HORMANN Aluminium Entrance Door Instruction Manual
- October 30, 2023
- HORMANN
Table of Contents
- HORMANN Aluminium Entrance Door
- Product Information
- Product Usage Instructions
- PRODUCT Safety Precautions
- PRODUCT Cleaning and Maintenance
- PRODUCT Disassembly and Disposal
- About These Instructions
- Safety Instructions
- Fitting
- Description of S5 Smart / Comfort / Code / Scan
- Inspection and Maintenance
- Cleaning and Care
- Dismantling and Disposal
- Spare Parts
- INSTALLATION INSTRUCTION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HORMANN Aluminium Entrance Door
Product Information
This product is an aluminum entrance door that comes with instructions for fitting, operating, and maintenance. It includes information on safety precautions, installation methods, and cleaning and maintenance procedures. The product also features ECO-Dualverriegelung and LED-Anzeige.
Product Usage Instructions
Before installing or using the Aluminium Entrance Door, carefully read the instructions in this manual to ensure proper usage and avoid accidents or damage to the product.
PRODUCT Safety Precautions
- Only qualified personnel should install the door.
- Follow all safety warnings and symbols in the manual.
Installation
- Choose the appropriate installation method for your door.
- Adjust the fittings according to the instructions.
- Install glazing according to the instructions.
ECO-Dualverriegelung
Adjust the mechanical lever as shown in Bild 15d for ECO-Dualverriegelung.
LED-Anzeige
- Learn how to program a wireless code.
- Activate the wireless codes according to the instructions.
PRODUCT Cleaning and Maintenance
- Clean all movable parts regularly.
- Check and maintain the cylinder.
PRODUCT Disassembly and Disposal
If you need to disassemble or dispose of the door, follow the instructions in this manual. For further information or technical support, please see the manufacturer’s instructions.
Dissemination, as well as duplication of this document and the use and communication of its content, are prohibited unless explicitly permitted. Noncompliance will result in damage compensation obligations. All rights reserved in the event of patent, utility model or design model registration. Subject to changes. Dear customer, We are delighted that you have chosen a high-quality product from our company.
About These Instructions
These instructions are divided into a text section and an illustrated section. The illustrated section can be found after the text section. These instructions are original operating instructions in accordance with EU-BpVO 305/2011. Please read and follow these instructions carefully, as they contain important information on the fitting, operation and correct care/maintenance of the aluminium entrance door so that you can enjoy this product for many years to come. Please pay particular attention to all safety and warning notices. Keep these instructions in a safe place for later reference! Skilled fitting and thorough maintenance increase performance, availability and safety. The texts and diagrams in this manual have been created with the greatest care possible. In order to provide a concise overview, not all detailed information on all variants and possible assemblies can be described. The texts and diagrams published in this manual are merely intended as examples. Any guarantee for its completeness is excluded and does not justify a complaint. Should you desire more information, or if special problems occur which are not described in detail in the manual, you may request information from the manufacturing plant. These instructions are an important document for the construction file.
Warnings used
-
DANGER
Indicates a danger that leads directly to death or serious injuries. -
ATTENTION
Indicates a danger that can lead to damage or destruction of the product.
Symbole used
Abbreviations used
- OFF (FFL) Finished floor level
Colour code for leads, single wires and components
The colour abbreviations for lead, wire and component identification follows
the international colour code in accordance with IEC 757:
BK | black | YE | yellow |
---|---|---|---|
BN | brown | WH | white |
GN | green | GN / YE | green / yellow |
GY | grey |
Safety Instructions
DANGER
Mortal danger when fitting entrance door
During fitting, the door or door frame can fall and kill persons.
- Prior to and during fitting, secure the door and frame against falling over.
- Comply with the basic rules of DIN 4108 Thermal protection and energy economy in buildings when fitting the aluminium entrance door.
- Make sure to comply with the applicable standards, directives, regulations, ordinances and the generally accepted rules of technology.
- Protect your aluminium entrance door until construction is completed by covering it with foil to prevent damages. However, please note that, especially with extensive exposure to sunlight, adhesive tape may leave residues.
- Identify suitable fastenings according to the local conditions and have them on hand.
- Anchor the aluminium entrance door to all provided fixing points in the wall.
- Always maintain the required edge and centre line spacing of the plugs depending on wall type, as well as the fitting information and handling guidelines of the plug manufacturer!
- Contact surfaces to be sealed with silicon and sealant material must first be cleaned, such as
- Profile surfaces
- Edge compound of the pane
- Only use adhesive and sealant materials that are suitable for this application and compatible with the product materials. Follow the handling guidelines of the respective manufacturer.
- Electrical work may only be carried out by qualified electricians.
- EC Directive 2006/42/EG must be complied with for aluminium entrance doors with automatic door operators.
Fitter qualification
In order to ensure proper installation of the aluminium entrance door, only
fitters with commensurate training may be charged with the task.
ATTENTION
Impaired function
Missing or modified components will impair the function of the entrance door.
- Do not alter or remove any components.
- Fasten all components described in the manual.
Fitting
- To ensure simple and professional fitting, carefully go through all the work steps shown in the illustrated section.
- Before fitting the door, check whether any attached parts have to be fitted.
- Remove the transport protection before fitting
- Fastening and sealing materials are not included in the scope of delivery.
NOTE:
It is important that you use the fixing points prepared at the factory. The
fixing points indicated in the fitting instructions are only general and may
deviate from the fixing points prepared at the factory.
Accessories
- K3 door / side element / transom light
- VP25 / VP50 extension
- VP100 / VP150 extension
- VPE20 / VPE50 one-piece extension
- KE135 / KE90 corner profiles 135º / 90º (see Figures 3.4) KS3 static profile (see Figure 3.5)
- Fixing material for accessories is part of the scope of delivery.
Determining the door position
- Determine the door position depending on the on-site fastening options, type of wall and the required edge and centre line spacing for the plug.
- If possible, position the door so that it is within the insulation layer of the wall. With monolithic or single-shell brickwork, position the door as close as possible towards the building interior side. Observe the isothermal lines (see Figure 1).
Fitting types
- Anchor fitting (see Figures 9 – 12)
- Plug-and-screw fitting (see Figures 9 – 12)
- Frame screw fitting (see Figures 9 – 12)
NOTE:
Each fixing point must be back-blocked resistant to pressure.
- Unhinge the door leaf (see Figures 2.5 / 15 / 21).
ATTENTION
Impaired function
Non-compliance with the handling guidelines will impair the function of the
entrance door.
- With fixing and sealant material, follow the handling guidelines of the respective manufacturer.
Connection to building structure
Proper fastening and sealing of the connection joint to the building structure
is a fundamental prerequisite for permanent usability of the door. It depends
on the respective exterior wall system and fitting situation. Comply with the
requirements of the current EnEV, the specifications of the RAL quality
monitoring association for windows and doors e.V. and the manufacturer‘s
processing guidelines.
The following generally applies:|
---|---
Room side| Air and vapour diffusion-tight seal
Average range| Thermal insulation unsusceptible to moisture
Exterior side| Vapour diffusion-open wind and rain barrier
Adjusting the fitting
- Horizontal and vertical door leaf adjustment, contact pressure adjustment.
ATTENTION
Limiting the door opening angle (see Figure 15c.1) The door opening angle must
be limited to 105˚ on site.
- Note that for concealed hinges, the door opening angle must be limited to 105 , as otherwise damage to the hinge or door frame can be expected.
Eco double-locking, adjustment of the mechanical rocker (see Figure 15d)
The mechanical rocker is used as standard for double-leaf doors. Due to the
rocker function, the fixed leaf is always unlocked simultaneously with the
opening of the traffic leaf.
Lever handle
- Lever pin 9 mm
- For doors in escape and rescue routes it should be ensured that the fitting is approved acc. to DIN EN 179 or DIN EN 1125.
Overhead door closer (GEZE)
- Fitting on the hinge side / standard fitting (see Figure 16a).
- Fitting on the opposite hinge side / head fitting, schematic diagram (see Figure 16b).
- Also see the fitting instructions of the closer type provided with the accessory pack.
- In general, overhead door closers with a certificate of conformity can be fitted. The standards EN 1154 and EN 1155 apply.
- The selection of the closer is determined by the door leaf weight and the door leaf width.
- A restrained opening in the overhead door closer is recommended. Overhead door closers may only be fitted with suitable mounting plates.
- The fitting holes for the mounting plates and slide rails are prepared at the factory.
- The overhead door closer including the mounting plates and slide rails are supplied separately.
- The “regulations for hold-open devices” must be observed for overhead door closers with hold-open device (integrated or magnetic).
- The closer must be set in such a way that the door closes “evenly and gently” within 5 ±2 seconds from a 90° opening angle.
Glazing
- Insertion and replacement of the glass panes or infills (see Figures 13 / 14 / 20).
- Blocking suggestions (see Figures 13 / 14 / 20)
- Secure blocking against falling (e.g. with Pattex adhesive).
Electrical connections
DANGER
Mains voltage!
Contact with the mains voltage presents the danger of a deadly electric shock.
For that reason, observe the following warnings under all circumstances:
- Electrical connections may only be performed by a qualified electrician!
- The on – site electrical installation must conform to the applicable protective regulations!
- Qualified electricians must ensure compliance with the national directives for the operation of electrical devices!
Depending on the length of the power supply cable, it must have at least the following cross-section:
10 m | 0,50 mm2 | 75 m | 1,50 mm2 |
---|---|---|---|
40 m | 0,75 mm2 | 125 m | 2,50 mm2 |
50 m | 1,00 mm2 |
Fitting break-in-resistant door sets
The fitting instructions in this section give additional tips on fitting
break-in-resistant door sets with resistance classes RC2, RC3 acc. to DIN EN
1627: 2011 (see Figures 20 / 21). Only by a professional fitting in accordance
with these instructions will the door sets be equipped with break-in-resistant
features.
Permissible walls
The required break-in-resistance can only be obtained if the adjacent walls
meet the requirements according to Tab. 1 – Tab. 3.
Permissible wall connections
The wall connections defined in Image 9.2 are permissible. Expert fitting must
be verified with a fitting certificate.
Safety relevant components
The required break-in – resistance can only be obtained if the used infills
meet the following requirements.
The minimum requirement for the side element/transom light infills:
Resistance class | RC2 | RC3 |
---|---|---|
Glazing resistance class according to EN 356 | P4 A | P5 A |
Placement of the safety pane | Opposite side | Attack side |
Panel with or without glass | Aluminium panel |
The exchange of security-relevant components during improper fitting (e.g.
fittings, locks and infills) can lead to a loss of door set resistance.
Minimum requirements for the fittings:
Resistance class | RC2 | RC3 |
---|
EN 1303 (see Figure 20 ) Locking cylinder (position 7) Locking cylinder (position 8)|
4
1
|
4
1
EN 1906
Protective fitting (position 7)
|
Integrated into the construction
EN 12209
Locks (position 7)
|
3 1)
|
4 1)
- The suitability of the locks must additionally be verified through tests according to DIN EN 1627 or as part of an expert’s opinion. Be sure to observe the following fitting instructions:
- The visible gap of 5 ± 1 mm between frame and leaf must be observed (see Figure 15) so that the lock bolts fully extend into the lock plate openings.
Tab. 1: Classification of the resistance classes of break-in-resistant components for solid walls
__
Resistance class of the component acc. to
DIN EN 1627
| Surrounding walls
---|---
In brickwork according to DIN 1053-1| Reinforced concrete walls acc. to DIN
1045
Wall thickness (unplastered)| Compression strength class of the bricks (DFK)|
Apparent den- sity class of the bricks (RDK)| Mortar group| Nominal thick-
ness| Strength class
RC2| __
≥ 115 mm
| __
≥ 12
| __
–
| __
min. MG II/DM
| min. 100 mm| __
min. B 15
RC3| min. 120 mm
Tab. 2: Classification of the resistance classes of break-in-resistant components for gas concrete walls
Gas concrete wall
Resistance class| Compression strength class of the bricks| Nominal thickness|
Version
RC2| __
≥ 4
| ≥ 170 mm| __
Bonded
RC3| ≥ 240 mm
Tab. 3: Classification of the resistance classes of break-in-resistant components for timber panel walls
Prefabricated and timber partition walls with respective resistance class suitability certification from the manufacturer.
Additional instructions for fitting
- Install the frames vertically and properly aligned (see Figure 10).
- In the areas described below, back-fill the spaces between the frame and walls with a rot-free material to withstand pressure:
- Hinges
- Infill
- Locking
- Fixing points
- On the upper and lower corners
By taking suitable precautions (e.g. silicone), make sure that the pressure- resistant back-packing is not able to shift (see Figure 9.2).
Instructions for the user
- Break-in-resistant components only provide burglar resistance in a closed, locked, and secured state and when the key has been removed!
- Anti-panic locks are not permissible in combination with break-in-resistant doors!
- Knob and round cylinders are not generally permitted in break-in-resistant doors (RC2, RC3).
Guarantee
To ensure the performance criterion “break-in resistance in accordance with
DIN EN 1627” with classification RC2, RC3 the fitting company must confirm
expert fitting in accordance with these instructions by means of the document
“Fitting certificate for break-in-resistant doors” provided with the order
confirmation and return this document filled out to the manufacturer.
Description of S5 Smart / Comfort / Code / Scan
Volt-free control of the locks (see Figure 6b) If the locks are to be controlled via intercom/buttons to which voltage is applied at the output, this cable must be switched to volt-free by fitting a coupling relay. Coupling relay for standard cases (12 V AC) in accessories.
ATTENTION
The factory code must be changed for the initial start-up of the finger-scan
or code switch.
- See the included manufacturer operating instructions.
LED display Blue (BU)
Condition | Function |
---|---|
Illuminated briefly | A valid radio code was disco- vered for channel 1 |
Illuminated long once | A valid radio code is discovered that has been stored |
on both channels
Flashes slowly| Receiver is in the learn mode for channel 1
Flashes quickly after slow flashing| A valid radio code was disco- vered
during the learning
Flashes slowly for 5 seconds Flashes quickly for 2 seconds| Device reset is
being imple- mented or completed
Off| Operation mode
Programming button P (P button)
Teaching in a radio code
To activate / switch a channel:
- Press the P button once to activate channel 1. To abort the learn mode:
- Press the P button 3 times, or wait for the timeout.
Timeout
If no valid radio code is recognised within 25 seconds, the receiver
automatically returns to the operation mode.
Teaching in a radio code (see Figure 6f)
- Press the P button to activate the desired channel.
- The blue LED will flash slowly for channel 1.
- Put the hand transmitter, whose radio code is to be inherited, into the Inheriting / Transmitting mode. If a valid radio code is recognized, the LED flashes quickly in blue and then goes out. The receiver is in the operation mode.
Operation
In the operation mode, the receiver signals the recognition of a valid radio
code by illuminating the blue LED.
NOTE:
If the radio code for the taught-in hand transmitter was copied from another
hand transmitter, the hand transmitter button must be pressed a second time
during initial start-up. A valid radio code channel 1 is discovered = The LED
is illuminated briefly once
Reset
All radio codes are deleted by the following steps:
- Press and hold the P button.
- The LED slowly flashes in blue for 5 seconds.
- The LED flashes rapidly in blue for 2 seconds.
- Release the P button. All radio codes have been deleted.
NOTE:
If the P button is released prematurely, the device reset will be aborted and
the radio codes are not deleted.
Inspection and Maintenance
Checking the seating and sealing
Correct fitting of the aluminum entrance door must be checked before
concluding the fitting.
- Check the following points:
- Tightness of the fitting screws to the building structure
- Aluminum entrance door seal to the building structure
Cleaning and Care
Surface
You have purchased a high – grade aluminum product. Protect it by performing
cleaning and upkeep regularly. This is the only way to prevent undesired
corrosion caused by environmental conditions and contamination related to use.
Wash surfaces with a mixture of alcohol and water before bonding.
ATTENTION
Unsuitable care products
The door surface and adjacent components can be damaged by aggressive, corrosive or abrasive materials such as acids or steel brushes.
- Only use conventional care products and microfibre cloths to clean the aluminum entrance door.
- Use water to rinse any dirt off high-gloss surfaces.
- Never use polish on matt surfaces.
- Always take note of the manufacturer information for the care products.
Note :
Manufacturer‘s recommendation: proWIN “Seidenglanz” detergent in conjunction
with the proWIN “Hochglanzzauber” microfiber cloth.
www.prowin.net
Movable fitting parts
- Oil or lubricate moveable fitting parts once per year. Only use acid-free oil or Vaseline.
Door hinges
ATTENTION
Lubricating the door hinges
Lubricate concealed door hinges after 50,000 locks at the latest.
- Surface-mounted door hinges are maintenance-free.
- Never lubricate these door hinges.
Cylinder
To maintain the closing cylinder, only special cylinder care spray is
approved. Do not use products that contain graphite under any circumstances.
Dismantling and Disposal
Dismantling the aluminum entrance door is done in the reverse order of the assembly. To dispose of it properly after dismantling, the aluminum entrance door must be disassembled into its individual components and disposed of according to local official regulations.
Spare Parts
We advise explicitly that only genuine spare parts are tested and approved. The following cylinders may be used in conjunction with our locks H5 / S5 :
- Knob cylinders
- Cylinders with/without compensator function
- Cylinders with/without emergency and hazard function
If using other locks, such as gear locks with anti-panic function, proper function in conjunction with the desired cylinder must be checked and ensured in advance.
INSTALLATION INSTRUCTION
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>