SLV 1006561 48V Mounting Track Recessed Instruction Manual
- June 12, 2024
- SLV
Table of Contents
SLV 1006561 48V Mounting Track Recessed
Read manual carefully and keep for further use!
Safety advices for installation and operation. Disregard may lead to danger of life, burning or fire!
The components and luminaires of this system may not be combined with track systems of safety class I or II or with any other track system.
The track ends must be covered with end caps suitable for the system.
Do not fasten anything on the product.
Do not cover the product.
Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
Take measures that children get not harmed by the product.
Additional safety advices = ****
Use as directed
Electrical Track System for lighting
Safety class III (3) – Operated with safety extra-low voltage.
Operate only in dry indoor area.
Do not strain mechanically or expose to strong dirt contamination.
Parts Lists
The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
Dimension
Operation
**** It is the responsibility of the user to ensure the electrical and
thermal compatibility between the rail system and the luminaires connected to
it.
Caution: To avoid the danger of overheating and fire the conductors may not be
bridged.
The electrical screw connections have to be checked regularly on the voltage-
free track and if necessary be tightened hand-screwed.
Do not direct luminaires on the track, other luminaires or the transformer.
Care / Storage
**** Disconnect product from mains and let it cool down.
Clean external surfaces regularly with a slightly moistened (water) cloth.
Store dry and clean.
Installation
**** Switch off mains / fixed connection cable!
Use only described accessories.
The system is suited to be installed into a cavity ceiling (A) and solid
ceilings and walls (B).
Note the load limit.
The specified admissible mechanical load of the tracks is the total load of a
complete system.
Install as shown in the figure.
When mounting in a cavity ceiling, the system must be fastened to a solid
background with the suspensions belonging to the system.
Ceiling elements positioned at the track may not strain the track and must be
suspended individually.
Prepare power supply.
The feed-in may only be connected to a SELV supply which is specified to
operate components of the safety class III.
The electrical connection with screws on feed-ins have to be tightened
securely.
All open rail ends must be equipped with end caps.
**** Check secure fixation and proper function!
Customer Support
© 26.10.2022 SLV GmbH,
Daimlerstr. 21-23, 52531 Übach-Palenberg,
Germany,
Tel. +49 (0)2451 4833-0.
Made in China.