BEGA 51129 Indoor Wall Luminaire
Product Information
The product is a luminaire used for lighting purposes. It is designed to be installed and operated in accordance with national safety regulations. The installation and commissioning of the luminaire should only be done by a qualified electrician. The manufacturer does not accept liability for any damage caused by improper use or installation. The luminaire is equipped with electronic components that are protected against overvoltage in accordance with DIN EN 61547. Additional overvoltage protection components are recommended for enhanced protection against transients.
The luminaire has different module designations, colour temperatures, colour rendering indexes, module luminous flux, luminaire luminous flux, and luminaire luminous efficiency. The connected wattage for the lamp module is 11.6 W and the connected wattage for the luminaire is 13.4 W. The rated temperature is between 25°C and 55°C.
Product Usage Instructions
- Positioning the Glass:
- Place the glass over the luminaire fitting so that the retaining spring fits into the recess in the raised edge of the glass.
- Press the glass against the retaining spring at a flat angle and push it into the luminaire fitting.
- Gently apply pressure on the glass to fix it in place through the two lobes on the opposite side.
- Securing the Glass:
- Screw the grub screw (hexagon socket head wrench size 2.5) with gentle pressure against the retaining spring to securely hold the glass in place and make it resistant to vibration.
- If you need to change the orientation of the rotatable luminaire glass, loosen the grub screw.
- After adjusting the glass, screw the grub screw with gentle pressure against the retaining spring.
- Opening the Luminaire:
- Unscrew the grub screw (Allen screw) of the glass retaining spring of the luminaire fitting completely.
- Press the luminaire glass against the spring pressure of the glass retaining spring to release it from the luminaire fitting.
Application
- Closed and unshielded wall luminaire · Indoor luminaire made of hand-blown opal glass, satin matt and with metal fitting.
- Due to the soft and flowing shape of the glass, you can create seemingly random wall arrangements with other luminaires in this series.
- The luminaire glass can be rotated on the fitting.
Product Description
- Metal luminaire mounting plate, finish Colour white
- Lichtbaustein® · PEBBLES · Type A
- Hand-blown opal glass, satin matt
- 2 mounting holes ø 5.5 mm
- Distance apart 180 mm
- 2 cable entries for through-wiring for connection cable up to ø 10,5 mm max. 5 x 1.5@
- Connection terminal 2.5@
- Earth conductor connection
- LED power supply unit 220-240 V x 0/50-60 Hz
- DC 176-275 V
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Conformity mark
- Weight: 2.8 kg
- This product contains light sources of energy efficiency class(es) D, E
Safety
- The installation and operation of this luminaire are subject to national safety regulations.
- Installation and commissioning may only be carried out by a qualified electrician.
- The manufacturer accepts no liability for damage caused by improper use or installation.
- If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
- To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at www.bega.com.
Lamp Specification
- Module connected wattage 11.6 W
- Luminaire connected wattage 13.4 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 55 °C
51 129 K27
- Module designation LED-0509/927
- Colour temperature 2700 K
- Colour rendering index CRI > 90
- Module luminous flux 1670 lm
- Luminaire luminous flux 1161 lm
- Luminaire luminous efficiency 86,6 lm / W
51 129 K3
- Module designation LED-0509/930
- Colour temperature 3000 K
- Colour rendering index CRI > 90
- Module luminous flux 1725 lm
- Luminaire luminous flux 1200 lm
- Luminaire luminous efficiency 89,6 lm / W
Installation
- LED are high-quality electronic components!
- Please avoid touching the light output opening of the LED directly during installation or relamping.
- Lead the mains supply cable through the cable entry into the luminaire housing.
- Secure the luminaire fitting to the installation surface with the fixing materials provided or other suitable materials.
- Be sure to use the gasket rings supplied.
- Establish earth conductor connection and make the electrical connection to the terminals.
- For digital control please use the connecting terminal DA, DA.
- In case this terminal is not used the luminaire will be operated at full light output.
- Position the glass over the luminaire fitting so that the retaining spring fits into the recess in the raised edge of the glass.
- Press the glass against the retaining spring at a flat angle as far as it will go and push it into the luminaire fitting (see drawing).
- Gentle pressure on the glass will fix it in the luminaire fitting through the two lobes on the opposite side.
Dimension
IMPORTANT:
Screw the grub screw (hexagon socket head wrench size 2,5) with gentle
pressure against the retaining spring. In this way, the glass is held securely
in place and is resistant to vibration. If the orientation of the rotatable
luminaire glass on the fitting is to be changed, the grub screw must be
loosened. After adjusting the glass, screw the grub screw with gentle pressure
against the retaining spring.
Opening the luminaire
- Unscrew the grub screw (Allen screw) of the glass retaining spring of the luminaire fitting as far as it will go.
- The luminaire glass must be pressed against the spring pressure of the glass retaining spring in order to release it from the luminaire fitting.
Cleaning And Maintenance
- Clean luminaire regularly with solvent-free cleansers from dirt.
- Defective glass must be replaced.
Replacement of the LED module
- The designation of the LED module is noted on a label in the luminaire.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
- The module can be replaced by qualified persons using standard tools.
- Disconnect the system and open the luminaire.
- Please follow the installation instructions for the LED module.
- Defective glass must be replaced.
- Close the luminaire.
Spares
- Spare glass 11 003 593 .0R G
- LED power supply unit DEV-0402/500i
- LED module 2700 K LED-0509/927
- LED module 3000 K LED-0509/930
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com.