SLV 1007401 Recess-Mounted Ceiling Light Instruction Manual

June 13, 2024
SLV

SLV logo1 1007401 Recess-Mounted Ceiling Light
Instruction Manual

1007401 Recess-Mounted Ceiling Light

SLV 1007401 Recess-Mounted Ceiling Light

SLV 1007401 Recess-Mounted Ceiling Light - feager2

INSTRUCTION MANUAL PART A
Recess-Mounted Ceiling Light

SLV 1007401 Recess-Mounted Ceiling Light - feager

The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!

The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.
Technical Details are subject to change.

Operating Manual PART B Recess-Mounted Ceiling Light
1007401 …02 …03 …04

Read manual carefully and keep for further use!
Safety advices for installation and operation.
Disregard may lead to danger of life, burning or fire!
Any works on the electrical connection only by electrician.
Do not alter or modify the product.
Do not fasten anything on the product.
Do not cover the product.
Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
Take measures that children get not harmed by the product.
Do not stare into the active light source.
Additional safety advices =

Use as directed

Safety class II (2) ****– Safety insulated – Connection without protective conductor.
Operate only firmly fixed on an even surface.
Operate only on normal or not inflammable surfaces.
Operate only in dry indoor area.
Do not strain mechanically or expose to strong dirt contamination.
Admissible ambient temperature(ta): -20°C …35°C.

Light Source

The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician or a comparable qualified person.
This product contains a light source of the energy efficiency class F
Care / Storage
 Disconnect product from mains and let it cool down.
Clean external surfaces regularly with a slightly moistened (water) cloth.
Store dry and clean.

Installation

Switch off mains / fixed connection cable!
Use only described accessories.
Only suited for recessed ceiling installation.
Keep sufficient distance to inflammable materials.
Ensure sufficient aeration.
Install as shown in the figure.
Suitable Dimmer: Leading-edge phase dimmer (Code L) / Trailing-edge phase dimmer (Code C). Note manufacturers instructions.
Electrical connection
Equip flexible wire ends with suitable wire ferrules!
Direct the fixed installation cable through strain relief.
Live conductor Terminal L
Neutral conductor Terminal N
Connection lead with protective conductor: The green-yellow wire (protective conductor) of the connection lead has to be tightly connected with clamp E of the product.
Secure strain relief.
Ensure that the fixed installation cable is securely kept by the strain relief.
Check secure fixation and proper function!