SLV 1007421 LED Tria Ledmodule DTW Phase Dim Black Instruction Manual
- June 13, 2024
- SLV
Table of Contents
SLV 1007421 LED Tria Ledmodule DTW Phase Dim Black
DIMENSION
FEATURES
INSTALLATION INSTRUCTION
- The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
- The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.
Operating Manual PART B
LED Module for New Tria 68 / 75 Installation ring 1007421 …22
Read manual carefully and keep for further use!
Safety advice for installation and operation. Disregarding may lead to danger of life, burning or fire!
- Any work on the electrical connection only by the electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
- Take measures that children get not harmed by the product.
- Do not stare into the active light source.
- Additional safety advice =
Use as directed
Operate only in combination with New Tria 68 / 75 installation rings. Safety
class II (2) – Safety insulated – Connection without a protective conductor.
Operate only in dry indoor areas. Do not strain mechanically or expose to
strong dirt contamination. Admissible ambient temperature(ta): -20°C …+35°C.
Light Source
The light source of this luminaire may only be replaced by the manufacturer,
an authorized service technician or a comparable qualified person. This
product contains a light source of the energy efficiency class F.
Care / Storage
Disconnect the product from the mains and let it cool down. Clean external surfaces regularly with a slightly moistened (water) cloth. Store dry and clean.
Installation
Switch off mains / fixed connection cable! Install as shown in the figure. Suitable Dimmer: Leading-edge phase dimmer (Code L) / Trailingedge phase dimmer (Code C). Note the manufacturer’s instructions.
Electrical connection
Equip flexible wire ends with suitable wire ferrules! Direct the fixed
installation cable through strain relief.
- Live conductor → Terminal L
- Neutral conductor → Terminal N
Connection lead with protective conductor: The green-yellow wire (protective conductor) of the connection lead has to be tightly connected with clamp E of the product. Secure strain relief. Ensure that the fixed installation cable is securely kept by the strain relief.
- Check secure fixation and proper function!
0001 © 28.04.2023 SLV GmbH, Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany, Tel. +49 (0)2451 4833-0. Made in China.