BEGA 51037.5 Indoor Track Spotlight Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
51 037.5
Track spotlight for indoor use Instructions for use
Application
Ceiling mounted track spotlight · indoor luminaire for 3-phase Eurostandard-
Plus® track systems.
The optical system of the washer is swivel mounted and rotatable.
Symmetrical wide beam light distribution.
Optical filters are available as accessories for changing the light
distribution.
BEGA Hybrid Optics®: Highly efficient and low-loss light distribution, thanks
to reflector and optical lens.
Product description
GENIUS Track spotlight with adapter
Cast aluminium luminaire housing, finish Colour velvet black,
Polycarbonate track adapter with integrated LED power supply unit
Trim ring · Chrome finish
Safety glass, with internal optical filter
Optical silicone lens · BEGA Hybrid Optics®
Reflector surface made of pure aluminium
LED power supply unit
220-240 V y 50/60 Hz
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains
and control cables
Safety class II ****
– Conformity mark
Weight: 0.65 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
12,3 W | Module connected wattage |
---|---|
14,5 W | Luminaire connected wattage |
ta = 25 °C | Rated temperature |
ta max = 55 °C | Ambient temperature |
51 037.5 K3
LED-0986/930 | Module designation |
---|---|
3000 K | Colour temperature |
CRI > 90 | Colour rendering index |
1685 lm | Module luminous flux |
1215 lm | Luminaire luminous flux |
83,8 lm / W | Luminaire luminous efficiency |
51 037.5 K4
LED-0986/940 | Module designation |
---|---|
4000 K | Colour temperature |
CRI > 90 | Colour rendering index |
1710 lm | Module luminous flux |
1233 lm | Luminaire luminous flux |
85 lm / W | Luminaire luminous efficiency |
Light technique
Track spot · surface washer with adjustable optical system.
Optical system 0-340° swivel-mounted and ± 310° infinitely rotatable around
the vertical luminaire axis.
Symmetrical wide beam light distribution.
Half beam angle 28°
The symmetrical light cone can be changed to a flat beam, symmetrically
diffuse or asymmetrical light distribution for special lighting applications
by replacing the optical filter (standard) – accessoires.
For flat beam light distribution:
Optical filter 13 287
For symmetrically diffuse light distribution:
Optical filter 13 310
For asymmetrical light distribution:
Optical filter 13 309
The light cone can be adjusted by ±360° by turning the trim ring.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
The track spotlight with adapter is ready for operation in 3-phase
EUROSTANDARD-PLUS® track systems.
The mounting is done without tools in the bus bar.
IMPORTANT:
Ensure that the adapter’s two lateral stays are located on the same side as
the matching guide profile of the track before installing the adapter in the
3-phase EUROSTANDARDPLUS track system.
To select the phase ( 1 2 3 ) the turning knob on the rear side of the adapter
has to be operated accordingly.
Screw enclosed fastening ring (a) with attached reflector into the luminaire
housing by turning it clockwise until it stops, so that it is fixed by
clamping.
Clip the enclosed trim ring with glass and internal optical filter (b) onto the luminaire housing by applying slight pressure.
Place the surface washer adapter flush on the conductor rail in the desired
position.
Push the two fixing levers on the underside of the adapter to the right until
they click into their end position.
Set the desired LED beam direction by turning and tilting the luminaire
housing.
Move the two fixing levers in opposite directions until they disengage to
unlock the adapter.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system and open the luminaire.
Uninstall the reflector.
Please follow the installation instructions for the LED module.
Install the reflector. Defective glass must be replaced. Close the luminaire.
Accessories | Optical filters |
---|---|
13 287 | Optical filter flat beam |
13 310 | Optical filter symmetrical, diffuse |
13 309 | Optical filter asymmetrical |
For the accessories a separate instructions for use can be provided upon request.
Spares
15 000 683 | Prismatic film |
---|---|
20 000 106 B6 | Fastening ring reflector |
DEV-0438/350i | LED power supply unit |
LED-0986/930 | LED module 3000 K |
LED-0986/940 | LED module 4000 K |
75 004 444 | Reflector unit |
75 004 843 | Trim ring with glass |