BEGA 50710.1 Recessed Ceiling Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 50710.1 Recessed Ceiling Luminaire Instruction Manual
BEGA 50710.1 Recessed Ceiling Luminaire

DIMENSIONS

Dimensions

Application

Recessed ceiling luminaire · indoor luminaire partially satin matt crystal glass inside and aluminium alloy housing. For installation into ceilings with a shallow depth in interior areas

Product description

Recessed ceiling luminaire »ACCENTA«
Die-cast aluminium housing
Crystal glass, partially satin matt inside
Reflector made of pure, high-gloss anodizedaluminium
Metal ceiling frame ring, Colour white
Recessed opening ø 68mm
Required installation depth 60mm
Fixing is achieved by using 2 adjustable
wedge-shaped claws
External LED power supply unit
220-240 V x 0/50-60 Hz
Safety class II r 2

Safety mark
Conformity mark
Weight: 0.22 kg

This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability fordamage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection againste.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp
Module connected wattage: 8.5 W
Luminaire connected wattage: 10.4 W
Rated temperature: ta=25 °C
Ambient temperature:   ta max=35 °C

Installation

Luminaire housing must not be installed in heat-insulating material.

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

The recessed opening will be covered by the frame of the luminaire. Fixing of the luminaire is achieved by using 2 adjustable wedge-shaped claws.

Installation into false ceilings

A recessed opening of ø 68 mm is necessary to accept the luminaire housing. Free space depth min. 60 mm (see sketch).
The claws catch the panel from the reverse side. If minimum thickness of the panel is less than 3 mm it must be reinforced from the reverse side. Maximum thickness of the panel must be no more than 20 mm.

Remove cover of the external LED-power supply unit.

Loosen set screws of cable strain relief. Tightening zone for strain relief: max. Ø 12mm. Connecting terminals for mains supply: max. 2,5@. Strip the wires 6 mm.

Lead mains supply cable through the cable strain relief and fix set screws. Make electrical connectio

Close case cover of the external LED-power supply unit and press it until it is locked. Push external LED-power supply unit and luminaire housing into ceiling cut-out. Luminaire housing and external LEDpower supply unit must not be installed in heat-insulating material.

Hand-tight screws of claw fasteners evenly. Lead enclosed ceiling frame ring over thescrew-neck of the glass and push it down the gasket.

Make sure that gasket is positioned correctly. Insert glass with mounted reflector and frame ring by turning it clockwise into luminaire housing.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt. Defective glass must be replaced.

Replacement of the LED module

The designation of the LED module is noted on a label in the luminaire.

The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.

Disconnect from main supply. Unscrew glass with ceiling frame ring from luminaire housing by turning it counterclockwise. Please follow the installation instructions for the LED module.

Check gasket. Screw in glass with ceiling frame ring by turning it clockwise beyond the stop. Defective glass must be replaced.

Spares

Spare glass 11 003 006 410RG
LED power supply unit DEV-0279/250
LED module 2700 K LED-0923/927
LED module 3000 K LED-0923/930
Trim ring 72 009 561 L
Reflector 76 001 209