BEGA 51263.1 Wall Luminaire Instruction Manual
- June 12, 2024
- BEGA
Table of Contents
Technical amendments reserved
Wall luminaire for indoor use
51 263.1
51263.1 Wall Luminaire
Instructions for use
Application
Wall luminaire · indoor luminaire with light emission on two sides for the
glare free illumination of wall surfaces with the mounting surface being the
reflection surface.
A luminaire which allows interesting illumination concepts individually or in
rows.
Product description
Luminaire housing made of aluminium, finish Colour velvet white
Silicone light diffuser 3 elongated fixing holes
Width 4.5 mm · 895 mm spacing
Mounting plate with several openings for cable entry and through-wiring for
mains cable
Connecting terminals 2.5@
Earth conductor connection
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-276 V
During DC operation the LED power is reduced to 15 %
DALI-controllable
Number of DALI addresses: 2
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
****– Conformity mark
Weight: 7.3 kg
This product contains light sources of energy efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage | 69.4 W |
---|---|
Luminaire connected wattage | 77 W |
Rated temperature | ta = 25 °C |
Service life criteria | 50 000 h / L70 |
51 263.1 K3
Module designation | 2x LED-1321/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 10800 lm |
Luminaire luminous flux * | 7070 lm |
Luminaire luminous efficiency | 91,8 lm / W |
- preliminary data
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Undo the hexagon socket head screws (wrench size 3 mm) and lift luminaire
housing.
Loosen earth connection (plug connection) between luminaire housing and
mounting plate.
Pass the power connecting cable through one of the openings of the mounting
plate.
Fasten the mounting plate with the supplied fastening material or other
suitable fastening material to the installation surface.
Make the electrical connection to the terminals. Please ensure correct wire
assignment for the connecting cable.
Connect the earth conductor to the greenyellow wire ( ). Connect the live
conductor to the brown wire (L) and the neutral conductor to the blue wire
(N).
Use the terminals marked DA, DA for digital control.
If these terminals are not used, the luminaire will operate at full light
output.
Make earth connection (plug connection) between luminaire housing and mounting
plate again.
Hang the luminaire housing in the mounting plate and screw it in place with
the hexagon socket head screws.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system from the power supply.
Press the synthetic LED cover together lengthwise and remove it from the
housing profile.
Remove the LED module. Install the replacement LED module.
Please follow the installation instructions for the LED module.
A defective LED cover must be replaced.
Spares
LED power supply unit | DEV-0159/700i |
---|---|
LED module 3000 K with diffusor | LED-1321/930 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>