SLV 1006431 …32 Pendant Light Instruction Manual
- June 12, 2024
- SLV
Table of Contents
SLV 1006431 …32 Pendant Light
Tools
Info
1006431 …32|
GU10
| 1x|
10W max.
|
Ø 7 x 12,5 cm
| 0,50 kg
---|---|---|---|---|---
1006433 …34| 2x| 0,98 kg
1006435 …36| 3x| 1,44 kg
1006437 …38| 4x| 2,00 kg
Symbols
Installation Instructions
Warning: The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
Technical Details are subject to change.
Pendant Light
- 1006431 …32 1006433 …34 1006435 …36 1006437 …38
Using Instructions
- Read manual carefully and keep for further use!
- Safety advices for installation and operation.
- Disregard may lead to danger of life, burning or fire!
- Any works on the electrical connection only by electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
- Take measures that children get not harmed by the product.
- Additional safety advices =
Use as directed
- Safety class I (1) – Connection with protective conductor.
- Operate only firmly fixed on an even surface.
- Operate only on normal or not inflammable surfaces.
- Operate only in dry indoor area.
- Do not strain mechanically or expose to strong dirt contamination.
Lamp replacement
- Disconnect the luminaire from the mains and let it cool down.
- Suitable light sources: GU10, 10W max.
Care / Storage
- Disconnect product from mains and let it cool down.
- Clean external surfaces regularly with a slightly moistened (water) cloth.
- Store dry and clean.
Installation
- Switch off mains / fixed connection cable!
- Use only described accessories.
- Use only suitable fastening materials.
- Only suited for ceiling surface mounting.
- Install as shown in the figure.
- Adapting the pendant cable: Loosen strain relief(A). Disconnect wires and cut the pendant cable. Connect as before (attach wire end ferrules if necessary!). Secure strain relief. Carry out a continuity test after shortening the pendant cable.
Electrical connection
Equip flexible wire ends with suitable wire ferrules!
- Live conductor Terminal L
- Neutral conductor Terminal N
- Protective conductor Earth terminal
Warning: Check secure fixation and proper function!
Contact
SLV GmbH
- Daimlerstr. 21-23, 52531 Übach-Palenberg, Germany.
- Tel. +49 (0)2451 4833-0.
Made in China.
SLV UK
- Unit E Chiltern Park
- Boscombe Road, Bedfordshire LU5 4LT
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>