Product Information
- Model Numbers: 1007433, 1007434, 1007435, 1007436, 1007437, 1007438, 1007439, 1007440
- Power Supply: 220V-240V ~50/60Hz
- Color Rendering Index (CRI): >90
- Weight: 0.21 kg
- Color Temperature Options: 2500K, 3000K, 4000K
- Light Output (at different current levels):
- 100mA/4.6W: 330lm (2500K), 360lm (3000K), 360lm (4000K)
- 120mA/5.5W: 370lm (2500K), 420lm (3000K), 420lm (4000K)
- 155mA/7.3W: 460lm (2500K), 510lm (3000K), 510lm (4000K)
- 180mA/8.6W: 540lm (2500K), 600lm (3000K), 600lm (4000K)
- Dimensions:
- A: 9 mm
- B: 3mm – 20mm
- AB: 68 mm
- B: 45 mm
- Installation Requirements: Expert knowledge and approval from an electrician, following local and national regulations
- Language Options: English (EN), Dutch (NL), Russian (RU), Danish (DA), Turkish (TR), German (Betriebsanleitung)
Product Usage Instructions
- Disconnect the product from the mains and allow it to cool down before handling.
- Clean the external surfaces of the product regularly using a slightly moistened cloth.
- Store the product in a dry and clean place.
- Switch off the mains/fixed connection cable before installation.
- Ensure you have the necessary accessories as described in the manual.
- This product is suitable for recessed ceiling installation only.
- Keep a sufficient distance between the product and any inflammable materials.
- Ensure proper ventilation during installation.
- Follow the installation diagram provided, ensuring that the product is not covered, especially not with insulating materials.
- Use a suitable dimmer (Leading-edge phase dimmer or Trailing-edge phase dimmer) as specified in the manufacturer’s instructions.
- For electrical connection, equip flexible wire ends with suitable wire ferrules and direct the fixed installation cable through strain relief.
- Connect the live conductor to Terminal L and the neutral conductor to Terminal N. The green-yellow wire (protective conductor) of the connection lead must be tightly connected with clamp E of the product.
- Ensure strain relief and secure the fixed installation cable properly.
- Refer to the specific language instructions in the manual for further safety and usage guidelines.
Specification
1007433 …34|
220V- 240V
~50/60Hz
|
CRI >90
| 38°| Ø 8,2 x 3,4 cm|
0,21 kg
---|---|---|---|---|---
1007437 …38| 8,2 x 8,2 x 3,4 cm
1007435 …36| 60°| Ø 8,2 x 3,4 cm
1007439 …40| 8,2 x 8,2 x 3,4 cm
| 100mA / 4,6W| 120mA / 5,5W| 155mA /
7,3W| 180mA / 8,6W
---|---|---|---|---
2500K| 330lm| 370lm| 460lm| 540lm
3000K| 360lm| 420lm| 510lm| 600lm
4000K| 360lm| 420lm| 510lm| 600lm
Features
- The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
- The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.
Operating Manual PART B Recess-Mounted Ceiling Light
1007433 …34 1007435 …36 1007437 …38 1007439 …40
Read the manual carefully and keep it for further use!
- Safety advice for installation and operation.
- Disregarding may lead to danger of life, burning, or fire!
- Any work on the electrical connection only by the electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
- Take measures that children are not harmed by the product.
- Do not stare into the active light source.
- Additional safety advice
Use as directed
- Safety class II (2) – Safety insulated – Connection without a protective conductor.
- Operate only firmly fixed on an even surface.
- Operate only on normal or not inflammable surfaces.
- Operate only in dry indoor areas.
- Do not strain mechanically or expose to strong dirt contamination.
- Admissible ambient temperature(ta): -20°C …35°C.
Light Source
- The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician or a comparable qualified person.
- This product contains a light source of the energy efficiency class F.
- Reference control setting: 4000K
Care/Storage
- Disconnect the product from the mains and let it cool down.
- Clean external surfaces regularly with a slightly moistened (water) cloth. Store dry and clean.
Installation
- Switch off mains/fixed connection cable!
- Use only described accessories.
- Only suited for recessed ceiling installation.
- Keep sufficient distance from inflammable materials.
- Ensure sufficient aeration.
- Do not cover, especially not with insulating materials.
- Install as shown in the figure.
- Suitable Dimmer: Leading-edge phase dimmer (Code L) / Trailing-edge phase dimmer (Code C). Note the manufacturer’s instructions.
Electrical connection
- Equip flexible wire ends with suitable wire ferrules!
- Direct the fixed installation cable through strain relief.
- Live conductor – > Terminal L
- Neutral conductor – > Terminal N
- Connection lead with protective conductor: The green-yellow wire (protective conductor) of the connection lead has to be tightly connected with clamp E of the product.
- Secure strain relief.
- Ensure that the fixed installation cable is securely kept by the strain relief.
- Check secure fixation and proper function!
© 0001 28.04.2023 SLV GmbH, Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany, Tel. +49 (0)2451 4833-0. Made in China.