BEGA 50 568.1 Ceiling Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
BEGA 50 568.1 Ceiling Luminaire
Product Information
The product is a luminaire that requires installation and operation in accordance with national safety regulations. It is recommended to have a qualified electrician perform the installation and commissioning to avoid any damage caused by improper use or installation. The manufacturer does not acceptliability for such damages. The luminaire is equipped with electronic components that are protected against overvoltage, and additional overvoltage protection components are recommended for enhanced protection. More information on these components can be found on the manufacturer’s website at www.bega.com.
The luminaire is available in two models: 50 568.1 K27 and 50 568.1 K3. Both models have different specifications for module designation, color temperature, color rendering index, module luminous flux, luminaire luminous flux, and luminaire luminous efficiency. The connected wattage for the lamp module is 11.5 W and for the luminaire is 13.5 W. The rated temperature is 25°C and the ambient temperature should also be maintained at 25°C. LED modules are used in the luminaire, which are high-quality electronic components. During installation or relamping, it is important to avoid touching the light output opening of the LED directly.
To ensure a secure connection, precise positioning of the luminaire housing in relation to the mounting plate is crucial. The vertical bar inside the housing should align with the mounting hole on the long bar of the mounting plate. Firmly press the housing against the plate and turn it clockwise until it stops. If replacement of the LED module is required, the designation of the module can be found on a label inside the luminaire. The replacement modules provided by BEGA have matching light color and output. Qualified individuals can replace the module using standard tools. Before replacing the module, disconnect the system and open the luminaire following the installation instructions for the LED module. If the glass is defective, it should be replaced before closing the luminaire.
Product Usage Instructions
- Ensure that the installation and operation of the luminaire comply with national safety regulations.
- If you are not a qualified electrician, hire one to perform the installation and commissioning.
- For enhanced protection against overvoltage, consider using separate overvoltage protection components available on the manufacturer’s website.
- Avoid touching the light output opening of the LED directly during installation or relamping.
- Precisely position the luminaire housing in relation to the mounting plate by aligning the vertical bar inside the housing with the mounting hole on the long bar of the mounting plate.
- Firmly press the housing against the mounting plate and turn it clockwise until it stops.
- To open the luminaire, unscrew the glass from the housing by turning it counter-clockwise. Hold the housing in place to prevent it from turning on the mounting plate.
- If a replacement LED module is needed, locate the designation of the module on a label inside the luminaire.
- Disconnect the system and open the luminaire to replace the module following the installation instructions provided for the LED module.
- If the glass is defective, replace it before closing the luminaire.
Dimensions
Instructions for use
Application
- Ceiling luminaire · Indoor luminaire with wide beam light distribution.
Product Description
- Aluminium alloy housing, finish Colour velvet white
- Crystal glass, partially satin matt, with screw neck
- Reflector made of pure anodised aluminium 2 mounting holes ø 4.5 mm
- Distance apart: 112 mm
- The luminaire is suitable for through-wiring.
- Connecting terminals: 2.5@
- Earth conductor connection
- LED power supply unit: 220-240 V x 0/50-60 Hz
- DC 176-280 V
- DALI-controllable
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Switch®
- Temporary thermal shutdown to protecttemperature-sensitive components
- Safety class: I
- Impact strength: IK06
- Protection against mechanical impacts < 1 joule
- : Safety mark
- CE: Conformity mark
- Weight: 1.2 kg
- This product contains light sources of energy efficiency classes E
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible forthese modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage inaccordance with DIN EN 61547. To achieve an additional
protection against e. g. transients, etc. we recommend separate overvoltage
protection components. You can find them on our website at
www.bega.com.
Lamp
- Module connected wattage 11.5 W
- Luminaire connected wattage 13.5 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 25 °C
- 50 568.1 K27
- Module designation LED-0800/927
- Colour temperature 2700 K
- Colour rendering index CRI > 90
- Module luminous flux 1665 lm
- Luminaire luminous flux 1333 lm
- Luminaire luminous efficiency 98,7 lm / W
- 50 568.1 K3
- Module designation LED-0800/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 1735 lm
- Luminaire luminous flux 1389 lm
- Luminaire luminous efficiency 102,9 lm / W
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping Remove mounting plate from the luminaire housing. Unplug the earth conductor connection (plug contact).
Please note:
If the luminaire is to be mounted onto a metallic, electroconductive surface,
it is mandatory to make sure that the mounting surface is connected
conductively to the earth conductor of the luminaire! Lead the power
connecting cable through the mounting plate. Fix the mounting plate with
enclosed or any other suitable fixing material onto the mounting surface.
Establish the earth conductor connection to the luminaire housing (plug
contact). Make earth conductor connection. Push silicone sleeves over the
lines and make electrical connection. The two connecting terminals marked DA,
DA are provided for digital control purposes. If these terminals are not
assigned, the luminaire will work with full light output.
IMPORTANT
To ensure secure connection, the luminaire housing must be positioned precisely in relation to the mounting plate. Make sure that the vertical bar inside the luminaire housing is positioned precisely in the area of the mounting hole on the long bar of the mounting plate. Press the luminaire housing firmly against the mounting plate and turn it clockwise firmly against the stop.
Open luminaire:
Unscrew glass from the luminaire housing by turning it counterclockwise. To
prevent the luminaire from turning on the mounting plate, hold the luminaire
housing in place with one hand.
Maintenance
Cleaning · Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire. The
light colour and light output of BEGA replacement modules correspond to those
of the modules originally fitted.The module can be replaced by qualified
persons using standard tools. Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module. Defective
glass must be replaced. Close the luminaire.
BEGA Gantenbrink-Leuchten KG
- Postfach 31 60 · 58689 Menden
- info@bega.com