BEGA 33816 Wall Luminaire Instruction Manual

June 12, 2024
BEGA

BEGA 33816 Wall Luminaire

Product Information Product Name: Wandleuchte Wall luminaire Applique
Model Number: 33 816
Power: 40W
Voltage: 230V Light Distribution: Symmetrical
Application: Shielded wall luminaire with symmetrical light distribution, suitable for installation on columns and wall faces.
Dark Sky: The luminaire directs light evenly and efficiently onto the surface to be illuminated, emitting less than 1% of the luminaire luminous flux into the upper half-space of the luminaire.
Overvoltage Protection: The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547. Additional overvoltage protection components are recommended for protection against transients. These components can be found on the manufacturer’s website at www.bega.com.
Safety: The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should perform the installation and commissioning. The manufacturer is not liable for damage caused by improper use or installation. Any modifications made to the luminaire should be done by a responsible person who will be considered the manufacturer.

Lamp Information:

  • Module-Connected Wattage: 13.7W
  • Luminaire-Connected Wattage: 16W
  • Rated Temperature: 25°C
  • Ambient Temperature: 50°C

Module Information (K3):

  • Module Designation: LED-0341/830
  • Colour Temperature: 3000K
  • Colour Rendering Index (CRI): >80
  • Module Luminous Flux: 2600lm
  • Luminaire Luminous Flux: 1729lm
  • Luminaire Luminous Efficiency: 108.1lm/W

Module Information (K4):

  • Module Designation: LED-0341/840
  • Colour Temperature: 4000K
  • Colour Rendering Index (CRI): >80
  • Module Luminous Flux: 2670lm
  • Luminaire Luminous Flux: 1775lm
  • Luminaire Luminous Efficiency: 110.9lm/W

Product Usage Instructions

  1. Do not touch the light output opening of the LED directly during installation or relamping.
  2. Ensure that the gasket is positioned correctly.
  3. Create an earth conductor connection between the luminaire top and luminaire base.
  4. Install the luminaire top, press-on, and manually tighten screws evenly.

Wall luminaire

Instructions for use

Application
Shielded wall luminaire with symmetrical light distribution makes it particularly well-suited for installation on columns and wall faces.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite or silver
  • Safety glass with optical structure
  • Silicone gasket
  • Reflector made of pure anodised aluminium 2 mounting holes ø 4.5 mm
  • Distance apart 105 mm
  • 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@ Connecting terminal and  earth conductor terminal 2.5@
  • BEGA Ultimate Driver®
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 64
  • Dust-tight and protection against splash water Impact strength IK04
  • Protection against mechanical impacts < 0.5 joule
  • – Safety mark
  • – Conformity mark
  • Weight: 1.7 kg

This product contains light sources of energy efficiency class(es) C

Dark Sky
The light from this luminaire is directed evenly and highly efficiently onto the surface to be illuminated and emits less than 1 % of the luminaire luminous flux into the upper half-space of the luminaire.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

  • Module connected wattage 13.7 W
  • Luminaire connected wattage 16 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 50 °C

33 816 K3

  • Module designation LED-0341/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 2600 lm
  • Luminaire luminous flux 1729 lm
  • Luminaire luminous efficiency 108,1 lm / W

33 816 K4

  • Module designation LED-0341/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 2670 lm
  • Luminaire luminous flux 1775 lm
  • Luminaire luminous efficiency 110,9 lm / W

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

  • In outdoor areas, the light emission may only be directed downwards.
  • Undo the screws and lift off the luminaire top. Lead the mains supply cable through the cable entry of the luminaire base.
  • Note position of application of the luminaire “arrow down”.
  • Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
  • Be sure to use the gasket rings supplied. Make the earth conductor connection and the electrical connection.
  • For digital control please use the connecting terminal DA, DA.
  • In case this terminal is not used the luminaire will be operated at full light output.
  • In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
  • Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
  • Make sure that gasket is positioned correctly.
  • Make earth conductor connection between luminaire top and luminaire base.
  • Install the luminaire top, press-on and manually tighten screws evenly.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Spares

  • LED power supply unit DEV-0340/700
  • LED module 3000 K LED-0341/830
  • LED module 4000 K LED-0341/840
  • Reflector 76 001 391
  • Gasket 83 002 178

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals