SLV 1007095 Recess-Mounted Ceiling Light Instruction Manual
- June 13, 2024
- SLV
Table of Contents
SLV 1007095 Recess-Mounted Ceiling Light
Product information
The product is a recess-mounted ceiling light with the model number 1007095. It has two different IP ratings, IP20 and IP65, indicating its level of protection against dust and water. The light has a brightness of 410 lm in the 2700K color temperature and can be adjusted to 560 lm. It operates on a voltage range of 220V-240V at a frequency of 50/60Hz. The power consumption is either 5W or 8W, depending on the model. It has a weight of 0.27 kg and a CRI (Color Rendering Index) of over 90.
Installation Requirements
- The installation should only be carried out by an approved electrician who has expert knowledge.
- The installation must comply with local and national regulations.
Usage Instructions
- Do not attempt to replace the light source or the control gear as they are not replaceable.
- Read the operating manual carefully and keep it for future reference.
- Follow the safety advice for installation and operation to avoid any danger to life, burning, or fire.
- Any electrical connection works should only be done by an electrician.
- Do not alter or modify the product in any way.
- Do not attach anything onto the product.
- Do not cover the product.
- If there is a suspicion of defect or malfunction, take the product out of service and contact the dealer or a qualified electrician.
- Keep the product away from children to prevent harm.
- Avoid staring directly into the active light source.
Additional Safety Advice
- Use the product as directed.
- The light source of the luminaire is not replaceable. If it needs to be replaced, the entire luminaire must be replaced.
- Disconnect the product from the mains and let it cool down before cleaning or storing.
- Regularly clean the external surfaces with a slightly moistened cloth.
- Store the product in a dry and clean place.
Specifications
220V-240V ~50/60Hz
|
5W / 8W
| 410 lm / 560 lm| 2700K|
CRI >90
|
Ø 8,5 x 4,9 cm
|
0,27 kg
---|---|---|---|---|---|---
430 lm / 610 lm| 3000K
470 lm / 680 lm| 4000K
440 lm / 640 lm| 6500K
Features
Installation Instructions
- The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
- The light source is not replaceable. The control gear is not replaceable.
Technical Details are subject to change.
Disposal (European Union)
Do not dispose of the product with regular household waste! Products marked with this sign must be disposed of according to the directive (WEEE) on electrical and electronic devices at local collection points for such devices!
Waste batteries and accumulators, which are not enclosed by the waste equipment, and lamps, which are removable non-destructively from the waste equipment are to be separated non-destructively from the waste equipment before turning to a local collection point. Distributors are, according to particular legislation, obligated to take back waste equipment from the final holder. It lies in the personal responsibility of the final holder to delete personal data before the disposal. For disposal the waste equipment may be sent to the following address:
- SLV GmbH
- Technischer Service
- Werkstrasse 8-10
- 52531 Übach-Palenberg, Germany
Operating
- Read manual carefully and keep for further use!
- Safety advices for installation and operation.
- Disregard may lead to danger of life, burning or fire!
- Any works on the electrical connection only by electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
- Take measures that children get not harmed by the product.
- Do not stare into the active light source.
- Additional safety advices =
Use as directed
- Safety class II (2) – Safety insulated – Connection without protective conductor.
- Operate only firmly fixed on an even surface.
- Operate only on normal or not inflammable surfaces.
- Operate only in dry indoor area.
- IP20: Protection against foreign objects > Ø 12,5mm – No protection against water.
- IP65: Protection against dust (dust-tight) – Protection against jetted water from all directions.
- Do not strain mechanically or expose to strong dirt contamination.
- Admissible ambient temperature(ta): -20°C …+40°C.
Light Source
- The light source of this luminaire is not replaceable. In case the light source must be replaced (e.g. at the end of its lifetime) the whole luminaire needs to be replaced.
- This product contains a light source of the energy efficiency class F.
- Reference control setting: 6500K
Care / Storage
- Disconnect the product from the mains and let it cool down.
- Clean external surfaces regularly with a slightly moistened (water) cloth.
- Store dry and clean.
Installation
- Switch off mains / fixed connection cable!
- Use only described accessories.
- Only suited for recessed ceiling installation.
- Keep sufficient distance to inflammable materials.
- Ensure sufficient aeration.
- Install as shown in the figure.
- Suitable Dimmer: Trailing-edge phase dimmer (Code C). Note the manufacturer’s instructions.
Electrical connection
- Equip flexible wire ends with suitable wire ferrules!
- Direct the fixed installation cable through the strain relief.
- Live conductor: Terminal L
- Neutral conductor: Terminal N
- Connection lead with protective conductor: The green-yellow wire (protective conductor) of the connection lead has to be tightly connected with clamp E of the product.
- Secure strain relief.
- Ensure that the fixed installation cable is securely kept by the strain relief.
Check secure fixation and proper function!
SLV GmbH
- Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany
- Tel: +49 (0)2451 4833-0.
Made in China.