SLV 1007396 Recess Mounted Ceiling Light
Product information
- Product Name: Recess-Mounted Ceiling Light
- Model Numbers: 1007385, 1007386, 1007387, 1007388, 1007389, 1007390, 1007391, 1007392, 1007393, 1007394, 1007395, 1007396, 1007397, 1007397 007398, 1007399, 1007400
- Power Supply: 220V-240V ~50/60Hz
- Power Consumption: 8.3W
- Luminous Flux: 705 lm (2700K), 750 lm (3000K)
- Color Temperature: 2700K (warm white), 3000K (neutral white)
- Color Rendering Index (CRI): >90
- Weight: 0.20 kg
Product Usage Instructions
- LED Drivers:
- There are two LED drivers in the product.
- Connect the primary (PRI) and secondary (SEC) terminals of each LED driver as indicated.
- LEDs:
- The light source (LED) of this luminaire can only be replaced by the manufacturer, an authorized service technician, or a qualified person.
- The product contains a light source of energy efficiency class F.
- Installation:
- Ensure that installation is carried out by an approved electrician, following local and national regulations.
- Switch off the mains/fixed connection cable before installation.
- Use only the described accessories.
- The product is suitable for recessed ceiling installation only.
- Keep a sufficient distance from inflammable materials.
- Ensure sufficient aeration for the product.
- Refer to the figure provided for installation instructions.
- Use a suitable dimmer: Leading-edge phase dimmer (Code L) or Trailing-edge phase dimmer (Code C).
- Follow the manufacturer’s instructions for the dimmer.
- Electrical Connection:
- Equip flexible wire ends with suitable wire ferrules.
- Direct the fixed installation cable through strain relief.
- Connect the live conductor (Terminal L) and the neutral conductor (Terminal N) as indicated.
- The green-yellow wire (protective conductor) of the connection lead must be tightly connected with clamp E of the product.
- Ensure strain relief for the cables.
- Securely keep the fixed installation cable using the strain relief.
Note:
Please read the manual carefully and keep it for future reference.
Disregarding the safety advice may lead to danger of life, burning, or fire.
If you suspect a defect or malfunction, contact your dealer or a qualified
electrician. Ensure that children are not harmed by the product and avoid
staring into the active light source. Disconnect the product from the mains
and let it cool down before cleaning or storing.
Specification
1007385 …86|
220V- 240V
~50/60Hz
|
8,3W
| 705 lm| 2700K|
CRI >90
| 38°|
Ø 8,2 x 4 cm
|
0,20 kg
---|---|---|---|---|---|---|---|---
1007387…88| 60°
1007389 …90| 750 lm| 3000K| 38°
1007391 …92| 60°
1007393 …94| 705 lm| 2700K| 38°|
8,2 x 8,2 x 4 cm
1007395 …96| 60°
1007397 …98| 750 lm| 3000K| 38°
1007399 …400| 60°
Features
- The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
- The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.
- Technical Details are subject to change.
Operating Manual PART B
Recess-Mounted Ceiling Light
1007385 …86 …87 …88 …89 …90 …91 …92 …93 …94 …93 …94 …95 …96 …97 …98 …99 …400.
Safety
- Read the manual carefully and keep it for further use!
- Safety advice for installation and operation.
- Disregarding may lead to danger of life, burning, or fire!
- Any work on the electrical connection only by the electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
- Take measures that children are not harmed by the product.
- Do not stare into the active light source.
- Additional safety advice.
Use as directed
- Safety class II (2) – Safety insulated – Connection without a protective conductor.
- Operate only firmly fixed on an even surface.
- Operate only on normal or not inflammable surfaces.
- Operate only in dry indoor areas.
- Do not strain mechanically or expose to strong dirt contamination.
- Admissible ambient temperature(ta): -20°C …35°C.
Light Source
- The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician, or a comparable qualified person.
- This product contains a light source of the energy efficiency class F.
Care/Storage
- Disconnect the product from the mains and let it cool down.
- Clean external surfaces regularly with a slightly moistened (water) cloth. Store dry and clean.
Installation
- Switch off mains / fixed connection cable!
- Use only described accessories.
- Only suited for recessed ceiling installation.
- Keep a sufficient distance from inflammable materials.
- Ensure sufficient aeration.
- Install as shown in the figure.
- Suitable Dimmer: Leading-edge phase dimmer (Code L) / Trailing-edge phase dimmer (Code C). Note the manufacturer’s instructions.
Electrical connection
- Equip flexible wire ends with suitable wire ferrules!
- Direct the fixed installation cable through strain relief.
- Live conductor –> Terminal L
- Neutral conductor –> Terminal N
- Connection lead with protective conductor: The green-yellow wire (protective conductor) of the connection lead has to be tightly connected with clamp E of the product.
- Secure strain relief.
- Ensure that the fixed installation cable is securely kept by the strain relief.
- Check secure fixation and proper function!