store dry and clean.
Installation
- Switch off mains / fixed connection cable!
- Use only described accessories. 1007496 …98 …500
- Only for installation into grid ceilings 60 x 60 cm. 1007497 …99 …501
- Only for installation into grid ceilings 62 x 62 cm.
- Keep sufficient distance to inflammable materials.
- Ensure sufficient aeration.
: Do not cover, especially not with insulating materials.
INSTALLATION
Install as shown in the figure.
The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
Electrical connection
- Equip flexible wire ends with suitable wire ferrules!
- Direct the fixed installation cable through strain relief.
- Live conductor Terminal L
- Neutral conductor Terminal N
- Secure strain relief.
- Ensure that the fixed installation cable is securely kept by the strain relief.
0001 06.06.2023 © SLV GmbH, Daimlerstr. 21-23, 52531 Germany, Tel. +49 (0)2451 4833-0.