Application
Free-radiating ceiling and wall luminaire for many lighting tasks in or on
buildings.
Luminaire made of copper and thick-walled crystal glass.
Product description
Luminaire made of copper and stainless steel Crystal glass coated
2 mounting holes ø 6mm
Distance apart 153mm
1 cable entry for mains supply cable
up to ø 10,5mm
Lampholder terminal 2.5
Earth conductor connection
Lampholder E 27
Safety class I
Protection class IP 64
Dust-tight and protection against splash water
Impact strength IK07
Protection against mechanical
impacts < 2 joule
– Safety mark
– Conformity mark
Weight: 3.0 kg
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Lamp
Luminaire with screw base E 27
Lamp output max. 75 W
This product contains light source of energy efficiency class E
Supplied lamp
BEGA LED lamp 13588
LED Retrofit 8 W · 1055 lm · 3000 K
Luminaire efficiency: 54%
Additional BEGA LED lamps are available for this luminaire:
13 584 LED 7 W · 805 lm · 3000 K
13 586 LED 7 W · 805 lm · 3000 K
dimmable
13 590 LED 12 W · 1400 lm · 3000 K
13 592 LED 12 W · 1400 lm · 3000 K
dimmable
Detailed technical and lighting data for the lamps can be found in the data sheets on our website.
Installation
Please use the protective gloves provided for the installation to prevent
fingerprints on the luminaire.
Undo screws and remove the grid with glass from the luminaire back housing.
Lead the mains supply cable through the cable entry into the luminaire back
housing.
Fix the luminaire housing with enclosed or any other suitable fixing material
onto the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection. Insert
lamp.
Fix glass and guard with screws on luminaire back housing.
Make sure that gasket is positioned correctly.
Relamping · Maintenance
Disconnect the electrical installation.
Open the luminaire and clean.
Use only solvent-free cleaning agents. Change the lamp.
Check the gasket and replace, if necessary.
Close the luminaire.
For cleaning, do not use high pressure cleaners.
Copper
The luminaire parts made of solid copper are delivered with the metal’s
natural surface colour.
Time and weather factors create the natural patina characteristic for copper.
Spares
Spare glass 11 002 576 11
LED lamp 3000K 13 588
Lampholder 63 000 052
Gasket 81 000 325
References