Dimension
Instructions for use
Application
Unshielded luminaire for installation under ceilings, on walls as well as on
pillars and murals.
By means of the three-ply opal glass the light is distributed softly and
uniformly over the glass surface.
Product description
Luminaire made of aluminium alloy and stainless steel
BEGA Unidure® coating technology
Opal glass with screw neck 2 mounting holes ø 6mm
Distance apart 65mm 2 cable entries for through-wiring of mains supply cable ø
7-10.5mm
Connection terminal 2.5@
Earth conductor connection
Lampholder E 27
Safety class I
Protection class IP 65
Dust-tight and protection against water jets Impact strength IK02
Protection against mechanical impacts < 0.2 joule
– Safety mark
– Conformity mark
Weight: 2.8 kg
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Lamp
Luminaire with screw base E 27
Lamp output max. 100 W
This product contains light source of energy efficiency class E
Supplied lamp
BEGA LED lamp 13590
LED Retrofit 12 W · 1400 lm · 3000 K
Luminaire efficiency: 86%
Additional BEGA LED lamps are available for this luminaire:
13 584 LED 7 W · 805 lm · 3000 K
13 586 LED 7 W · 805 lm · 3000 K dimmable
13 588 LED 8 W · 1055 lm · 3000 K
13 592 LED 12 W · 1400 lm · 3000 K dimmable
Radio-controlled version (Zigbee 3.0):
13 555 LED 9 W · 805 lm · 2700 K dimmable
13 556 LED 9 W · 805 lm · 2700-6500 K dimmable · tunable white
13 557 LED 9.5 W · 805 lm · 2700-6500 K dimmable · tunable white · RGBW
Detailed technical and lighting data for the lamps can be found in the data sheets on our website.
Installation
Undo screws on circular blank of lampholder.
Remove circular blank of lampholder from luminaire base.
Lead the mains supply cable through the cable entry into the luminaire
housing.
In case of installation on a foundation, please observe the following: Wet
concrete can be highly alkaline and must not come into contact with the
luminaire permanently.
We recommend draining the installation area and painting it with insulating
paint.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Be sure to use the gasket rings supplied.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
Assemble circular blank of lampholder in luminaire base. Insert lamp.
Screw glass with gasket firmly into the luminaire base.
Make sure that gasket is positioned correctly.
Relamping · Maintenance
Disconnect the electrical installation.
Open the luminaire and clean.
Use only solvent-free cleaning agents. Change the lamp.
Check the gasket and replace, if necessary.
Close the luminaire.
For cleaning, do not use high pressure cleaners.
Spares
Spare glass with gasket: 11 002 262 41
LED lamp 3000K: 13 590
Lampholder: 63 000 105
Gasket glass: 83 000 219
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com