SLV 1006452 Trailing Edge Dimmer Instruction Manual
- June 12, 2024
- SLV
Table of Contents
INSTRUCTION MANUAL PART A
Trailing Edge Dimmer with DALI Control Input and
Push-Function for LED Lighting
1006452
1006452 Trailing Edge Dimmer
Uin 100-240V AC | Uout 100-240V AC | Iout 1,8A max. |
---|---|---|
DALI (in) 2mA max. | 4,5 x 4,5 x 2 cm |
The installation requires expert knowledge and may be carried out only by an
approved electrician under consideration of local and national regulations!
SLV UK Unit E Chiltern Park I Boscombe Road, Bedfordshire LU5 4LT
Operating Manual PART B
Trailing Edge Dimmer with DALI Control Input and Push-Function for LED
Lighting 1006452
Read manual carefully and keep for further use!
Safety advices for installation and operation.
Disregard may lead to danger of life, burning or fire!
Any works on the electrical connection only by electrician.
Do not alter or modify the product.
Do not open the housing, it protects against touching active parts.
The load of the connected LED lighting may not exceed the maximum load of the
device.
Take out of service when suspecting a defect or malfunction and contact your
dealer or a qualified electrician.
Additional safety advices =
Furnishing
Built-in DALI 2 Interface, DALI DT6 Device
Use as directed
This product is suited to control the brightness of LED lighting with an
input power of 100 – 240V AC.
Safety class II (2) – Safety insulated – Connection
without protective conductor.
Do not strain mechanically or expose to strong dirt contamination.
Admissible ambient temperature(ta): -20°C …+50°C.
Admissible load types
Symbol | Load Type | Max. Load |
---|---|---|
Dimmable | ||
LED Lamp | 230V: 200W |
120V: 100W
| Dimmable
LED Driver| 230V: 200W
120V: 100W
Installation
Switch off mains / fixed connection cable!
The device is suitable for installation in a standard flush-mounted box (Ø:
60mm / min. depth 45 mm).
Access to the built-in product must only be possible via a tool.
Electrical connection
See connection diagrams.
Connection to DALI Fig. A
Connection to a Push-button Fig. B
Equip flexible wire ends with suitable wire ferrules!
Live conductor → Terminal L
Neutral conductor → Terminal N
Operation
DALI
Please read the instruction of the DALI master device to setup the DALI
address.
Push-button Operation
A short push switches the light on and off.
A short push changes the brightness.
Settings
Setting and deleting the minimum brightness
Adjust the desired minimum brightness via DALI or push-function.
Push the button “Min. Set” on the device until the LED on the device starts to
flash.
To delete the minimum brightness, adjust the brightness to the highest level
and push the button “Min. Set”. The flashing LED on the device indicates that
the minimum brightness was deleted.
Notice: The dimming range ranges from 1 – 100%. With some load types it may
appear that the connected light flashes at a dimming level of 1%. In such
cases it is recommended to set the minimum brightness above 1%.
© 22.11.2022 SLV GmbH, Daimlerstr. 21-23, 52531
Übach-Palenberg, Germany,
Tel. +49 (0)2451 4833-0.
Made in China.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>