Product Information

– Product Model: 51 050.1 – Power Supply: 11-230V AC – Power Consumption: 5-360W – Instructions for use available in multiple languages (German, English, French) – Safety regulations must be followed during installation and operation – Installation and commissioning should be done by a qualified electrician – Manufacturer does not accept liability for damage caused by improper use or installation – Overvoltage protection is recommended for additional protection against transients – Lamp Module connected wattage: 26.4W – Luminaire connected wattage: 29.4W – Rated temperature: ta = 25°C – Ambient temperature: ta max = 50°C – Colour temperature: 3000K – Colour rendering index (CRI): >90 – Module luminous flux: 3970 lm – Luminaire luminous flux: 2803 lm – Luminaire luminous efficiency:95.3 lm/W

Product Usage Instructions

1. Ensure that the installation and operation of the luminaire comply with national safety regulations. 2. Only a qualified electrician should carry out the installation and commissioning of the luminaire. 3. The manufacturer is not liable for any damage caused by improperuse or installation. 4. For additional protection against transients, it is recommended to use separate overvoltage protection components. These can be found on the manufacturer’s website at www.bega.com. 5. The lamp module connected wattage is 26.4W, and the luminaire connected wattage is 29.4W. 6. The rated temperature for the luminaire is ta = 25°C, and the maximum ambienttemperature should not exceed ta max = 50°C. 7. The colour temperature of the luminaire is 3000K, providing warm white light. 8. The colour rendering index (CRI) is greater than 90, ensuring accurate color representation. 9. The module luminous flux is 3970 lm, and the luminaire luminous flux is 2803 lm, indicating the brightness of the light output. 10. The luminaire has a highluminous efficiency of 95.3 lm/W, ensuring energy-efficient operation. 11. During installation or relamping, avoid touching the light output opening of the LED directly to prevent damage to the high-quality electronic components. 12. To remove the synthetic cover, turn it anti-clockwise while simultaneously pushing it upagainst the luminaire fitting. 13. Replacement parts for the luminaire include a synthetic cover, shield, and LED unit, all with a colour temperature of 3000K.BEGA-51050-1-LED-Ceiling-Luminaire \(2\)

Application

Ceiling luminaire · indoor luminaire impact resistant synthetic diffuser and metal housing for non-glare light deflected downwards.

Product description

  • Ceiling luminaire »STUDIO LINE«
  • Aluminium luminaire housing, finish Colour velvet black inside hue white
  • Metal luminaire mounting plate, finish Colour velvet black
  • Impact resistant synthetic diffuser, white, with bayonet closure
  • 2 mounting holes ø 5.5mm
  • Distance apart 230mm
  • 2 cable entries for through-wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@
  • Connection terminal 2.5@
  • Earth conductor connection
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
    • c – Conformity mark
    • Weight: 2.4 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 26.4 W
  • Luminaire connected wattage 29.4 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=50 °C

51 050.1K3

  • Colour temperature 3000 K
  • Colour rendering index CRI >90
  • Module luminous flux 3970 lm
  • Luminaire luminous flux 2803 lm
  • Luminaire luminous efficiency 95,3 lm/W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.BEGA-51050-1-LED-Ceiling-Luminaire \(3\)

  • Before installing onto the ceiling the luminaire mounting plate must be inserted into the luminaire housing.
  • Thereby pass the mains supply cable through the grommet into luminaire mounting plate.
  • Fix monting plate inside the luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
  • Dismantle the mains supply cable approx. 60 mm.
  • Make earth and electrical connection to the terminals.
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • In order to securely install the synthetic cover in the fitting, the top opening of the synthetic cover must be inserted into the luminaire housing at an angle.
  • Make sure that at least one of the recesses in the edge of the synthetic cover matches the position of one of the lugs on the fitting – see drawing.

IMPORTANT:

  • Turn the synthetic cover upwards into the fitting as far as it will go. Now secure the synthetic cover in the fitting by turning it clockwise.
  • Only then is the synthetic cover held securely in place and resistant to vibration.
  • The synthetic cover is removed by turning it anti-clockwise as far as it will go while simultaneously pushing the synthetic cover up against the luminaire fitting.

Cleaning · Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Replacement of the LED unit\

  • The designation of the LED unit is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement units correspond to those of the
  • LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
  • Disconnect from main supply.
  • Unscrew synthetic diffuser from luminaire housing by turning it counter-clockwise.
  • Disassemble LED unit.
  • Assemble LED replacement unit.
  • Note installation instructions of the LED unit.
  • Screw in synthetic diffuser by turning it clockwise.
  • A damaged synthetic diffuser must be replaced.

Spares

  • Synthetic cover 15 000 633
  • Shield 71 003 503 B10
  • LED unit 3000 K 75 005 349 K3

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden