SLV Medo pro Wall and Ceiling Light Instruction Manual
- June 13, 2024
- SLV
Table of Contents
SLV Medo pro-Wall and Ceiling Light
The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
1007284 …85|
220V-240V
~50/60Hz
| 10W| 1250 lm (3000K) / 1250 lm (4000K)|
CRI >90
| ta: -20°C
…+45°C
| Ø 28 x 9,2 cm| 1,50 kg
---|---|---|---|---|---|---|---
1007286 …87| 1350 lm (3000K) / 1350 lm (4000K)
1007292 …93| 19W| 2400 lm (3000K) / 2500 lm (4000K)| ta:
-20°C
…+30°C
| Ø 38 x 9,2 cm| 2,00 kg
1007294 …95| 2650 lm (3000K) / 2650 lm (4000K)
1007300 …01| 39W| 5000 lm (3000K) / 5100 lm (4000K)| ta:
-20°C
…+40°C
| Ø 60 x 9,2 cm| 4,60 kg
1007302 …03| 5450 lm (3000K) / 5500 lm (4000K)
1007308 …09| 75W| 9400 lm (3000K) / 9700 lm (4000K)| ta:
-20°C
…+40°C
| Ø 90 x 9,2 cm| 9,00 kg
1007310 …11| 11000 lm (3000K) / 11200 lm (4000K)
![1007284 ...85
220V-240V
~50/60Hz 10W 1250 lm (3000K) / 1250 lm (4000K)
CRI>90 ta: -20°C
...+45°C Ø 28 x 9,2 cm 1,50 kg
1007286 ...87 1350 lm (3000K) / 1350 lm (4000K)
1007292 ...93 19W 2400 lm (3000K) / 2500 lm (4000K) ta: -20°C
...+30°C Ø 38 x 9,2 cm 2,00 kg
1007294 ...95 2650 lm (3000K) / 2650 lm (4000K)
1007300 ...01 39W 5000 lm (3000K) / 5100 lm (4000K) ta: -20°C
...+40°C Ø 60 x 9,2 cm 4,60 kg
1007302 ...03 5450 lm (3000K) / 5500 lm (4000K)
1007308 ...09 75W 9400 lm (3000K) / 9700 lm (4000K) ta: -20°C
...+40°C Ø 90 x 9,2 cm 9,00 kg
SLV-Medo-pro-Wall-and-Ceiling-Light-FIG-2](https://manuals.plus/wp- content/uploads/2023/10/SLV-Medo-pro-Wall-and-Ceiling-Light-FIG-2.jpg)
The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.
Operating Manual PART B
Wall- and Ceiling Light
- 1007284 …85 …86 …87 1007292 …93 …94 …95
- 1007300 …01 …02 …03 1007308 …09 …10 …11
- Read the manual carefully and keep it for further use!
- Safety advice for installation and operation.
- Disregarding may lead to danger of life, burning, or fire!
- Any work on the electrical connection only by the electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
- Take measures that children are not harmed by the product.
- Do not stare into the active light source.
Additional safety advice
Use as directed
- Safety class I (1) – Connection with protective conductor.
- Operate only firmly fixed on an even surface.
- Operate only on normal or not inflammable surfaces.
- Operate only in dry indoor areas.
- Do not strain mechanically or expose to strong dirt contamination.
- IP50: Protection against disturbing dust deposition – No protection against water.
- 1007284 …85 …86 …87:
- Admissible ambient temperature (ta): -20°C …+45°C
- 1007292 …93 …94 …95:
- Admissible ambient temperature (ta): -20°C …+30°C
- 1007300 …01 …02 …03:
- Admissible ambient temperature (ta): -20°C …+40°C
- 1007308 …09 …10 …11:
- Admissible ambient temperature(ta): -20°C …+40°C
Light Source
The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician, or a comparable qualified person. This product contains a light source of the energy efficiency class C. Reference control setting: 4000K
Care / Storage
- Disconnect the product from the mains and let it cool down.
- Clean external surfaces regularly with a slightly moistened (water) cloth.
- Store dry and clean.
Installation
- Switch off mains / fixed connection cable!
- Use only described accessories.
- Use only suitable fastening materials.
- 1007284 …85 …86 …87 1007292 …93 …94 …95 1007300 …01 …02 …03
- Only suited for wall and ceiling surface mounting.
- 1007308 …09 …10 …11
- Only suited for ceiling surface mounting.
- Install according to the declared IP type.
- Install as shown in the figure.
- Suitable Dimmer: DALI dimmer / light control. Note the manufacturer`s instructions.
Electrical connection
- Equip flexible wire ends with suitable wire ferrules!
- Live conductor
- Terminal L
- Neutral conductor
- Terminal N
- Protective conductor
- Earth terminal
- Dali control wires
- Terminals DA
- Check secure fixation and proper function!
© 0001 12.04.2023 SLV GmbH, Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany, Tel. +49 (0)2451 4833-0. Made in China