BEGA 84 271 In-Ground Luminaire Instruction Manual

June 12, 2024
BEGA

50.21 • Technical amendments reserved

84 271

In-ground luminaire

BEGA 84 271 In-Ground Luminaire a1

Instructions for use

Application
In-ground luminaire with four-sided light sectors. For recessed mounting in compacted surfaces, paths and places.
An orientation and indication luminaire also for marking peril points.
Drive-over luminaire for vehicles with pneumatic tyres.
Please note:
Luminaire must not be used for installation in road lanes, where the fixture is exposed to a horizontal strain due to braking, acceleration and change of direction.

Product description
Luminaires and installation housings made of highly corrosion-resistant aluminium
BEGA Tricoat® coating technology
Ring made of glass fibre reinforced synthetic material
Borosilicate glass
Reflector surface made of pure aluminium
Optical silicone lens · BEGA Hybrid Optics®
Recess housing with cable entries for cable conduit, max ø 20 mm
1,8m water-resistant connecting cable
07RN8-F 5G1 with implemented water stopper and 1.2m PVC cable conduit
BEGA Ultimate Driver®
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI controllable
A basic isolation exists between power cable and control line
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 67
Dust-tight and protection against temporary immersion
Pressure load 4,000 kg (~40 kN)
Impact strength IK10
Protection against mechanical impacts < 20 joule
Maximum surface temperature 30 °C
(measured according to EN 60598 of ta 15 °C)
– Conformity mark
– Safety mark
Weight: 5.9 kg
This product contains light sources of energy efficiency class(es) D, E

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. We recommend fuse protection via a residual current circuit breaker to be provided by the customer.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp
Module connected wattage                                 18.9 W
Luminaire connected wattage                                22 W
Rated temperature                                            ta=25 °C
Ambient temperature                                 ta max=50 °C
When installed in heat-insulating material  ta max=35 °C

84 271K27
Module designation                                    LED-0959/827
Colour temperature                                                 2700 K
Colour rendering index                                          CRI >80
Module luminous flux                                             2700 lm
Luminaire luminous flux                                           504 lm
Luminaire luminous efficiency                            22,9 lm/W

84 271K3
Module designation                                      LED-0959/830
Colour temperature                                                    3000 K
Colour rendering index                                            CRI >80
Module luminous flux                                                2880 lm
Luminaire luminous flux                                              538 lm
Luminaire luminous efficiency                               24,5 lm/W

84 271K4
Module designation                                          LED-0959/840
Colour temperature                                                       4000 K
Colour rendering index                                               CRI >80
Module luminous flux                                                  3100 lm
Luminaire luminous flux                                                579 lm
Luminaire luminous efficiency                                 26,3 lm/W

Light technique
The optical system of the luminaire directs the light in a concentrated way horizontally to the lamp axis.
This results in a glare free illumination of the surface from lowest height.
The light emittance angle is 4 x 60°.

BEGA 84 271 In-Ground Luminaire a3

Notice prior to installation:
A foundation must be provided to accommodate the luminaire’s max. pressure load of 4,000 kg (~40 kN).
The luminaire stands in a highly robust cast aluminium recessed housing.
The pressure load is transferred to the foundation provided by the customer through this housing. The foundation must be laid on firm substrate.
The installation housing must be set in concrete for stability. Drainage must be provided in the foundation to allow surface water to drain from the recessed housing.
The external coating of the recessed housing must not be damaged. It is important to ensure that the floor covering installed later will be at a level with or below the upper edge of the recessed housing to guarantee a proper seal of the luminaire – see sketch (detail A ).

Soil Conditions
The luminaire must not permanently have contact with aggressive media. Aggressive media might be washed out of the soil and might corrode the housing of the luminaire. In case of an unknown composition of the soil a soil analysis should be made before installation. Aggressive media that is outgoing from the ground surface might also affect the luminaire. Thus an overuse of de-icing agents in the surroundings should be avoided. Parasitic current, occuring from the outside, can cause corrosion damage at the luminaire. Suitable counter measures must be carried out.

Installation
Dismantling the luminaire from the recess housing. For this purpose undo hexagon socket head screws (wrench size 5) in the luminaire cover. Turn luminaire counterclockwise up to the stop and lift it out of the recess housing.
Position recess housing on the foundation (as described before) and fix it with enclosed or any other suitable fixing material.

A customer-provided connecting sleeve outside of the installation housing is required to connect the luminaire to the power supply.
We recommend to use a BEGA distribution box 70 730.
Pass the protective cable conduit from the connecting sleeve into the installation housing.
Pass the connection cable through the protective conduit and connect it securely to the underground cable.
If a connection underneath the luminaire is planned, the customer must ensure that there is enough clearance. We recommend a DN 150 pipe and the 70730 distribution box for drainage. After installation, the distribution box must be sealed.

0.5 m of cable is provided in the installation housing so that the luminaire may be removed.
Note correct configuration of the mains supply cable. Make mains supply connection at the brown (L), blue (N) and green-yellow lead ( ).
The connection of the control cables is achieved by means of the both leads marked with DALI.
In case these leads are not used the luminaire will be operated at full light output.
Place lamp enclosure into recessed housing and align. Tighten locking screws firmly.

Replacing the LED module · Maintenance
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
We recommend replacing the built-in seals and desiccant bag if the luminaire has to be opened for maintenance purposes.
Article numbers are listed in the Replacements section.

BEGA 84 271 In-Ground Luminaire a5

Disconnect the electrical installation.
Free the key openings in the bolt heads from any dirt and other residue.
The use of pressure washers is not recommended.
Use only solvent-free cleaning agents on the luminaire.
Remove the luminaire from the installation housing. Undo the hexagon socket screws (wrench size 5) in the luminaire cover. Twist the luminaire counter- clockwise to the stop, pull up the screws and lift the luminaire from the installation housing.
The flexible, water-resistant connecting cable with water stop must be checked for external damage and must only be replaced with a BEGA connection cable with water stop.
Check gaskets and replace as needed.
Loosen the hexagon nuts (wrench size 10) and lift off the luminaire housing.
First push down the ring made of synthetic material firmly to remove the glass and gasket. Remove the glass and the gaskets.
Replace LED module. Follow the installation instructions for the LED module.
Insert the gasket and glass into the luminaire housing as shown in the drawing.
Pull the ring made of synthetic material up to the stop. Place the luminaire cover onto the glass and ring made of synthetic material. Make sure that the two bore holes in the ring made of synthetic material and the luminaire cover are correctly aligned.
Place the nuts onto the threaded bolts and tighten them evenly diagonally to the stop.
Torque = 6.5Nm.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Corrosive chemicals must not come in contact with the luminaire.

Accessories


70 730 Distribution box with 7 cable entries Connection terminals 5 x 4

A separate instructions for use can be provided upon request.

Spares


Spare glass                                  11 003 520
LED power supply unit       DEV-0340/700
LED module 2700 K           LED-0959/827
LED module 3000 K           LED-0959/830
LED module 4000 K           LED-0959/840
Reflector                                     76 001 879
Gasket glass                                 83 001 904
Desiccant pouch                          84 000 438

BEGA Gantenbrink-Leuchten KG • Postfach 3160 • 58689 Menden • info@bega.comwww.bega.com