MEAN WELL PLM-25 Series 25W Single Output LED Power Supply User Guide
- August 15, 2024
- MEAN WELL
Table of Contents
MEAN WELL PLM-25 Series 25W Single Output LED Power Supply
Product Usage Instructions
Installation
- Ensure the input voltage is within the specified range.
- Connect the output wires to the LED device, ensuring correct polarity.
- Securely mount the power supply in a well-ventilated area to prevent overheating.
Operation
- Apply the input power within the specified voltage and frequency range.
- The power supply will regulate the output current based on the connected LED device’s requirements.
Maintenance
- Periodically check for any loose connections or signs of damage.
- Clean the power supply unit regularly to prevent dust accumulation.
Frequently Asked Questions (FAQ):
Q: What should I do if the power supply overheats?
A: If the power supply overheats, immediately disconnect the input power and
allow it to cool down before resuming operation.
25W Single Output LED Power Supply
Features
-
230VAC only or Full range (up to 295VAC) models available
-
Built-in active PFC function
-
Constant current design
-
Protections:Short circuit
Cooling by free air convection -
Fully isolated plastic case • Class II power unit, no FG
-
Class 2 power unit(for PLM-25-500/700/1050)
-
No load power consumption <0.5W
-
High reliability,low cost
-
2 years warranty
Applications
- Indoor LED lighting
- LED office lighting
- LED commercial lighting
- LED decorative lighting
GTIN CODE MW
Search: https://www.meanwell.com/serviceGTIN.aspx
Description
PLM-25 is a 25W economical AC/DC LED power supply series. Incorporating a
built-in active PFC design, PLM-25 provides a high Power Factor value greater
than 0.9. In addition, with the low no load power consumption below 0.5W, and
the setup time less than 500ms, PLM-25 is complied with the ErP regulation
required by European Union for lighting fixtures. PLM-25 is a class II
(without FG pin) power unit housed with the UL 94V-0 rated flame retardant
plastic case. The 1/0 terminals are designed with screw-less clamp style
terminal block that greatly simplifies the wiring installation. Two types of
models with different input voltage range are offered: PLM-25 series, which
operates from 110~295VAC, and PLM-25E series, which operates from 180~295VAC.
These two series are both constant current output design, supplying models
with the current of 350mA, 500mA, 700mA and 1050mA, respectively.
Model Encodina
SPECIFICATION
MODEL| PLM-25 -350| PLM-25 -500| PLM-25 -700| PLM-25
-1050
---|---|---|---|---
OUTPUT| CONSTANT CURRENT REGION Note.5| 42 ~ 72V| 30 ~
50V| 21 ~ 36V| 14 ~ 24V
RATED CURRENT| 0.35A| 0.5A| 0.7A| 1.05A
NO LOAD OUTPUT VOLTAGE (max.)| 80V| 56V| 42V| 28V
RATED POWER| 25.2W| 25W| 25.2W| 25.2W
RIPPLE & NOISE
(max.) Note.2
| Blank type| 7.2Vp-p| 5.0Vp-p| 3.6Vp-p| 2.4Vp-p
E type| 9Vp-p| 7.5Vp-p| 5.4Vp-p| 3.6Vp-p
CURRENT ACCURACY Note.3| ±5.0%
SETUP TIME| Blank type: 500ms / 115VAC, 230VAC at full load; E
type: 500ms / 230VAC at full load
INPUT| VOLTAGE RANGE Note.4| Blank type: 110 ~ 295VAC
156 ~ 417VDC; E type: 180 ~ 295VAC 254~ 417VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR
| Blank type| PF≥0.97/115VAC,PF≥0.95/230VAC,PF>0.9/277VAC(at full
load)(Please refer to “Power Factor Characteristic” curve)
E type| PF≥0.95/230VAC,PF≥0.9/277VAC (at full load)(Please refer to
“Power Factor Characteristic” curve)
TOTAL HARMONIC DISTORTION| Blank type| THD< 20% when output
loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
E type| THD< 20% when output loading≧60% at 230VAC input and output
loading≧75% at 277VAC input
EFFICIENCY
(Typ.)
| Blank type| 87%| 86%| 86%| 85%
E type| 86%| 85%| 85%| 82%
AC CURRENT| Blank type: 0.3A/115VAC 0.15A/230VAC 0.12A/277VAC; E
type: 0.15A/230VAC 0.12A/277VAC
INRUSH CURRENT(Typ.)| COLD START 15A(twidth=50μs measured at 50% Ipeak)
at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 80 units (circuit breaker of
type B) / 80 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC
PROTECTION| SHORT CIRCUIT| Hiccup mode, recovers automatically
after fault condition is removed.
ENVIRONMENT| WORKING TEMP.| -30 ~ +45℃
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.06%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & EMC| SAFETY STANDARDS| UL8750, CSA C22.2 No. 250.13-12(for
Blank type only); ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, BS
EN/EN62384,GB19510.14,GB19510.1(for E type only),EAC TP TC 004, IP30 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms/500VDC / 25℃/ 70%RH
EMC EMISSION| Compliance to BS EN/EN55015, GB/T 17743,GB17625.1(for E
type only),BS EN/EN61000-3-2 Class C(≥60% load); BS EN/EN61000-3-3,EAC TP TC
020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS
EN/EN61547, light industry level, criteria B(surge 2KV),EAC TP TC 020
OTHERS| MTBF| 7905.4K hrs min. Telcordia SR-332 (Bellcore) ;
608.9Khrs min. MIL-HDBK-217F (25℃)
DIMENSION| 1453822mm (LWH)
PACKING| 0.126Kg;60pcs/8.6 Kg/0.48CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Please see “AC input voltage drop vs. output current characteristics” table.
- Derating may be needed under low input voltage, please check the static characteristic for more details.
- Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf
- Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
- ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
Block Diagram
Derating Curve
Static Characteristics
Power Factor Characteristic
EFFICIENCY vs LOAD (500mA Model)
AC input voltage drop vs. output current characteristics
AC input drop | 10% | 8% | 5% | 3% |
---|---|---|---|---|
Io drop | <16% | <12% | <8% | <7% |
NOTE: Output current will return to the rated value within 50ms