SLV 1006415 Wall and Ceiling Light Instruction Manual

June 13, 2024
SLV

SLV 1006415 Wall and Ceiling Light

INSTRUCTION MANUAL PART A Wall- and Ceiling Light

Specification

1006411

…12

|

220V-240V

~0/50/60Hz

| 10W| 1250 lm (3000K)

1250 lm (4000K)

|

CRI >90

| Ø 28 x 9,2 cm| 1,50 kg
---|---|---|---|---|---|---
1006414

…15

| 19W| 2400 lm (3000K)

2500 lm (4000K)

| Ø 38 x 9,2 cm| 2,00 kg
1006417

…18

| 37W| 5000 lm (3000K)

5100 lm (4000K)

| Ø 60 x 9,2 cm| 4,60 kg
1006420

…21

| 75W| 9400 lm (3000K)

9700 lm (4000K)

| Ø 90 x 9,2 cm| 9,00 kg

Tools

SymbolsSLV-1006415-Wall-and-Ceiling-Light-FIG-2

Installation

SLV-1006415-Wall-and-Ceiling-Light-
FIG-3SLV-1006415-Wall-and-Ceiling-Light-
FIG-4

The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!

The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.

Operating Manual PART B Wall- and Ceiling Light
1006411 …12 …14 …15 …17 …18 …20 …21

  • Read the manual carefully and keep for further use!
  • Safety advice for installation and operation.
  • Disregarding may lead to danger of life, burning or fire!
  • Any work on the electrical connection only by the electrician.
  • Do not alter or modify the product.
  • Do not fasten anything on the product.
  • Do not cover the product.
  • Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
  • Take measures that children are not harmed by the product.
  • Do not stare into the active light source.
  • Additional safety advice =

Use as directed

  • Safety class I (1) – Connection with protective conductor.
  • Operate only firmly fixed on an even surface.
  • Operate only on normal or not inflammable surfaces.
  • Operate only in dry indoor areas.
  • Do not strain mechanically or expose to strong dirt contamination.
  • IP50: Protection against disturbing dust deposition – No protection against water.
  • Admissible ambient temperature(ta): -25°C …+45°C.

Light Source

  • The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician or a comparable qualified person.
  • This product contains a light source of the energy efficiency class C.
  • Reference control setting: 4000K

Care / Storage

  • Disconnect the product from mains and let it cool down.
  • Clean external surfaces regularly with a slightly moistened (water) cloth.
  • Store dry and clean.

Installation

  • Switch off mains / fixed connection cable!
  • Use only described accessories.
  • Use only suitable fastening materials.
  • 1006411 …12 …14 …15 …17 …18
  • Only suited for wall and ceiling surface mounting.
  • 1006420 …21
  • Only suited for ceiling surface mounting.
  • Install according to the declared IP type.
  • Install as shown in the figure.
  • Suitable Dimmer: DALI dimmer / light control. Note the manufacturer`s instructions.

Electrical connection

Equip flexible wire ends with suitable wire ferrules!

  • Live conductor Terminal L
  • Neutral conductor Terminal N
  • Protective conductor Earth terminal
  • Dali control wires Terminals DA

Check secure fixation and proper function!

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals