BEGA 50119.2K27 Recessed Wall Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 50119.2K27 Recessed Wall Luminaire

Product Information

  • This product is a luminaire that requires installation and operation according to national safety regulations. It should only be installed and commissioned by a qualified electrician. The manufacturer does not accept liability for damage caused by improper use or installation. Any modifications made to the luminaire should be done by a responsible person who will be considered the manufacturer. The luminaire is protected against overvoltage according to DIN EN 61547, but additional overvoltage protection components are recommended for extra protection. More information about these components can be found on the manufacturer’s website at www.bega.com.
  • The product comes with different module designations, color temperatures, color rendering indexes, module luminous flux, luminaire luminous flux, and luminaire luminous efficiency. These specifications are listed in the user manual.
  • Note: The luminaire is supplied with a matching cavity-wall box, but if other cavity-wall boxes are used, they must be made of electrically insulating material such as plastic.
  • Through-wiring of the luminaire is only possible with an electronic box. The recommended flush-mounted box for flush-mounting is Kaiser 1068-02, and the recommended cavity-wall box for cavity-wall mounting is Kaiser 9268-94.
  • The LED module in the luminaire can be replaced by qualified persons using standard tools. The designation of the LED module can be found on a label inside the luminaire. Replacement modules from BEGA have the same light color and light output as the originally fitted modules. When replacing the LED module, disconnect the system, open the luminaire, follow the installation instructions for the LED module, and replace any defective glass before closing the luminaire.

Product Usage Instructions

  1. Ensure that the luminaire is installed and commissioned by a qualified electrician according to national safety regulations.
  2. If additional overvoltage protection is desired, visit the manufacturer’s website at www.bega.com to find suitable components.
  3. Choose the desired module designation, color temperature, color rendering index, module luminous flux, luminaire luminous flux, and luminaire luminous efficiency based on the user manual.
  4. Use the supplied cavity-wall box for installation, or if using a different cavity-wall box, ensure it is made of electrical insulating material.
  5. If through-wiring is required, use an electronic box such as Kaiser 1068-02 for flush mounting or Kaiser 9268-94 for cavity wall mounting.
  6. When replacing the LED module, disconnect the system, open the luminaire, and refer to the installation instructions for the LED module.
  7. Replace any defective glass before closing the luminaire.

Dimension

Instructions for use

Application
Recessed wall luminaire · indoor luminaire with crystal glass, inside white and metal housing. Luminaire with unshielded light for directing and conducting lighting.

Product Description

  • Recessed ceiling luminaire »ACCENT«
  • Die-cast zinc luminaire housing
  • Metal cover frame with safety glass, white inside
  • Stainless steel finish
  • Cavity-wall box with 2 fixing claws and fixing screws
  • Ceiling aperture ø 68 mm
  • Free space installation depth required 65 mm
  • Mains cable up to ø 10.5 mm, max. 3 × 1.5@
  • Connecting terminal 1.5@
  • Earth conductor connection
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • Safety class I
  • r – Safety mark
  • c – Conformity mark
  • Weight: 0.25 kg
  • This product contains light sources of energy efficiency classes D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 1 W
  • Luminaire connected wattage 2.1 W
  • Rated temperature ta= 25 °C
  • Ambient temperature ta max= 45 °C
  • When installed in heat-insulating
  • material ta max =35 °C

50 119.2K27

  • Module designation LED -0815/927
  • Color temperature 2700 K
  • Color rendering index CR I >90
  • Module luminous flux 155 lm
  • Luminaire luminous flux 47 lm
  • Luminaire luminous efficiency 22,4 lm/W

50 119.2K3

  • Module designation LED- 0815/930
  • Colour temperature 3000 K
  • Colour rendering index CRI >90
  • Module luminous flux 160 lm
  • Luminaire luminous flux 49 lm
  • Luminaire luminous efficiency 23,3 lm/W

Installation

  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Installation into solid walls For this purpose a recess box, ø 68 mm and a recessed depth of min. 62 mm is necessary.
  • Installation into wall panels
  • A recessed opening of ø 68 mm is necessary to accept the cavity-wall box.
  • Recessed depth min. 65 mm.
  • The lateral distance between the cavity-wall box and standard combustible building parts must be at least 40 mm.
  • The claws of the cavity-wall box catch the wall panel from the backside. If the minimum thickness is less than 7 mm, it must be reinforced from the back side.
  • The maximum thickness of the panel must be no more than 35 mm.
  • Pass the mains cable through a cable entry of the cavity-wall box and fit the cavity-wall box.
  • Make sure that the countersunk screws of the cavity-wall box are horizontal relative to the ground.
  • Connect the earth conductor to the link on the luminaire housing.
  • Make an electrical connection to the terminal of the power supply unit.
  • Insert the luminaire into the cavity-wall box and use the two countersunk screws to adjust and secure it.
  • Use retention pins to mount the cover frame with glass on the luminaire housing such that the two rear magnets are seated on the countersunk screws.

Note:

  • This luminaire is supplied with a matching cavity-wall box.
  • If cavity-wall boxes of other manufacturers are used, they must be made of electrically insulating material such as plastic!

Through-wiring

  • Please note: Through wiring of the luminaire is only possible by means of an electronic box.
  • We recommend the use of a flush-mounted box Kaiser 1068-02 for flush mounting and a cavity-wall box Kaiser 9268-94 for cavity wall mounting.

Cleaning · Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt.
  • The defective glass must be replaced.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • The defective glass must be replaced.
  • Close the luminaire.

Spares

  • Glass/Trim frame 20 000 030M1
  • LED power supply unit DEV-0231/350
  • LED module 2700 K LED -0815/927
  • LED module 3000 K LED -0815/930
  • BEGA Gantenbrink-Leuchten KG
  • Postfach 3160
  • 58689 Menden
  • info@bega.com
  • www.bega.com

Documents / Resources

| BEGA 50119.2K27 Recessed Wall Luminaire [pdf] Instruction Manual
50119.2K27 Recessed Wall Luminaire, 50119.2K27, Recessed Wall Luminaire, Wall Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals