Product Information
Specifications
- Product: Sectional Garage Doors
- Door Types: LTH 42, LPU 42
- Material: Double-skinned steel sections, Woodgrain, Slate, Deco, Silk, Sandgrain
- Frame: Aluminium NF/WF
- Glazing Type: D, Panel Glazing S0, S1, S2, Sunrise, M0, LD
- Size Range: Door width in 1 mm increments up to LZ = 5500 mm
Product Usage Instructions
Installation Preparations
Before fitting a sectional door, ensure that the door opening is finished and the garage floor is laid and level according to country-specific building regulations.
Sectional Door LTH 42 Usage
The Sectional door LTH 42 is suitable for standard door leaf constructions and can be equipped with special styles like Nordic Pine. Refer to the brochure material for additional details.
Sectional Door LPU 42 Usage
The Sectional door LPU 42 features double-skinned steel sections with various ribbing options. It can be customized with different finishes like Woodgrain, Slate, Deco, Silk, or Sandgrain. The door comes in standard sizes and can be fitted with aluminium frames and different glazing types.
FAQs
- Q: Can the sectional doors be customized for non-standard sizes?
- A: Yes, the sectional doors can be customized for non-standard sizes as per the specifications provided in the manual.
- Q: Are there specific maintenance requirements for these doors?
- A: Regularly clean and lubricate the moving parts of the doors to ensure smooth operation. Refer to the maintenance section of the manual for detailed instructions.
“`
Technical manual As of 01.03.2024
Sectional garage doors
Table of contents
Contents
Door type / leaf, door type / leaf LPU 42, S-ribbed, Woodgrain LPU 42,
M-ribbed, Wood-, Slate-, Silk-, Deco- or Sandgrain LPU 42- L-ribbed, all
surface finishes LPU 42, D-ribbed, Silkgrain LPU 42, S-panelled, Woodgrain ART
42 aluminium ART 42 Vitraplan LPU 67 Thermo, M- / L-ribbed, Silk- or Decograin
Sunrise glazing LPU 42 Design element LPU 67 Silk- and Decograin, LPU 42 all
surface finishes Design element LPU 42, D- / M-ribbed LPU 42 with wicket door
without threshold rail, S- / M- / L- / D-ribbed LPU 42 with wicket door
without threshold rail, S-panelled, Woodgrain LPU 42 with wicket door without
threshold rail, arrangement of the wicket door LPU 42 with wicket door and
threshold rail / high threshold rail, S- / M- / L- / D-ribbed, LPU 42 with
wicket door and threshold rail, S-panelled, Woodgrain LTH 42, S- / M- /
L-ribbed, V-panelled LTH 42 with special styles Track application Z Track
application N Track application L Track application H Track application Z with
wicket door with trip-free threshold Track application Z with wicket door and
high threshold rail Track application N with wicket door without threshold
rail Track application N with wicket door and high threshold rail Track
application L with wicket door without threshold rail Track application L with
wicket door and high threshold rail Track application BZ Track application BZ
with wicket door without threshold rail Track application BZ with wicket door
and high threshold rail Track application BL Track application BL with wicket
door without threshold rail Track application BL with wicket door and high
threshold rail Siderooms Fitting solutions with side door NT 60, fixed element
and LPU 42 Sideroom and lintel fitting, ThermoFrame Sideroom and lintel
fitting LTH 42 Lintel fitting with fascia panels Bottom edge Fixed elements
Side doors NT 60 with corner frame made of aluminium profiles, standard and
special sizes Side doors NT 60 with block frame made of aluminium profiles,
standard sizes Side doors NT 60 with block frame made of aluminium profiles,
special sizes Double-leaf side doors NT 60 with block frame made of aluminium
profiles Side doors NT 60 ART 42 with corner frame made of aluminium profiles
Side doors NT 60 ART 42 with block frame made of aluminium profiles Double-
leaf hinged door DFT 42 with block frame made of aluminium profiles
Page
3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 19 20 21 22 23 24 25 26 27 29 30 32 33 35
36 37 38 39 40 41 42 43 44 45 46 47 48 49 52 53 54 55 56 57 58 60 61 62
63 64 65 66 67 68 69 70 71 72 73
Always take the country-specific building regulations into account. Door leaf
constructions and track applications as well as fitting examples are provided
in this manual.
Before fitting a sectional door, the door opening must be finished and the
garage floor must be laid and level.
No part may be reproduced without our prior permission All rights reserved All dimensions in mm Subject to design changes
2
Technical manual: Sectional garage doors / 03.2024
Door type
Door leaf
Sectional door LPU 42 double-skinned steel sections
· S-ribbed, Woodgrain · M-ribbed, Wood-, Slate-, Silk-, Deco-
or Sandgrain
· L-ribbed, Wood-, Slate-, Silk-, Deco-, Sand- or Duragrain, Planar
· D-ribbed, Silkgrain
· Double-skinned, PU-foamed door sections, Wood-, Slate-, Silk-, Deco-, Dura-
or Sandgrain, Planar exterior, Stucco-textured interior
· Door sections of equal height, horizontally ribbed or without ribbing, made
of hot-galvanized sheet steel
· Surface finish with high-quality coating on both sides
Decograin version with plastic film coating on the outside
For Duragrain decor with high-strength, high-quality coating, authentic
exterior surface finish look
· S-panelled Woodgrain
· Double-skinned, PU-foamed door sections, Woodgrain exterior, Stucco-textured
interior · Hot-galvanized sheet steel door sections of equal height with
panelling · Surface finish with high-quality coating on both sides (Decograin
version with high-quality
plastic film coating on the outside)
Sectional door LPU 67 Thermo double-skinned steel sections with thermal break
· M-ribbed, Silk- or Decograin · L-ribbed, Silk- or Decograin
· Double-skinned, PU-foamed door sections with thermal break, Silk- or
Decograin exterior, Stucco-textured interior
· Door sections of equal height, horizontally ribbed or without ribbing, made
of hot-galvanized sheet steel
· Surface finish with high-quality coating on both sides (Decograin version
with high-quality plastic film coating on the outside)
Sectional door LPU 42 with wicket door double-skinned steel sections
· M-ribbed, Wood-, Slate-, Silk-, Decoor Sandgrain
· L-ribbed, Wood-, Slate-, Silk-, Deco-, Sand- or Duragrain, Planar
· Double-skinned, PU-foamed door sections, Wood-, Slate-, Silk-, Deco-, Dura-
or Sandgrain, Planar exterior, Stucco-textured interior
· Door sections of equal height, horizontally ribbed or without ribbing, made
of hot-galvanized sheet steel
· Surface finish with high-quality coating on both sides (Decograin version
with high-quality plastic film coating on the outside)
· Without door handle set / inside locking
· We recommend fitting a garage door operator SupraMatic P.
· S-panelled Woodgrain
· Double-skinned, PU-foamed door sections, Woodgrain exterior, Stucco-textured interior · Hot-galvanized sheet steel door sections of equal height with panelling · Surface finish with high-quality coating on both sides · Without door handle set / inside locking · We recommend fitting a garage door operator SupraMatic P.
Sectional door ART 42 aluminium · Aluminium frame door section
· Glazed aluminium sectional door made of extruded aluminium tubular profiles
with polyester-primer coating on both sides
· Door sections of equal height in the standard version or with thermal break
· With uniform field division along the width · We recommend fitting a garage
door operator SupraMatic P.
Sectional door LTH 42
· S-ribbed, Nordic Pine · M-ribbed, Nordic Pine · L-ribbed, Nordic Pine ·
V-panelled, Nordic Pine
· Solid timber door sections, S- / M- / L-ribbed or V-panelled · Door sections of equal height · Optionally brushed surface finish (not possible for V-panelled version)
Sectional door LTH 42 with special styles
Nordic Pine
· Solid timber door sections with different styles · Door sections of equal height · Optionally brushed surface finish
See brochure material for additional details.
Technical manual: Sectional garage doors / 03.2024
3
Door type
Door leaf
Side doors with corner frame made of aluminium profiles
Standard sizes
· Appearance same as LTE 42 / 67 / ART 42, leaf frame made of extruded
aluminium profiles, depth 60 mm
· Door infill made of PU-foamed steel sections, Wood-, Slate-, Silk-, Deco-,
Dura- or Sandgrain, Planar exterior, Stucco-textured interior
· Surface with high-strength, high-quality coating (Decograin version with
high-quality plastic film coating on the outside)
Side doors with block frame made of aluminium profiles
Standard / special sizes
· Appearance same as LPU 42 / 67 / ART 42, door leaf frame and frame made of
extruded aluminium profiles (without thermal break), depth 60 mm, double door
seal on 3 sides
· Door infill made of PU-foamed steel sections, Wood-, Slate-, Silk-, Deco-,
Dura- or Sandgrain, Planar exterior, Stucco-textured interior
· Surface with high-strength, high-quality coating (Decograin version with
high-quality plastic film coating on the outside)
Hinged door with block frame made of aluminium profiles
· Appearance same as LPU 42 / 67, door leaf frame and frame made of extruded
aluminium profiles (without thermal break), depth 60 mm, double door seal on 3
sides
· Door infill made of PU-foamed steel sections, Wood-, Slate-, Silk-, Deco-,
Dura- or Sandgrain, Planar exterior, Stucco-textured interior
· Surface with high-strength, high-quality coating (Decograin version with
high-quality plastic film coating on the outside)
See brochure material for additional details.
4
Technical manual: Sectional garage doors / 03.2024
Sectional door LPU 42
Double-skinned steel sections S-ribbed Woodgrain
External views
The dimensions in the illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other sizes.)
Basic model
With aluminium frame NF / WF
With glazing type D
602
132
Size range
Door width in 1 mm increments, door height in grid height. Intermediate heights are possible up to LZ = 5500 mm. All grid heights also possible in special 125 mm S-ribbed version (to produce doors with matching appearance with different RM)
RM
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000 1900
4
6
2
3
A
B
C
F
6 500 125
2880 2920
6 475 119
2755 2800
5 550 138
2630 2655
5 520 130
2505 2535
5 500 125
2380 2420
5 475 119
2255 2300
4 562 141
4 550 138
4 531 133
4 520 130
4 500 125
4 475 119
8
10
12
No. of ventilation grilles with 40 cm2 ventilation cross section each
4
5
6
Number of infills per door section with glazing
6000
5750
5500
5250
5000
4750
4500
4250
4000
3750
3500
3250
3000
2750
2500
2375
2250
Doors with tension spring assembly
A
No. of door sections
B
Door section height
C Spacing
LZ
F
This range cannot be shortened (intermediate
heights)
RM Grid height
LZ Clear frame dimensions (from 2000)
Special equipment
Ventilation · Ventilation slots in bottom seal, ventilation cross section 65
cm2
for one metre door width · Ventilation grille, ventilation cross section 40
cm2 each · Aluminium frame with expanded mesh, 58% ventilation cross
section · Aluminium frame with stainless steel crimped mesh ,
mesh size 12 mm, ventilation cross-section 70% · Aluminium frame with
stainless steel welded grille (firefighting
infill), mesh size 100 mm, ventilation cross-section > 85%
· Aluminium frame with perforated stainless steel sheet, ventilation cross-
section 40%
· Folding roller bracket set / ventilation position (see page 55) (* only for
underground garage box doors)
Glazing options · Aluminium frame (standard profile NF or profile with thermal
break
WF) · Glazing type D, 16 mm
Technical manual: Sectional garage doors / 03.2024
5
Sectional door LPU 42
Double-skinned steel sections M-ribbed Wood-, Slate-, Deco-, Silk- or
Sandgrain
External views The dimensions in the illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other sizes.)
Basic model
With aluminium frame NF / WF
With glazing type D With panel glazing S0, S1, S2, Sunrise
With panel glazing M0
602
327
552
With panel glazing LD
936
202
202
202
132
Size range
Door width in 1 mm increments up to LZ = 5500 mm, door height in grid height. Intermediate heights are possible.
RM
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000 1900
3 2125 2 2240
4
6
8
10
2
3
4
5
4
5
6
7
8
3 2970
4 3690 5 4420 6 5140 7
2 3400
3 4490
4
A
B
C
6
500
250
6
475
237
5
550
275
5
520
260
5
500
250
5
475
237
4
562
281
4
550
275
4
531
265
4
520
260
4
500
250
4
475
237
12
No. of ventilation grilles with 40 cm2 ventilation cross section each
6
Number of glazings aluminium frame and type D
9 No. of glazings type S
8 No. of glazings type M
5 No. of glazings type L
6000
5750
5500
5250
5000
4750
4500
4250
4000
3750
3500
3250
3000
2750
2500
2375
2250
LZ
Doors with tension spring assembly (3000 × 2600 mm for Silkgrain)
A
No. of door sections
B
Door section height
C
Spacing
RM Grid height
LZ Clear frame dimensions (from 2000)
Up to width
Door size not possible for Silkgrain For Silkgrain on request
Special equipment
Ventilation · Ventilation slots in bottom seal, ventilation cross section 65
cm2
for one metre door width · Ventilation grille, ventilation cross section 40
cm2 each · Aluminium frame with expanded mesh, 58% ventilation cross
section · Aluminium frame with stainless steel crimped mesh ,
mesh size 12 mm, ventilation cross-section 70% · Aluminium frame with
stainless steel welded grille (firefighting
infill), mesh size 100 mm, ventilation cross-section > 85% · Aluminium frame
with perforated stainless steel sheet, ventilation
cross-section 40% · Folding roller bracket set / ventilation position (see
page 55)
(* only for underground garage box doors)
Glazing options · Aluminium frame (standard profile NF or profile with thermal
break
WF) · Glazing type D, 16 mm · Panel glazing type S, M or L, 22 mm
Design elements · Design inlay elements (see page 16)
6
Technical manual: Sectional garage doors / 03.2024
Sectional door LPU 42
Double-skinned steel sections L-ribbed All surface finishes
External views The dimensions in the illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other sizes.)
Basic model
With aluminium frame NF / WF
With glazing type D
With panel glazing S0, S1, S2, Sunrise
With panel glazing M0, M2
602
327
552
With panel glazing LD
936
202
202
5750
202
6000
132
Size range
Door width in the 1 mm grid, door height in grid height. Intermediate heights are possible up to LZ = 5500 mm in certain areas.
RM
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000 1900
3 2125 2 2240
4
6
8
10
2
3
4
5
4
5
3 2970
4 3690
2 3400
6
7
8
5 4420 6 5140 7
3 4490
4
A
B
6
500
6
475
5
550
5
520
5
500
5
475
4
562
4
550
4
531
4
520
4
500
4
475
12
No. of ventilation grilles with 40 cm2 ventilation cross section each
6
Number of glazings aluminium frame and type D
9 No. of glazings type S
8 No. of glazings type M
5 No. of glazings type L
5500
5250
5000
4750
4500
4250
4000
3750
3500
3250
3000
2750
2500
2375
2250
LZ
Doors with tension spring assembly (3000 × 2600 mm for Silkgrain)
A
No. of door sections
B
Door section height
RM Grid height
LZ Clear frame dimensions (from 2000)
Up to width
Door size not possible for Silkgrain For Silkgrain on request
Note: Duragrain only possible up to LZ 5500
Special equipment
Ventilation · Ventilation slots in bottom seal, ventilation cross section 65
cm2
for one metre door width · Ventilation grille, ventilation cross section 40
cm2 each · Aluminium frame with expanded mesh, 58% ventilation cross
section · Aluminium frame with stainless steel crimped mesh ,
mesh size 12 mm, ventilation cross-section 70% · Aluminium frame with
stainless steel welded grille (firefighting
infill), mesh size 100 mm, ventilation cross-section > 85% · Aluminium frame
with perforated stainless steel sheet, ventilation
cross-section 40% · Folding roller bracket set / ventilation position (see
page 55)
(* only for underground garage box doors)
Glazing options · Aluminium frame (standard profile NF or profile with thermal
break
WF) · Glazing type D, 16 mm · Panel glazing type S, M or L, 22 mm
Design elements · Styles and design glazings (see page 14)
Technical manual: Sectional garage doors / 03.2024
7
Sectional door LPU 42
Double-skinned steel sections D-ribbed Silkgrain
External views
The dimensions in the illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other sizes.)
D-ribbed basic model
D-ribbed with aluminium D-ribbed with glazing
frame NF / WF
type D
602
132
Size range
Door width in the 1 mm grid, door height in grid height. Intermediate heights are possible up to LZ = 5500 mm in certain areas.
RM
3000
2850
2750
2600 2500 2375 2250 2205 2125 2080 2000 1900
4
6
2
3
A
B
F (D-Sicke)
6
500
2895 2930 2755 2870
6
475
2750 2785
5
550
2645 2680 2505 2570
5
520
2490 2535
5
500
2395 2430
5
475
2255 2305
4
562
4
550
2130
4
531
4
520
2005 2010
4
500
4
475
1805 1880
8
10
12
No. of ventilation grilles with 40 cm2 ventilation cross section each
4
5
6 Number of glazings aluminium frame and type D
6000
5750
5500
5250
5000
4750
4500
4250
4000
3750
3500
3250
3000
2750
2500
2375
2250
LZ
Doors up to 3000 × 2600 mm with tension spring assembly
A
No. of door sections
B
Door section height
F
This range cannot be shortened (intermediate
heights)
RM Grid height
LZ Clear frame dimensions (from 2000)
Up to width
On request
Special equipment
Ventilation · Ventilation slots in bottom seal, ventilation cross section 65
cm2
for one metre door width · Ventilation grille, ventilation cross section 40
cm2 each · Aluminium frame with expanded mesh, 58% ventilation cross
section · Aluminium frame with stainless steel crimped mesh ,
mesh size 12 mm, ventilation cross-section 70% · Aluminium frame with
stainless steel welded grille (firefighting
infill), mesh size 100 mm, ventilation cross-section > 85% · Aluminium frame
with perforated stainless steel sheet, ventilation
cross-section 40% · Folding roller bracket set / ventilation position (see
page 55)
(* only for underground garage box doors)
Glazing options
· Aluminium frame (standard profile NF or profile with thermal break WF)
· Glazing type D, 16 mm Design elements
· Styles and design glazings (see page 14) · Design inlay elements (see page
16)
8
Technical manual: Sectional garage doors / 03.2024
Sectional door LPU 42
Double-skinned steel sections S-panelled Woodgrain
External views
The dimensions in the illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other sizes.)
Basic model
Style S0
Style S1 with decorative Style S2 with decorative Style S10
rail (diamond)
rail (cross)
Size range
Door width in the 1 mm grid, door height in grid height. Intermediate heights are possible up to LZ = 5500 mm in certain areas.
3000
2850
2750
2600
2500
2375
2250
2205
2125
2080
2000
1900
3 2125
4
5
6
7
A
B
E
6
500
2948 3000
6
475
2834 2875
5
550
2673 2750
5
520
2560 2625
5
500
2448 2500
5
475
2336 2375
4
562
2167 2250
4
550
2128 2205
4
531
2058 2125
4
520
2018 2080
4
500
1948 2000
4
475
1860 1875
8
Number of panels per door section
RM 2250 2375 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 5250 5500
LZ
Doors with tension spring assembly
A
No. of door sections
B
Door section height
E
This range can be shortened
(intermediate heights, shortening only possible
from top)
RM Grid height
LZ Clear frame dimensions (from 2000)
Up to width
Special equipment
Ventilation · Ventilation slots in bottom seal, ventilation cross section 65
cm2
for one metre door width · Folding roller bracket set / ventilation position
(see page 55)
Glazing options panel glazing Clear or crystal structure double panes, 16 mm · Styles S0, S1, S2 · Styles S10, S20, S30, S40, S50, S60 (see page 13)
Technical manual: Sectional garage doors / 03.2024
9
Sectional door ART 42 aluminium
Aluminium tubular profile door sections
External views The illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other sizes.) Basic model with aluminium frame NF / WF
Notes:
· The door leaf of the basic model (standard) consists of door sections of
equal height.
· The openings have different heights. · Identical openings are possible as a
special variant. · Only possible with garage door operator!
Size range
Door width in 1 mm increments, door height in grid height. Intermediate heights are not possible up to LZ 5500 .
3000 2850 2750 2600 2500
A
B
6
500
6
475
5
550
5
520
5
500
2375 2250 2205
5
475
4
562
4
550
2125 2080 2000 1900
4
531
4
520
4
500
4
475
2
3
4
5
Number of glazings per door section*
RM 2250 2375 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 5250 5500
LZ
Doors up to 3000 × 2600 mm with tension spring assembly
A
No. of door sections
B
Door section height
C
Spacing
RM Grid height
LZ Clear frame dimensions (from 2000)
- Additional rails possible after technical inspection Maximum field width: 1277 mm Minimum field width: 250 mm
Special equipment
Ventilation
· Perforated steel sheet made of stainless steel (LB), ventilation cross-
section = 40% (high-quality wet coating of infill not possible)
· Expanded mesh made of stainless steel (SE), ventilation crosssection = 58%
(high-quality wet coating of infill not possible)
· Crimped mesh, mesh size 12 mm, ventilation cross-section = 70% (high-quality
wet coating of infill not possible)
· Welded grille (firefighting infill), mesh size 100 mm, ventilation cross-
section > 85% (high-quality wet coating of infill not possible)
· Perforated steel sheet made of stainless steel, ventilation crosssection =
40% (high-quality wet coating of infill not possible)
· Folding roller bracket set / ventilation position (see page 55)
Notes:
· Door sizes do not apply for expanded mesh infill, crimped mesh, welded
grille and perforated sheet infill.
· Door sizes on request · Welded grille only for underground garage box doors
Glazing options
· Synthetic double pane, clear / clear (S2), 26 mm · Synthetic double pane,
crystal structure / crystal structure (U2),
26 mm · Synthetic double pane, grey tinted (A2), 26 mm · Synthetic double
pane, white tinted (opal) (M2), 26 mm · Polycarbonate double pane clear /
clear (C2), 26 mm · Double-moulded pane (S), 16 mm (only possible for NF)
10
Technical manual: Sectional garage doors / 03.2024
Sectional door ART 42 Vitraplan
Aluminium tubular profile door sections / outside and inside RAL 9005 Jet
black
External views
The illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other sizes.)
Basic model
Notes:
· The door leaf of the basic model (standard) consists of door sections of
equal height.
· The openings have different heights. · Only possible with garage door
operator! · Only possible with track application N or L · Not possible with
expanded, corrugated, welded
grill infills, PU infill or perforated sheet infill
Size range Door width in 1 mm increments, door height in grid height
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000 1900
A
B
6
500
6
475
5
550
5
520
5
500
5
475
4
562
4
550
4
531
4
520
4
500
4
475
RM 2250 2375 2500 2750 3000 3250 3500 3750 4000
LZ
A
No. of door sections
B
Door section height
RM Grid height
LZ Clear frame dimensions (from 2000)
Special equipment
Glazing options · Synthetic double pane, clear / clear (S2), 26 mm (standard)
· Synthetic double pane, crystal structure / crystal structure (U2),
26 mm · Synthetic double pane, grey tinted (A2), 26 mm · Polycarbonate double
pane clear / clear (C2), 26 mm
Technical manual: Sectional garage doors / 03.2024
11
202
202
Sectional door LPU 67 Thermo
Double-skinned steel sections with thermal break / depth 67 mm M- / L-ribbed
Silk- or Decograin
External views
The dimensions in the illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other sizes.)
Basic model
With aluminium frame *
With glazing type D With panel glazing S0, S1, S2, Sunrise
602
327
With panel glazing M0
552
With panel glazing LD
936
202
202
132
602
327
552
936
202
202
132
RM 2250 2375 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000
Size range
Door width in 5 mm increments up to LZ = 5000 mm, door height in grid height. Intermediate heights are possible.
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000 1900
3 2125 2 2240
2
3
4
5
3 2970
4 3690
2 3400
4
6
7
5 4420
3 4490
5 8
6 4
A
B
6
500
6
475
5
550
5
520
5
500
5
475
4
562
4
550
4
531
4
520
4
500
4
475
Number of glazings aluminium frame and type D
No. of glazings type S
No. of glazings type M
No. of glazings type L
LZ
Doors up to 3000 × 2500 mm with tension spring assembly (not possible with aluminium frames)
A
No. of door sections
B
Door section height
RM Grid height LZ Clear frame dimensions (from 2000)
Up to width
Door size not possible for Silkgrain
Door size for Silkgrain only possible with track application N or L
- Technical inspection required
12
Technical manual: Sectional garage doors / 03.2024
Sunrise glazing
for sectional doors LPU 42
External views
Sunrise glazing for sectional doors LPU 42 for standard and special sizes Glazing options for S-panelled type (not possible for doors with 3 panels for each section)
Style S10
Style S20
425
300
2130 LZ 2750 Style S30
2751 LZ 3500 Style S40
3501 LZ 4000 Style S50
4001 LZ 4750 Style S60
4751 LZ 5500
4751 LZ 5500
Technical manual: Sectional garage doors / 03.2024
13
design element
for sectional doors 1) and side doors LPU 67 Silk- and Decograin LPU 42 all
surface finishes
Door view Style arrangements (exterior views correspond to door size 2500 ×
2125 mm). Style sideroom 200 mm up to LZ = 3000 mm and 400 mm from LZ = 3001
mm (can be combined with design inlays)
Example: Style 451 arrangement
Style 450 with stainless steel plinth profile, with square perforation (2-part
over 3000 mm width)
Style 453, stainless steel frame with infill with small square Style 463,
stainless steel frame with infill with small square and synthetic double pane
2)
Style 456, small stainless steel square (with style 450 optional plinth
profile bottom section only with 2 squares)
Style 471, stainless steel frame Style 481, stainless steel frame and
synthetic double pane 2) or triple insulated glass pane
Style 474*, large stainless steel square
Style 451, stainless steel frame Style 461, stainless steel frame and
synthetic double pane 2) or triple insulated glass pane
Style 454, large stainless steel square
Style 452, stainless steel frame with infill Style 462, stainless steel frame
with infill and synthetic double pane 2)
Style 455*, large and small stainless steel square
Style 459, with stainless steel ring Style 469, with stainless steel ring and synthetic double pane 2)
Style 460*, stainless steel 150 × 150 mm
Style 472, stainless steel frame with infill Style 482, stainless steel frame with infill and synthetic double pane 2)
Style 473, stainless steel frame with infill with small square Style 483, stainless steel frame with infill with small square and synthetic double pane 2)
Style 475*, large and small stainless steel square
Style 451, 452, 454, 456, 459, 461, 462, 469, 471 and 481 optionally with stainless steel plinth profile as in style 450 (only on door heights RM 2125 mm and 2250 mm) * Style not available for LPU 67
Style 457, curved stainless steel frames
Style 458, stainless steel hole arc
- Except for doors with wicket door 2) LPU 42 glazing with synthetic double
panes clear (DS) or crystal structure (DK) or triple insulated glass pane,
clear view 160 × 160 mm, pane thickness 41 mm,
LPU 67 synthetic triple pane clear (S3) or crystal structure (U3), clear view 160 × 160 mm, pane thickness 66 mm
14
Technical manual: Sectional garage doors / 03.2024
design element
for sectional doors and side doors LPU 42 all surface finishes
Side door view
Style arrangements (exterior views correspond with the door size 1000 × 2125 mm. Other door sizes may have a different design)
Style 450
Style 451, 461 1)
Style 452, 462 1)
Style 453, 463 1)
Style 454
Style 455
Style 456
Style 457
Style 458
Style 459, 469 1)
Style 460
Style 471, 481 1)
Style 472, 482 1)
Style 473, 483 1)
Style 474
Style 475
Styles 451, 452, 454, 456, 459, 461, 462, 469, 471 and 481 optional with stainless steel plinth profile as in style 450 (only on door in door heights RM 2125 and 2250 mm)
Numbers and words
· 2 fonts “Classic” & “Modern” · Positive view: The cut-out numbers or letters
are applied to the
door with this variant. Numbers and individual letters 4 characters per
section Height of characters 80 mm and 150 mm S-, M-, L- and D-ribbed,
free horizontal positioning (X-axis) · Negative view: With this variant, the
letters are cut out of the sheet and the sheet is applied to the door.
“Classic” font
Positive view
Street names and words Height of characters 80 mm, total height of sheet
150 mm M-, L- and D-ribbed
Size 80 mm / size 150 mm
Negative view (on request)
Size 80 mm
“Modern” font Positive view
Negative view (on request)
Size 80 mm / size 150 mm
Size 80 mm
- LPU 42 glazing with synthetic double panes clear (DS) or crystal structure (DK) or triple insulated glass pane, clear view 160 × 160 mm, pane thickness 41 mm, LPU 67 synthetic triple pane clear (S3) or crystal structure (U3), clear view 160 × 160 mm, pane thickness 66 mm
Technical manual: Sectional garage doors / 03.2024
15
design element
for sectional doors LPU 42, D- and M-ribbed
View of design inlay elements (can be combined with styles) Style arrangements (other arrangements on request)
Sectional door view 2500 × 2125
Sectional door view 5000 × 2125
Side door view 1000 × 2125
Style 450 With stainless steel plinth profile with / without square perforation Ordering width: Up to 3000 mm 1-part Over 3000 mm 2-part
Style 501 With continuous inlays in stainless steel / timber look or RAL to choose
Style 500 With divided inlays (2 × 435 mm) in stainless steel look / timber look or RAL to choose
Style 502
Door with 4 sections 5 sections 6 sections
No. 1 30 % 15 % 8 %
No. 2 50 % 30 % 15 %
Inlay lengths
Section
No. 3
No. 4
73 %
100 %
50 %
73 %
30 %
50 %
Available in stainless steel/timber look or RAL to choose
No. 5
100 % 73 %
No. 6
100 %
Style 503
LZ 2000 > 2000
Inlay lengths 800 1000
Available in stainless steel/timber look or RAL to choose
16
Technical manual: Sectional garage doors / 03.2024
Sectional door LPU 42 with wicket door without threshold rail
S-, M-, L-, D-ribbed
External views
The dimensions in the illustrations correspond to door height 2125 mm.
Deviations may occur with other heights. Due to the low threshold height, the
ground in front of the garage must be level or sloped to guarantee smooth
opening of the wicket door (opening outwards) see page 58. A rain canopy is
provided above the wicket door for doors with wicket door with more than 4
door sections see page 54.
Basic model
With aluminium frame With aluminium frame
NF / WF
NF / WF
With glazing type D
With glazing type D
DHS OK ST = DHS + 30
830/1140 2000
Basic model
830/1140 2000
830/1140 3000
With aluminium frame With aluminium frame
NF / WF
NF / WF
830/1140 2000
With glazing type D
830/1140 3000
With glazing type D
DHS OK ST = DHS + 30
830/1140 2000
830/1140 2000
830/1140 3000
830/1140 2000
830/1140 3000
Wicket doors
The wicket doors are always in four parts and, in the S-ribbed version, always with even spacing of the ribs. The clear passage width of the wicket door is 830 / 1140 mm and the threshold height starts at 5 mm and increases to 10 mm. Beyond their standard arrangements, wicket doors without glazing can be offset to a fixed edge distance of 500 mm.
Special equipment
Ventilation with S- / M- / L- / D- / T-ribbing
(based on technical feasibility) · Ventilation grille, ventilation cross
section 40 cm2 for each
arrangement
2500
2505 3500
3505 4000
· Aluminium frame with expanded mesh, 58% ventilation cross section
Glazing options
· Aluminium frame (standard profile NF or profile with thermal break WF)
· Glazing type D, 16 mm
· Panel glazing type S or M, 22 mm
· With wicket doors with multiple-point locking, glazings are only possible
above the wicket door (from the 5th section from the bottom)
· With integrated overhead door closer, glazing type S, M, NF and WF not
possible in the 4th wicket door section, only to the right and left of the
wicket door (except for wicket door arrangement “a” & “b”, here only on
request)
· Glazing in the 1st and 2nd section on request
· Design glazings (based on technical feasibility)
Design elements for doors with wicket door
Arrangement and number of elements as well as elements in the wicket door based on technical feasibility The dimensions in the illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other sizes)
Style 451, 461
Style 452, 462
Style 453, 463
Style 454
Style 455
Style 471, 481
Style 459, 469
Style 474
Style 475
Style 457 1)
Style 458 1)
Style 500 1)
Style 504 2)
Style 505 1)
- Only possible on left and / or right next to the wicket door! 2) Only possible in the wicket door!
Technical manual: Sectional garage doors / 03.2024
17
Sectional door LPU 42 with wicket door without threshold rail
S-, M-, L-, D-ribbed
RM 2375 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000
Size range
Door width in 1 mm grid, door height in grid height. Intermediate heights
possible from 5 door sections. See track applications for the ceiling height
and clear passage (pages 40 42, 47). Please observe the size ranges of the
door types.
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000 1900
3
5
A
B
C
D
DRH
6
500
1955
1955
831
6
475
1855
1855
793
5
550
2155
2155
906
5
520
2035
2035
861
5
500
1955
1955
831
5
475
1855
1855
793
4
562
2123
2203
924
4
550
2075
2155
906
4
531
1999
2079
877
4
520
1955
2035
861
4
500
1875
1955
831
4
475
1775
1775
793
7
9
No. of ventilation grilles with 40 cm2 ventilation cross section each
3
4
5
Number of infills in aluminium frame per door section
1
1 2370
3 3
4
5
No. of type D, M glazings per door section
4
5
No. of type S glazings per door section
LZ
A B C D
DRH RM LZ OK ST
Doors up to 2500 × 2250 mm with tension spring assembly No. of door sections Door section height Clear passage height of wicket door (DHS) Clear passage height of wicket door (DHS) with top glazing type D, S, M, stainless steel styles (not for design elements “Numbers & words”) Lever height Grid height Clear frame dimensions (from 2000) Top edge of wicket door = DHS + 30 mm Up to width
Notes:
· Only track application N or L is possible for sectional doors with wicket
door!
· For doors up to RM 2250 and with top glazing type D, S, M, the distance from
FFL to the bottom edge of the lintel must be equal to or greater than the
ordering size (RM).
· For linkage fitting for multiple-point locking in doors with wicket door
with 4 sections, a clearance of 500 mm is required outside above the door (see
page 39).
Clear passage width with (LDB) with 90° leaf opening and optional push bar
90° LDB 140
18
Technical manual: Sectional garage doors / 03.2024
Sectional door LPU 42 with wicket door without threshold rail
S-, M-, L-, D-ribbed
External views (matching for doors with glazing)
LDB = 830/1140
INSIDE
Glazing type D
602
2000 LZ 3500
LDB = 830/1140
Glazing type D
4001 LZ 4500
INSIDE
132
Glazing type S
327
Glazing type S
202
Glazing type M
552
Glazing type M
202
Aluminium frame NF / WF
Aluminium frame NF / WF
120
120
The dimensions in the illustrations correspond to door height 2125 mm and arrangement 3.
Technical manual: Sectional garage doors / 03.2024
19
Sectional door LPU 42 with wicket door without threshold rail
S-panelled Woodgrain
External views
The dimensions in the illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other door sizes! Due to the low threshold height, the ground in front of the garage must be level or sloped to guarantee smooth opening of the wicket door (opening outwards) see page 58. A rain canopy is provided above the wicket door on doors with wicket door with more than 4 door sections (see page 54).
Basic model
Style S0
Style S1 with decorative Style S2 with decorative
rail (diamond)
rail (cross)
DHS OK ST = DHS + 30
765
Wicket doors
The wicket doors are always in four parts. The clear passage width of the
wicket door is 765 mm and the threshold height starts at 5 mm and increases to
10 mm.
Size range
Door width in 1 mm increments, door height in grid height. Intermediate
heights are not possible. See track applications for the ceiling height and
clear passage (pages 40 42, 47).
RM 2500 2750 3000 3250 3500 3750 4000
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000
3
4 LZ
A
B
C
DrH
6
500
1955
831
6
475
1855
793
5
550
2155
906
5
520
2035
861
5
500
1955
831
5
475
1855
793
4
562
2203
924
4
550
2155
906
4
531
2079
877
4
520
2035
861
4
500
1955
831
5
Numbers of panels or panel glazings per door section
A B C DrH RM LZ OK ST
No. of door sections Door section height Clear passage height of wicket door (DHS) Lever height Grid height Clear frame dimension (from 2000 mm) Top edge of wicket door = DHS + 30 mm Up to width
Notes:
· With 4 panels, the wicket door is set offcentre!
· Sectional door with wicket door only possible with track application N or L!
· For doors up to 2250 mm, the distance from FFL to the bottom edge of the
lintel must be equal to or greater than the ordering size (RM).
· For linkage fitting for multiple-point locking in doors with wicket door
with 4 sections, a clearance of 500 mm is required outside above the door (see
page 39).
· Not possible as a wicket door with LDB = 1140.
Special equipment
Glazing options panel glazing Clear or crystal structure double panes, 16 mm
· Glazing S0 · Glazing S1 · Glazing S2 · Glazing S10, S20 (see page 13) · With
wicket doors with multiple-point locking, glazings are only
possible above the wicket door (from the 5th section from the bottom)
· With integrated overhead door closer, glazing type S not possible in the 4th
wicket door section (only left and right next to the wicket door)
· Glazing in the 1st and 2nd section on request
20
Technical manual: Sectional garage doors / 03.2024
Sectional door LPU 42 with wicket door without threshold rail
Arrangement of the wicket door
Wicket door LDB = 830
A
a
b
INSIDE
B
a
b
INSIDE
C
Notes:
· Arrangement “a” and “b” only for S-, M and L-ribbed versions (glazing
possible on request), fixed distance 500 mm, RC2 not possible for arrangement
“a” and “b”
· Wicket door only opening outwards
· Track application Z only possible with arrangement “1”
INSIDE D
Sectional door, S-, M- or L-ribbed Sectional door, D-ribbed Sectional door
S-panelled Wicket door LDB = 1140
A
B
INSIDE
A 2000 3500 2000 3500 2000 2500
B 3501 4000 3501 4000 2501 3250
C 4001 4500 4001 4500
D 4501 5000 4501 5000 3251 4000
Notes: · Wicket door only opening outwards · Track application Z not possible
C
D
Sectional door, S-, M- or L-ribbed Sectional door, D-ribbed
A 2000 3500 2000 3500
B 3501 4000 3501 4000
C 4001 4500 4001 4500
D 4501 5000 4501 5000
Technical manual: Sectional garage doors / 03.2024
21
Sectional door LPU 42 with wicket door and high threshold rail
Double-skinned steel sections, S- / M- / L- / D-ribbed
External views
The dimensions in the illustrations correspond to door height 2125 mm. Deviations may occur with other heights. Due to the low threshold height, the ground in front of the garage must be level or sloped to guarantee smooth opening of the wicket door (opening outwards) see page 58. A rain canopy is provided above the wicket door on doors with wicket door with more than 4 door sections (see page 54).
Basic model
With aluminium frame With aluminium frame
NF / WF
NF / WF
With glazing type D
With glazing type D
830 2250
Basic model
830 2250
With aluminium frame With aluminium frame
NF / WF
NF / WF
830 2250
With glazing type D
With glazing type D
830 2000
830 2000
830 2000
Wicket doors
The wicket doors are always in four parts and, in the S-ribbed version, always
with even spacing of the ribs. The clear passage width of the wicket door is
830 mm, the threshold height is 85 mm (distance from top edge of wicket door
to FFL is 80 mm (see page 59).
Special equipment
Glazing options · Aluminium frame (standard profile NF or profile with thermal
break
WF) · Glazing type D, 16 mm · Panel glazing type S or M, 22 mm · Glazing in
the 1st and 2nd section on request
· Glazing possible from the 3rd wicket door section panel and above the wicket
door (from 3rd section from the bottom)
· Design glazings (see page 17) · Design elements (see page 17)
Styles Design inlay elements
Arrangement of the wicket door Threshold height 85 mm
2000 – 3500
Clear passage width with (LDB) with 90° leaf opening and optional push bar
90°
3501 – 4000 INSIDE
LDB 140
22
Technical manual: Sectional garage doors / 03.2024
Sectional door LPU 42 with wicket door and high threshold rail
Double-skinned steel sections, S- / M- / L- / D-ribbed
RM 2375 2500 2750 3000 3250 3500 3750 4000
Size range
Door width in 1 mm grid, door height in grid height. Intermediate heights
possible from 5 door sections. See track applications for the ceiling height
and clear passage (pages 40 42, 47). Please observe the size ranges of the
door types.
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000 1900
Threshold height 85 mm
A
B
C
D
DrH
6
500
1880
1880
831
6
475
1780
1780
793
5
550
2080
2080
906
5
520
1960
1960
861
5
500
1880
1880
831
5
475
1780
1780
793
4
562
2048
2128
924
4
550
2000
2080
906
4
531
1924
2004
877
4
520
1880
1960
861
4
500
1800
1880
831
4
475
1700
1780
793
3
5
7
No. of ventilation grilles with 40 cm2 ventilation cross section each
3
4
No. of infills in aluminium frame per door section
1
1 2370
3 3
4
No. of type D, M glazings per door section
4
No. of type S glazings per door section
LZ
A B C D
DRH RM LZ OK ST
Doors up to 3000 × 2250 mm with tension spring assembly No. of door sections Door section height Clear passage height of wicket door (DHS) Clear passage height of wicket door (DHS) with top glazing type D, M, S, stainless steel styles (not for design elements “Numbers & words”) Lever height Grid height Clear frame dimensions (from 2250 mm) Top edge of wicket door = DHS + 30 mm Up to width
Notes:
· Multiple-point locking for wicket doors not possible. · Only centre wicket
door position possible. · Not possible as a wicket door with LDB = 1140. · Not
possible with break-in-resistant track application RC 2!
Technical manual: Sectional garage doors / 03.2024
23
Sectional door LPU 42 with wicket door and threshold rail
Double-skinned steel sections, S-panelled Woodgrain
External views
The dimensions in the illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other door sizes! Due to the low threshold height, the ground in front of the garage must be level or sloped to guarantee smooth opening of the wicket door (opening outwards) see page 58. A rain canopy is provided above the wicket door on doors with wicket door with more than 4 door sections (see page 54).
Basic model
Style S0
Style S1 with decorative Style S2 with decorative
rail (diamond)
rail (cross)
DHS OK ST = DHS + 30
765
Wicket doors
The wicket doors are always in four parts. The clear passage width of the
wicket door is 765 mm, the threshold height is 85 mm (distance from top edge
of wicket door to FFL is 80 mm).
Size range
Door width in 1 mm increments, door height in grid height. Intermediate
heights are not possible. See track applications for the ceiling height and
clear passage (pages 40 42). Please observe the size ranges of the door
types.
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000
3
A
B
C
6
500
1880
6
475
1780
5
550
2080
5
520
1960
5
500
1880
5
475
1780
4
562
2130
4
550
2080
4
531
2005
4
520
1960
4
500
1880
4 Numbers of panels or panel glazings per door section
DrH
A
No. of door sections
831
B
Door section height
793
C
Clear passage height of wicket door (DHS)
906
DRH Lever height
861
RM
Grid height
831
LZ
Clear frame dimension (from 2250 mm)
793
OK ST Top edge of wicket door = DHS + 30 mm
924
Up to width
906
877
Notes: · Multiple-point locking for wicket doors not
861
possible.
831
· Only centre wicket door position possible.
· Not possible as a wicket door with LDB = 1140.
· Not possible with break-in-resistant track application RC 2!
RM 2375 2500
LZ
Special equipment
Glazing options panel glazing Clear or crystal structure double panes, 16 mm
· Glazing S0 · Glazing S1 · Glazing S2 · Glazing S10, S20 (see page 13) ·
Glazing possible from the 3rd wicket door section panel and above the wicket
door
(from 3rd section from the bottom) · Glazing in the 1st and 2nd section on
request · Glazing only possible with track application N and L!
Arrangement of the wicket door 2250 – 2500
24
Technical manual: Sectional garage doors / 03.2024
Sectional door LTH 42
S- / M- / L-ribbed, V-panelled Nordic Pine
External views
The dimensions in the illustrations correspond to size 2500 × 2125 mm. Deviations may occur with other sizes.)
Basic model, S-ribbed
Basic model, M-ribbed Basic model, L-ribbed
Basic model with V-panelled
RM 2250 2375 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000
Size range Door width in 5 mm increments, intermediate heights are possible.
3000 2875 2750 2625 2500 2375 2250 2205 2125 2080 2000 1955 1875
3
4
5
LZ
S-, M-, L-ribbed
V-panelling
A
B
C1 C2 C3
A
6 500 125 250
6
6 479 120 239
6
6 458 115 229
6
5 525 131 262
5
5 500 125 250
5
5 475 119 237
5
5 450 111 281 225
5
5 441 111 275 221
4 531 133 265
4
4 520 130 260
4 500 125 250
4
4 488 122 234
4 468 117 234
4
6 Numbers of panels or panel glazings per door section
Note: Sectional door LTH 42 only with torsion spring assembly
A
No. of door sections
B
Door section height
C1 S-ribbed spacing
C2 M-ribbed spacing C3 L-ribbed spacing RM Grid height
LZ Clear frame dimension (from 2000 mm)
Ventilation
· Ventilation slots in bottom seal (standard), ventilation cross section 65
cm2 for one metre door width
Glazing options (for panelled versions only) · Panel glazing with clear or crystal structure, 3 mm
Technical manual: Sectional garage doors / 03.2024
25
Sectional door LTH 42 with special styles
Nordic Pine
External views Style 401
Style 402
Style 405
Style 401
Style 402
Style 405
The dimensions in the illustrations correspond to the size 2500 × 2125 mm (top
row) as well as the size 5000 × 2125 mm (centre and bottom row). Deviations
may occur with other door sizes!
Size range
Door width in 5 mm increments, intermediate heights on request, further styles on request
3000 2875 2750 2625 2500 2375 2250 2205 2125 2080 2000 1955 1875
A
B
6
500
6
479
6
458
5
525
5
500
5
475
5
450
5
441
4
531
4
520
4
500
4
488
4
468
RM 2375 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000
Note:
Sectional door LTH 42 only with
LZ
torsion spring assembly
A
No. of door sections
B
Door section height
RM Grid height
LZ Clear frame dimension (from 2250 mm)
Ventilation
Ventilation slots in bottom seal (standard), ventilation cross section 65 cm2 for one metre door width
26
Technical manual: Sectional garage doors / 03.2024
Track application Z
Z = Tension spring track application
INSIDE
LZ
90 (105**)
INSIDE GIM LZ + 180
(105**) 90
Note:
** Clearance required for fitting doors with leading photocell (see page 55).
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600
Manual operation
Min. DE
LDH
RM + 100
RM 80
2000
1820
2100
1920
2180
2000
2225
2045
2305
2125
2350
2170
2475
2295
2600
2420
2700
2520
With operator
Min. DE
LDH
RM + 115
RM 30
2015
1870
2115
1970
2195
2050
2240
2095
2320
2175
2365
2220
2490
2345
2615
2470
2715
2570
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 695 Max. DE with track suspension set I = 1456 = RM + 1423 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· The clearance for fitting and subsequent operation of the door must be
complied with.
· Increased required headroom for folding roller bracket set (see page 55).
· No additional required headroom for ThermoFrame sets 4 5.
ProMatic, SupraMatic E, P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 2600 With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
155 125
Technical manual: Sectional garage doors / 03.2024
27
Track application Z
Version with RC 2
165 125 RM 80
Z = Tension spring track application
165
INSIDE
90
LZ
90
205
INSIDE GIM LZ + 180
205
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600
Min. DE RM + 115
2015 2115 2195 2240 2320 2365 2490 2615 2715
With operator
LDH RM – 30
1870 1970 2050 2095 2175 2220 2345 2470 2570
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 695 Max. DE with track suspension set I = 1456 = RM + 1423 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· The clearance for fitting and subsequent operation of the door must be
complied with.
· Increased required headroom for folding roller bracket set (see page 55).
· No additional required headroom for ThermoFrame sets 4 5.
· LPU 67 Thermo not possible with operator ProMatic. · LPU 67 Thermo not
possible with aluminium frames · Only possible with garage door operator!
ProMatic, SupraMatic E, P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 2600 With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
28
Technical manual: Sectional garage doors / 03.2024
Track application Z
Version with LPU 67
190 125 RM 105
Z = Tension spring track application
190
INSIDE
90
LZ
90
205
INSIDE GIM LZ + 180
205
RM
1900 2000 2080 2125 2205 2250 2375 2500
Min. DE
RM +115 2015 2115 2195 2240 2320 2365 2490 2615
With operator
LDH
RM 55 1845 1945 2025 2070 2150 2195 2320 2445
Min. DE with ThermoFrame set
6, 7, 8, 9 RM +145
2045 2145 2225 2270 2350 2395 2520 2645
LDH RM LZ DE
ET GIM V1 W
g ¡¢£ ¤¢¥¥¢¦¡ §¡¨¦§©
q£¨ §¡¨¦§©
g ¡¢£ £¢¡ ¨¡¥¨
g¡¨ ¨¦ §¡¨¦§©
w¢ h standar suspension = w C 410
= 695 w¢ h ¨©§ ©£¢ ¥!¥¤¡¥¨ ¥¡© w C
= 1456 = 1423 w¢ h ¨©§ ©£¢ ¥!¥¤¡¥¨ ¥¡© s
w C
h¨¥©¢¡ “¢
s©¡£¨£ ¦¢£¢¦¡ ¨¡¥¨
¡¢£ ¤¡£¢©£ ” ¥!¥¤¡¥¨
T©¢ ¨¥©¢¡ “¢ ¨ !¨¦ ¤¡£¢©£ §¡¢
Notes:
· The clearance for fitting and subsequent operation of the door must be
complied with.
· Increased required headroom for folding roller bracket set (see page 55).
· LPU 67 Thermo not possible with operator ProMatic. · LPU 67 Thermo not
possible with aluminium frames · Only possible with garage door operator!
ProMatic, SupraMatic E, P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 2500 With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
Technical manual: Sectional garage doors / 03.2024
29
Track application N
N = Normal track application INSIDE
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
Manual operation
Min. DE
LDH
RM +210
RM 50
2110
1850
2210
1950
2290
2030
2335
2075
2415
2155
2460
2200
2585
2325
2710
2450
2810
2550
2960
2700
3060
2800
3210
2950
With operator
Min. DE *
LDH
RM +210
RM
2110
1900
2210
2000
2290
2080
2335
2125
2415
2205
2460
2250
2585
2375
2710
2500
2810
2600
2960
2750
3060
2850
3210
3000
LZ
90 (105**)
INSIDE GIM LZ + 180
(105**) 90
Note: * For doors under thermal loads, you should place the operator 40 mm
higher if required (RM + 210 + 40).
** Clearance required for fitting doors with leading photocell (see page 55).
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 520 Max. DE with track suspension set = RM
- 805 Max. DE with track suspension set I = 1456 = RM + 1533 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· The clearance for fitting and subsequent operation of the door must be
complied with.
· Increased required headroom for folding roller bracket set (see page 55).
· No additional required headroom for ThermoFrame sets 4 5.
ProMatic, SupraMatic E, P and HT
LPU 42 LPU 67
With short boom (K) up to door height 2250
2250 2125
With medium boom (M) up to door height 2500 2500 2375
With long boom (L) up to door height 3000
3000 3000
With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
155 125
30
Technical manual: Sectional garage doors / 03.2024
Track application N
Version with RC2, door leaf > 170 kg, LZ > 5000
165 125 RM + 30
N = Normal track application 165 INSIDE
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
Manual operation
Min. DE
LDH
RM +210
RM 50
2110
1850
2210
1950
2290
2030
2335
2075
2415
2155
2460
2200
2585
2325
2710
2450
2810
2550
2960
2700
3060
2800
3210
2950
With operator
Min. DE *
LDH
RM +210
RM
2110
1900
2210
2000
2290
2080
2335
2125
2415
2205
2460
2250
2585
2375
2710
2500
2810
2600
2960
2750
3060
2850
3210
3000
90
LZ
90
205
INSIDE GIM LZ + 180
205
Note:
- For doors under thermal loads, you should place the operator 40 mm higher if required (RM + 210 + 40).
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 520 Max. DE with track suspension set = RM
- 805 Max. DE with track suspension set I = 1456 = RM + 1533 ET Distance back
GIM Interior garage dimension V1 Rear operator boom suspension W Total
distance back including operator head
Notes: · The clearance for fitting and subsequent operation of the
door must be complied with. · Increased required headroom for folding roller bracket set
(see page 55). · No additional required headroom for ThermoFrame sets
4 5. · LPU 67 Thermo not possible with operator ProMatic. · RC 2 only possible with garage door operator!
ProMatic, SupraMatic E, P and HT With short boom (K) up to door height 2250 With medium boom (M) up to door height 2500 With long boom (L) up to door height 3000 With special boom length on request
LPU 42 2250 2500 3000
V1 2775 3025 3700
W 3200 3450 4125
Technical manual: Sectional garage doors / 03.2024
31
Track application N
Version with LPU 67
190 125 RM + 5
N = Normal track application 190 INSIDE
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
Min. DE *
RM +210 2110 2210 2290 2335 2415 2460 2585 2710 2810 2960 3060 3210
With operator Min. DE with
ThermoFrame set 6, 7, 8, 9 RM +255 2155 2255 2335 2380 2460 2505 2630 2755
2855 3005 3105 3255
LDH
RM 1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
90
LZ
90
205
INSIDE GIM LZ + 180
205
Note:
- For doors under thermal loads, you should place the operator 40 mm higher if required (RM + 210 + 40).
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 520 Max. DE with track suspension set = RM
- 805 Max. DE with track suspension set I = 1456 = RM + 1533 ET Distance back
GIM Interior garage dimension V1 Rear operator boom suspension W Total
distance back including operator head
Notes: · The clearance for fitting and subsequent operation of the
door must be complied with. · Increased required headroom for folding roller bracket set
(see page 55). · No additional required headroom for ThermoFrame sets
4 5. · LPU 67 Thermo not possible with operator ProMatic. · Only possible with garage door operator!
ProMatic, SupraMatic E, P and HT With short boom (K) up to door height 2250 With medium boom (M) up to door height 2500 With long boom (L) up to door height 3000 With special boom length on request
LPU 67 2125 2375 3000
V1 2775 3025 3700
W 3200 3450 4125
32
Technical manual: Sectional garage doors / 03.2024
Track application L
L = low headroom track application INSIDE
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
Manual operation
Min. DE
LDH
RM +100 2000 2100 2180 2225 2305 2350 2475 2600 2700 2850 2950 3100
RM 100 1800 1900 1980 2025 2105 2150 2275 2400 2500 2650 2750 2900
Min. DE *
RM +115 2015 2115 2195 2240 2320 2365 2490 2615 2715 2865 2965 3115
With operator
LPU 42
LDH Up to LZ = 3000 mm
LDH From LZ = 3010 mm
RM 30
RM 80
1870
1820
1970
1920
2050
2000
2095
2045
2175
2125
2220
2170
2345
2295
2470
2420
2570
2520
2720
2670
2820
2770
2970
2920
LZ
90 (105**)
INSIDE GIM LZ + 180
(105**) 90
Note: * For doors under thermal loads, you should place the operator 40 mm
higher if required (RM + 115 + 40).
** Clearance required for fitting doors with leading photocell (see page 55).
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 695 Max. DE with track suspension set I = 1456 = RM + 1423 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· The clearance for fitting and subsequent operation of the door must be
complied with.
· Increased required headroom for folding roller bracket set (see page 55).
· For DE > RM + 285 an additional 120 × 60 tubular profile is required to
strengthen the suspension construction in the area of the torsion springs.
· No additional required headroom for ThermoFrame sets 4 5.
ProMatic, SupraMatic E, P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 3000 With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
155 125
Technical manual: Sectional garage doors / 03.2024
33
Track application L
Version with RC 2, door leaf > 170 kg, LZ > 5000
165 125 RM 80
L = low headroom track application
165
INSIDE
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
Manual operation
Min. DE
LDH
RM +100 2000 2100 2180 2225 2305 2350 2475 2600 2700 2850 2950 3100
RM 100 1800 1900 1980 2025 2105 2150 2275 2400 2500 2650 2750 2900
Min. DE *
RM +115 2015 2115 2195 2240 2320 2365 2490 2615 2715 2865 2965 3115
With operator
LPU 42
LDH Up to LZ = 3000 mm
LDH From LZ = 3010 mm
RM 30
RM 80
1870
1820
1970
1920
2050
2000
2095
2045
2175
2125
2220
2170
2345
2295
2470
2420
2570
2520
2720
2670
2820
2770
2970
2920
90
LZ
90
205
INSIDE GIM LZ + 180
205
Note:
- For doors under thermal loads, you should place the operator 40 mm higher if required (RM 2 + 115 + 40).
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 695 Max. DE with track suspension set I = 1456 = RM + 1423 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· The clearance for fitting and subsequent operation of the door must be
complied with.
· Increased required headroom for folding roller bracket set (see page 55).
· For DE > RM + 285 an additional 120 × 60 tubular profile is required to
strengthen the suspension construction in the area of the torsion springs.
· No additional required headroom for ThermoFrame sets 4 5.
· RC 2 only possible with garage door operator!
ProMatic, SupraMatic E, P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 3000 With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
34
Technical manual: Sectional garage doors / 03.2024
Track application L
Version with LPU 67
190 125 RM 105
L = low headroom track application
190
INSIDE
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
Min. DE *
RM +115 2015 2115 2195 2240 2320 2365 2490 2615 2715 2865 2965 3115
With operator
Min. DE with ThermoFrame
set 6, 7, 8, 9
LDH Up to LZ = 3000 mm
RM +145
RM 55
2045
1845
2145
1945
2225
2025
2270
2070
2350
2150
2395
2195
2520
2320
2645
2445
2745
2545
2895
2695
2995
2795
3145
2945
LDH From LZ = 3010 mm
RM 105 1795 1895 1975 2020 2100 2145 2270 2395 2495 2645 2745 2895
90
LZ
90
205
INSIDE GIM LZ + 180
205
Note:
- For doors under thermal loads, you should place the operator 40 mm higher if required (RM + 115 + 40).
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 695 Max. DE with track suspension set I = 1456 = RM + 1423 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· The clearance for fitting and subsequent operation of the door must be
complied with.
· Increased required headroom for folding roller bracket set (see page 55).
· For DE > RM + 285 an additional 120 × 60 tubular profile is required to
strengthen the suspension construction in the area of the torsion springs.
· No additional required headroom for ThermoFrame sets 4 5.
· LPU 67 Thermo not possible with operator ProMatic. · Only possible with
garage door operator!
ProMatic, SupraMatic E, P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 3000 With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
Technical manual: Sectional garage doors / 03.2024
35
Track applications H
H = High-lift track application
INSIDE
(105**)
(105**)
INSIDE
Note: * with ThermoFrame 255 ** Clearance required for fitting doors with
leading photocell (see
page 55).
Version without wicket door
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
Track height
(1) with spring buffer
(2) with buffer stop
min.
Max.
min.
Max.
2285
2659
2660
3215
2385
2759
2760
3315
2465
2839
2840
3395
2510
2884
2885
3440
2590
2964
2965
3520
2635
3009
3010
3565
2760
3134
3135
3690
2885
3259
3260
3815
2985
3359
3360
3915
3135
3509
3510
4065
3290
3609
3610
4165
3565
3759
3760
4315
LDH Clear passage height RM Grid height LF Structural opening LH Track height
LZ Clear frame dimension DE Ceiling height
Max. DE standard suspension = LH + 450 Max. DE with track suspension set = LH
- 725 Max. DE with track suspension set I = 1499 = RM + 1480
DH Rear ceiling anchor = ET 200 DM Centre ceiling anchor = DH / 2 ET
Distance back
(1) = 2 × RM + 690 LH (2) = 2 × RM + 490 LH GIM Interior garage dimension
U Front operator boom suspension V1 Rear operator boom suspension W Total
distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Not possible as LPU 67 Thermo. · Not possible with break-in-resistant track
application RC 2!
SupraMatic HT
U
With short boom (K) up to door height 2125
1100
With medium boom (M) up to door height 2375
1100
With long boom (L) up to door height 3000
1300
With special boom length on request
V1 2775 3025 3700
W 3200
Length of operator boom
3000
3450
3250
4125
3925
Size range for LPU 42 with Wood-, Slate-, Deco-, Sand- and Duragrain surface
finish, Planar
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000 1900
Size range for LPU 42 with Silkgrain surface
3000 2850 2750 2600 2500 2375 2250 2205 2125 2080 2000 1900
LZ
LZ
Grid heights RM not possible with Decograin, S-panelled
36
Technical manual: Sectional garage doors / 03.2024
RM 2250 2375 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 5250 5500
RM 2250 2375 2500 2750 3000 3250 3500 3750 4000 4250 4500 4750 5000 5250 5500
Track application Z
(LPU 42) wicket door without threshold rail
Z = Tension spring track application
Manual operation
With operator
RM
Min. DE
LDH
Min. DE *
LDH
RM +125
RM 160
RM +125
RM 160
1900 1)
2025
1740
2025
1740
2000
2125
1840
2125
1840
2080
2205
1920
2205
1920
2125
2250
1965
2250
1965
2205
2330
2045
2330
2045
2250
2375
2090
2375
2090
- These versions are only available for S- / L-ribbed doors
INSIDE
v#
90 (105**)
INSIDE
$%& ‘ v# ( )01
90 (105**)
Notes: * For doors under thermal loads, you should place the operator 40 mm
higher if required (RM2 + 125 + 40).
** Clearance required for fitting doors with leading photocell (see page 55).
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 695 mm Max. DE with track suspension set I = 1456 = RM + 1423 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Due to the low threshold height, the ground in front of the garage must be
level or sloped to guarantee smooth opening of the wicket door (opening
outwards) see page 58.
· For doors up to RM 2250 mm in S-panelled version or in S-, M- or L-ribbed
version and with top glazing type D, S and M, the distance from FFL to the
bottom edge of the lintel must be equal to or greater than the ordering size
(RM). Deviating sizes on request!
· For DE > RM + 285 mm an additional 120 × 60 mm tubular profile is required
to strengthen the suspension construction in the area of the torsion springs.
· Not possible as LPU 67 Thermo.
SupraMatic P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2250 With special boom length on request
V1 2775 3025
W 3200 3450
175 (290**)
Technical manual: Sectional garage doors / 03.2024
37
Track application Z
(LPU 42) Wicket door with high threshold rail (85 mm)
Z = Tension spring track application
INSIDE
23
90 (105**)
INSIDE 0 456 7 23 8 9@
90 (105**)
Notes: * For doors under thermal loads, you should place the operator 40 mm
higher if required (RM + 125 + 40).
** Clearance required for fitting doors with leading photocell (see page 55).
Manual operation
With operator
RM
Min. DE
LDH
Min. DE *
LDH
RM + 125
RM 160
RM + 125
RM 145 2)
1900 1)
2025
1740
2025
1755
2000
2125
1840
2125
1855
2080
2205
1920
2205
1935
2125
2250
1965
2250
1980
2205
2330
2045
2330
2060
2250
2375
2090
2375
2090
-
These versions are only available for S- / L-ribbed doors
-
RM 160 for doors with push bar
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 695 mm Max. DE with track suspension set I = 1456 = RM + 1423 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Due to the low threshold height, the ground in front of the garage must be
level or sloped to guarantee smooth opening of the wicket door (opening
outwards) see page 58.
· For doors up to RM 2250 mm in S-panelled version or in S-, M- or L-ribbed
version and with top glazing type D, S and M, the distance from FFL to the
bottom edge of the lintel must be equal to or greater than the ordering size
(RM). Deviating sizes on request!
· For DE > RM + 285 an additional 120 × 60 tubular profile is required to
strengthen the suspension construction in the area of the torsion springs.
· Not possible as LPU 67 Thermo.
· Not possible with break-in-resistant track application RC 2!
SupraMatic P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2250 With special boom length on request
V1 2775 3025
W 3200 3450
175 (290**)
38
Technical manual: Sectional garage doors / 03.2024
Track application N
(LPU 42) wicket door without threshold rail
N = Normal track application
INSIDE
AB
90 (105**)
INSIDE
DEF G AB H IPQ
90 (105**)
Notes: * For doors under thermal loads, you should place the operator 40 mm
higher if required (RM + 235 + 40).
** Clearance required for fitting doors with leading photocell (see page 55).
SupraMatic P and HT With short boom (K) up to door height 2250 With medium boom (M) up to door height 2500 With long boom (L) up to door height 3000 With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
Manual operation
RM
Min. DE
LDH
RM +220
RM 160
1900
2120
1740
2000
2220
1840
2080
2300
1920
2125
2345
1965
2205
2425
2045
2250
2470
2090
2375
2595
2215
2500
2720
2340
2600
2820
2440
2750
2970
2590
2850
3070
2690
3000
3220
2840
- RM 160 for doors with push bar
With operator
Min. DE *
LDH
RM +235
RM 100 1)
2135
1800
2235
1900
2315
1980
2360
2025
2440
2105
2485
2150
2610
2275
2735
2400
2835
2500
2985
2650
3085
2750
3235
2900
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 520 Max. DE with track suspension set = RM
- 805 Max. DE with track suspension set I = 1456 = RM + 1533 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Due to the low threshold height, the ground in front of the garage must be
level or sloped to guarantee smooth opening of the wicket door (opening
outwards) see page 58.
· For doors up to RM 2250 mm in S-panelled versions or in S-, M- or L-ribbed
versions and with top glazing type D, S and M, the distance from FFL to the
bottom edge of the lintel must be equal to or greater than the ordering size
(RM). Deviating sizes on request!
· Not possible as LPU 67 Thermo.
Clearance required for fitting the multiple-point locking linking rods
175 (290**)
T S
R
DE RM
0
OFF 680 (940)
With wicket door LDB 1140
Technical manual: Sectional garage doors / 03.2024
39
Track application N
(LPU 42) Wicket door with high threshold rail (85 mm)
N = Normal track application INSIDE
Manual operation
RM
Min. DE
LDH
RM +220
RM 160
1900
2120
1740
2000
2220
1840
2080
2300
1920
2125
2345
1965
2205
2425
2045
2250
2470
2090
2375
2595
2215
2500
2720
2340
2600
2820
2440
2750
2970
2590
2850
3070
2690
3000
3220
2840
- RM 160 for doors with push bar
With operator
Min. DE *
LDH
RM +235
RM 95 1)
2135
1805
2235
1905
2315
1985
2360
2030
2440
2110
2485
2155
2610
2280
2735
2405
2835
2505
2985
2655
3085
2755
3235
2905
UV
90 (105**)
INSIDE
WXY ` UV a bcd
90 (105**)
Notes: * For doors under thermal loads, you should place the operator 40 mm
higher if required (RM + 235 + 40).
** Clearance required for fitting doors with leading photocell (see page 55).
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 520 Max. DE with track suspension set = RM
- 805 Max. DE with track suspension set I = 1456 = RM + 1533 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Due to the low threshold height, the ground in front of the garage must be
level or sloped to guarantee smooth opening of the wicket door (opening
outwards) see page 58.
· For doors up to RM 2250 mm in S-panelled version or in S-, M- or L-ribbed
version and with top glazing type D, S and M, the distance from FFL to the
bottom edge of the lintel must be equal to or greater than the ordering size
(RM). Deviating sizes on request!
· Not possible as LPU 67 Thermo.
· Not possible with break-in-resistant track application RC 2!
SupraMatic P and HT With short boom (K) up to door height 2250 With medium boom (M) up to door height 2500 With long boom (L) up to door height 3000 With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
175 (290**)
40
Technical manual: Sectional garage doors / 03.2024
Track application L
(LPU 42) wicket door without threshold rail
L = low headroom track application
INSIDE
ef
90 (105**)
INSIDE
ipr t ef u xy
90 (105**)
Notes: * For doors under thermal loads, you should place the operator 40 mm
higher if required (RM + 125 + 40).
** Clearance required for fitting doors with leading photocell (see page 55).
Manual operation
With operator
RM
Min. DE
LDH
Min. DE *
LDH
RM +125
RM 160
RM +125
RM 160
1900 1)
2025
1740
2025
1740
2000
2125
1840
2125
1840
2080
2205
1920
2205
1920
2125
2250
1965
2250
1965
2205
2330
2045
2330
2045
2250
2375
2090
2375
2090
2375
2500
2215
2500
2215
2500
2625
2340
2625
2340
2600
2725
2440
2725
2440
2750
2875
2590
2875
2590
2850
2975
2690
2975
2690
3000
3125
2840
3125
2840
- These versions are only available for S- / L-ribbed doors
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 695 mm Max. DE with track suspension set I = 1456 = RM + 1423 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Due to the low threshold height, the ground in front of the garage must be
level or sloped to guarantee smooth opening of the wicket door (opening
outwards) see page 58.
· For doors up to RM 2250 mm in S-panelled version or in S-, M- or L-ribbed
version and with top glazing type D, S and M, the distance from FFL to the
bottom edge of the lintel must be equal to or greater than the ordering size
(RM). Deviating sizes on request!
· For DE > RM + 285 mm an additional 120 × 60 mm tubular profile is required
to strengthen the suspension construction in the area of the torsion springs.
· Not possible as LPU 67 Thermo.
SupraMatic P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 3000 With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
175 (290**)
Technical manual: Sectional garage doors / 03.2024
41
Track application L
(LPU 42) Wicket door with high threshold rail (85 mm)
L = low headroom track application INSIDE
Manual operation
With operator
RM
Min. DE
LDH
Min. DE *
LDH
RM + 125
RM 160
RM + 125
RM 145 2)
1900 1)
2025
1740
2025
1755
2000
2125
1840
2125
1855
2080
2205
1920
2205
1935
2125
2250
1965
2250
1980
2205
2330
2045
2330
2060
2250
2375
2090
2375
2090
2375
2500
2215
2500
2230
2500
2625
2340
2625
2355
2600
2725
2440
2725
2455
2750
2875
2590
2875
2605
2850
2975
2690
2975
2705
3000
3125
2840
3125
2855
-
These versions are only available for S- / L-ribbed doors
-
RM 160 for doors with push bar
90 (105**)
INSIDE 0
90 (105**)
Notes: * For doors under thermal loads, you should place the operator 40 mm
higher if required (RM + 125 + 40).
** Clearance required for fitting doors with leading photocell (see page 55).
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 695 mm Max. DE with track suspension set I = 1456 = RM + 1423 ET Distance back GIM Interior garage dimension V1 Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Due to the low threshold height, the ground in front of the garage must be
level or sloped to guarantee smooth opening of the wicket door (opening
outwards) see page 58.
· For doors up to RM 2250 mm in S-panelled version or in S-, M- or L-ribbed
version and with top glazing type D, S and M, the distance from FFL to the
bottom edge of the lintel must be equal to or greater than the ordering size
(RM). Deviating sizes on request!
· For DE > RM + 285 an additional 120 × 60 tubular profile is required to
strengthen the suspension construction in the area of the torsion springs.
· Not possible as LPU 67 Thermo.
· Not possible with break-in-resistant track application RC 2!
SupraMatic P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 3000 With special boom length on request
V1 2775 3025 3700
W 3200 3450 4125
175 (290**)
42
Technical manual: Sectional garage doors / 03.2024
Track application BZ
BZ = Tension spring track application with flush-fitting panels
INSIDE
LZ
155 125
min. (105**) 90
INSIDE GIM LZ + 180
min. 90
(105**)
Notes:
** Clearance required for fitting doors with leading photocell (see page 55).
Clearance for lintel fitting with flush-fitting panel Without lintel
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600
RAM
min.
Max.
RM +190
2090
2395
2190
2520
2270
2620
2375
2675
2395
2770
2440
2830
2565
2870
2690
3020
2790
3140
Manual operation LDH
RM 80 1820 1920 2000 2045 2125 2170 2295 2420 2520
With operator LDH
RM 30 1870 1970 2050 2095 2175 2220 2345 2470 2570
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 405 Max. DE with track suspension set = RM
- 590 ET Distance back GIM Interior garage dimension
BH Panel height RAM Overall frame dimension =
ordering size Min. RAM = RM + 190 Max. RAM = 3170 LF Structural opening V1
Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Shortening the top door section or aluminium frame is not possible.
· Intermediate sizes possible, shortened from bottom · Not possible as LPU 67
Thermo. · Not possible with break-in-resistant track application RC 2!
ProMatic, SupraMatic E, P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 2600 With special boom length on request
V1 2847 3097 3772
W 3272 3522 4197
With lintel
Track application BZ and BL
RAM LF – 10 mm
Panel version PU fascia, S-, M- and L-ribbed S-panelled on request
DH Ceiling height RAM Bottom edge of lintel + 95 mm TB Door leaf * Suspension
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 600
Technical manual: Sectional garage doors / 03.2024
43
Track application BZ
(LPU 42) wicket door without threshold rail
BZ = Tension spring track application with flush-fitting panels
INSIDE
175 (290**)
90 (105**)
INSIDE
d
90 (105**)
Notes:
** Clearance required for fitting doors with leading photocell (see page 55).
Clearance for lintel fitting with flush-fitting panel Without lintel
RM
1900 2000 2080 2125 2205 2250
RAM
min.
Max.
RM +190
2090
2395
2190
2520
2270
2620
2315
2675
2395
2770
2440
2830
Manual operation LDH
RM 160 1740 1840 1920 1965 2045 2090
With operator LDH
RM 160 1740 1840 1920 1965 2045 2090
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 405 Max. DE with track suspension set = RM
- 590 ET Distance back GIM Interior garage dimension
BH Panel height RAM Overall frame dimension =
ordering size Min. RAM = RM + 190 Max. RAM = 3170 LF Structural opening V1
Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Shortening the top door section or aluminium frame is not possible.
· Intermediate sizes possible, shortened from bottom · Not possible as LPU 67
Thermo. · Not possible with break-in-resistant track application RC 2!
SupraMatic P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2250 With special boom length on request
V1 2775 3025
W 3200 3450
With lintel
Track application BZ and BL
RAM LF – 10 mm
Panel version PU fascia, S-, M- and L-ribbed S-panelled on request
44
DH Ceiling height RAM Bottom edge of lintel + 95 mm TB Door leaf * Suspension
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 600
Technical manual: Sectional garage doors / 03.2024
Track application BZ
(LPU 42) Wicket door with high threshold rail (85 mm)
BZ = Tension spring track application with flush-fitting panels
INSIDE
ef
175 (290**)
90 (105**)
INSIDE
ghi j ef k lmn
90 (105**)
Notes:
** Clearance required for fitting doors with leading photocell (see page 55).
Clearance for lintel fitting with flush-fitting panel Without lintel
RM
1900 2000 2080 2125 2205 2250
RAM
min.
Max.
RM +190
2090
2395
2190
2520
2270
2620
2315
2675
2395
2770
2440
2830
Manual operation LDH
RM 160 1740 1840 1920 1965 2045 2090
With operator LDH
RM 160 1740 1840 1920 1965 2045 2090
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 405 Max. DE with track suspension set = RM
- 590 ET Distance back GIM Interior garage dimension
BH Panel height RAM Overall frame dimension =
ordering size Min. RAM = RM + 190 Max. RAM = 3170 LF Structural opening V1
Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Shortening the top door section or aluminium frame is not possible.
· Intermediate sizes possible, shortened from bottom · Not possible as LPU 67
Thermo. · Not possible with break-in-resistant track application RC 2!
SupraMatic P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2250 With special boom length on request
V1 2775 3025
W 3200 3450
With lintel
Track application BZ and BL
RAM LF – 10 mm
Panel version PU fascia, S-, M- and L-ribbed S-panelled on request
DH Ceiling height RAM Bottom edge of lintel + 95 mm TB Door leaf * Suspension
Max. DE standard suspension = RM + 410 Max. DE with track suspension set = RM
- 600
Technical manual: Sectional garage doors / 03.2024
45
Track application BL
BL = Low headroom track application with flush-fitting panel
INSIDE
155 125
LZ
min. (105**) 90
INSIDE GIM LZ + 180
min. 90
(105**)
Notes:
** Clearance required for fitting doors with leading photocell (see page 55).
Clearance for lintel fitting with flush-fitting panel Without lintel
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
RAM
min.
Max.
RM +190 2090 2190 2270 2315 2395 2440 2565 2690 2790 2940 3040 3190
2395 2520 2620 2675 2770 2830 2870 3020 3140 3320 3345 3520
Manual operation
LDH
RM 100 1800 1900 1980 2025 2105 2150 2275 2400 2500 2650 2750 2900
With operator
LDH up to LZ 3000
LDH from LZ 3010
RM 30
RM 80
1870
1820
1970
1920
2050
2000
2095
2045
2175
2125
2220
2170
2345
2295
2470
2420
2570
2520
2720
2670
2820
2770
2970
2920
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 405 Max. DE with track suspension set = RM
- 590 ET Distance back GIM Interior garage dimension
BH Panel height RAM Overall frame dimension =
ordering size Min. RAM = RM + 190 Max. RAM = 3520 LF Structural opening V1
Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Shortening the top door section or aluminium frame is not possible.
· Intermediate sizes possible, shortened from bottom · Not possible as LPU 67
Thermo. · Not possible with break-in-resistant track application RC 2!
ProMatic, SupraMatic E, P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 3000 With special boom length on request
V1 2847 3097 3772
W 3272 3522 4197
With lintel
Track application BZ and BL
RAM LF – 10 mm
Panel version PU fascia, S-, M- and L-ribbed S-panelled on request
46
DH Ceiling height RAM Bottom edge of lintel + 95 mm TB Door leaf * Suspension
= max. DE standard suspension = RM + 410
Max. DE with track suspension set = RM + 600
Technical manual: Sectional garage doors / 03.2024
Track application BL
(LPU 42) wicket door without threshold rail
BL = Low headroom track application with flush-fitting panel
INSIDE
LZ
175 (290**)
90 (105**)
INSIDE GIM LZ + 180
90 (105**)
SupraMatic P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 3000 With special boom length on request
V1 2847 3097 3772
Clearance for lintel fitting with flush-fitting panel Without lintel
W 3272 3522 4197
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
RAM
min.
Max.
RM +190
2090
2395
2190
2520
2270
2620
2315
2675
2395
2770
2440
2830
2565
2870
2690
3020
2790
3140
2940
3320
3040
3345
3190
3520
Manual operation LDH
RM 160 1740 1840 1920 1965 2045 2090 2215 2340 2540 2590 2690 2840
With operator LDH
RM 160 1740 1840 1920 1965 2045 2090 2215 2340 2540 2590 2690 2840
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 405 Max. DE with track suspension set = RM
- 590 ET Distance back GIM Interior garage dimension
BH Panel height RAM Overall frame dimension =
ordering size Min. RAM = RM + 190 Max. RAM = 3520 LF Structural opening V1
Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Due to the low threshold height, the ground in front of the garage must be
level or sloped to guarantee smooth opening of the wicket door (opening
outwards) see page 58.
· Shortening the top door section or aluminium frame is not possible.
· Not possible as LPU 67 Thermo. · Not possible with break-in-resistant track
application RC 2!
Note: ** Clearance required for fitting doors with leading photocell
(see page 55).
With lintel
Track application BZ and BL
RAM LF – 10 mm
Panel version PU fascia, S-, M- and L-ribbed S-panelled on request
DH Ceiling height RAM Bottom edge of lintel + 95 mm TB Door leaf * Suspension
= max. DE standard suspension = RM + 410
Max. DE with track suspension set = RM + 600
Technical manual: Sectional garage doors / 03.2024
47
Track application: BL
(LPU 42) Wicket door with high threshold rail (85 mm)
BL = Low headroom track application with flush-fitting panel
INSIDE
LZ
175 (290**)
90 (105**)
INSIDE GIM LZ + 180
90 (105**)
SupraMatic P and HT With short boom (K) up to door height 2125 With medium boom (M) up to door height 2375 With long boom (L) up to door height 3000 With special boom length on request
V1 2847 3097 3772
Clearance for lintel fitting with flush-fitting panel Without lintel
W 3272 3522 4197
RM
1900 2000 2080 2125 2205 2250 2375 2500 2600 2750 2850 3000
RAM
min.
Max.
RM +190
2090
2395
2190
2520
2270
2620
2315
2675
2395
2770
2440
2830
2565
2870
2690
3020
2790
3140
2940
3320
3040
3345
3190
3520
Manual operation LDH
RM 160 1740 1840 1920 1965 2045 2090 2215 2340 2540 2590 2690 2840
With operator LDH
RM 145 1755 1855 1935 1980 2060 2090 2230 2355 2455 2605 2705 2855
LDH Clear passage height RM Grid height LZ Clear frame dimension DE Ceiling
height
Max. DE standard suspension = RM + 405 Max. DE with track suspension set = RM
- 590 ET Distance back GIM Interior garage dimension
BH Panel height RAM Overall frame dimension =
ordering size Min. RAM = RM + 190 Max. RAM = 3520 LF Structural opening V1
Rear operator boom suspension W Total distance back including operator head
Notes:
· It is imperative that you maintain the clearance for fitting and subsequent
operation of the door.
· Due to the low threshold height, the ground in front of the garage must be
level or sloped to guarantee smooth opening of the wicket door (opening
outwards) see page 58.
· Shortening the top door section or aluminium frame is not possible.
· Not possible as LPU 67 Thermo. · Not possible with break-in-resistant track
application RC 2!
Note: ** Clearance required for fitting doors with leading photocell
(see page 55).
With lintel
Track application BZ and BL
RAM LF – 10 mm
Panel version PU fascia, S-, M- and L-ribbed S-panelled on request
48
DH Ceiling height RAM Bottom edge of lintel + 95 mm TB Door leaf * Suspension
= max. DE standard suspension = RM + 410
Max. DE with track suspension set = RM + 600
Technical manual: Sectional garage doors / 03.2024
24 160-180
Siderooms
Track applications Z, N, L, H
Normal track application, sideroom 90 mm, fixing inside the frame
58
LZ LF
LF**
15
58 15
INSIDE
90
GIM LZ + 180
90
Sideroom less than 75 mm orwithout sideroom, fixing of the frame with special anchor
12
78
LF
LZ
15 75
Z 90
INSIDE
AS
90 125
GIM LZ + 180
Min. sideroom 75 mm, fixing outside the frame
75
LF
48 50
LZ
Z 55/90
90 125
75
50
8
125
INSIDE
opq r st u vwx
125
min.
**
Max.
LZ Clear frame dimension
LF
Structural opening
GIM Z 55 Z 90 AS
Interior garage dimension Frame covering 55 Frame covering 90 Special anchor
Technical manual: Sectional garage doors / 03.2024
RAMB Overall frame dimension width TB Door leaf
49
Siderooms
Version with break-in-resistant track application RC 2 according to DIN / TS
18194
Track applications Z, N, L,
Normal track application, sideroom 90 mm, fixing inside the frame
58
LZ LF
58
LF**
15
15
24
INSIDE
90
GIM LZ + 180
}~
75
}
50 48
Z 55/90
90
58
y z{|
ThermoFrame set with RC 2
LZ LF
58
LF**
15
LZ – 12
58
R 120×60
Note:
Requirements for the building structure can be found in DIN EN 1627:2011 or
the fitting instructions for the RC 2 set according to DIN/TS 18194, art. no.
4018939!
58
R 160×60
BOS
75
¡
70
Z 55/90
90 GIM LZ + 180
Frame support set with RC 2
LZ – 12
58 19
LZ LF 6
125
GIM LZ + 180
¢ £¤
min.
**
Max.
LZ Clear frame dimension
LF
Structural opening
50
GIM Z 55 Z 90 AS
Interior garage dimension Frame covering 55 Frame covering 90 Special anchor
RAMB Overall frame dimension width TB Door leaf
Technical manual: Sectional garage doors / 03.2024
17
Siderooms
Renovation solution
Fitting in the opening Fascia frame -95-
95-125
RAMB = LZ + 190*/280** LZ
95-135
AS
Fitting in front of the reveal Fascia frame -125-
125-165 max. 125
INSIDE GIM = LZ + 190*/260*
RAMB = LZ + 250/330** LZ
¥¦§¨¥©§
160-180
160-180 17
INSIDE AS
GIM = LZ + 190*/260**
Fitting behind the opening Retrofit fascia
RAMB = LZ + 24*/120**
ª«
Z 55/90
INSIDE AS
GIM = LZ + 190*/260**
min.
**
Max.
LZ Clear frame dimension
LF
Structural opening
GIM Z 55 Z 90 AS
Interior garage dimension Frame covering 55 Frame covering 90 Special anchor
Technical manual: Sectional garage doors / 03.2024
69
11.5 40
RAMB Overall frame dimension width TB Door leaf
51
Siderooms
Solutions with special anchor, box section or with thermal insulation
composite systems
Track applications Z, N, L, H
Sideroom less than 75 mm orwithout sideroom, fixing of the frame with special anchor
LF
12
78
LZ
Z 90
LF LZ LZ – 12
15 75
25
INSIDE AS
90 125
Special anchor set 1
90 -100
GIM LZ + 180
90 -125
GIM LZ + 180
90 125
Special anchor set 2
90 -100
30 160-180
90 -140
175 – 240 175 – 240
160 -180
160 -180
Fixing of the frame to a box section
°±
¬ ®¯
58
R 120×60
¶·
² ³´µ
58
R 160×60
ST 8×30 BOS
Frame fixing to tube with fixed element using special anchor
Frame fixing when using a thermal insulation composite system
WDVS 150 ( 100)
LZ LF
INSIDE
48 170 (120)
INSIDE
min.
**
Max.
*** Sets 1 and 2 not possible for intermediate heights
LZ Clear frame dimension
52
LF GIM Z 55 Z 90
Structural opening Interior garage dimension Frame covering 55 Frame covering 90 mm
AS Special anchor RAMB Overall frame dimension width TB Door leaf WDVS Thermal
insulation composite system
Technical manual: Sectional garage doors / 03.2024
Fitting solutions
Special anchor extension set IDL (in the reveal)
48
400
Fitting solution with side door NT 60, fixed element and LPU 42
Note:
¸¹ º» ¼¹½ ¾¿ÀÁ ÂÃÄÅ ÄÆÄÇÄÈÀÉ Ê¼Ë ÌÍ
¾¿ÀÁ ÎÏÄпÑÆ ÑÈÐÁÒÓ ÎÄÀ ½ ÑÈÅ ÔÒÃ
ÎÄÐÀ¿ÒÈ 60 × 120 mm.
R 120×60
INSIDE 220
Technical manual: Sectional garage doors / 03.2024
53
Sideroom and lintel fitting with ThermoFrame
Track applications Z, N, L, H with ThermoFrame
Normal track application, sideroom 90 mm, fixing inside the frame
58 15
LZ LF LF**
LZ – 12
58 15
Frame support set
LZ – 12
58 19
LZ LF 6
INSIDE
90
GIM LZ + 180
Lintel fitting with ThermoFrame
LPU 42 ***
LPU 42 / 67 (sets 4 5)
90
GIM LZ + 180
Õ Ö×
LPU 67 Thermo (sets 6 7)
LPU 67 Thermo with aluminium frame (sets 8 9)
RM
INSIDE
RM
INSIDE
RM
INSIDE
RM
INSIDE
TB
TB
Wicket door with and without rain canopy Without rain canopy (4 door sections)
TB TB
With rain canopy (> 4 door sections)
min.
**
Max.
*** Only possible for track application H
LZ Clear frame dimension
54
LF GIM Z 55 Z 90
Structural opening Interior garage dimension Frame covering 55 Frame covering 90 mm
AS Special anchor RAMB Overall frame dimension width TB Door leaf WDVS Thermal
insulation composite system
Technical manual: Sectional garage doors / 03.2024
Sideroom and lintel fitting
Clearance for leading photocell (VL 1 / VL 2)
Notes:
· Not possible with chamfered height adjustment of the bottom door section
(track application SN / SL)
· Not possible with variable bottom profile
290
105
Clearance for operator rail with folding roller bracket set (ventilation position)
Ceiling height = RM + X
X
A 42
210 275
135 165
B
210 220
115 145
X
42
C
210 275
135 165
D 67
210 220
115 145
Calculation of the ventilation cross-section for folding roller bracket set
(in mm²)
· For sectional garage doors with track application N TH × 0.26 × LZ · For
sectional garage doors with track application L TH × 0.45 × LZ · For sectional
garage doors with track application Z TH × 0.45 × LZ
Notes:
· Not possible for track application H, track application BZ, track
application BL and doors with wicket door with 4 sections.
· Choose the maximum required headroom for doors under thermal load with
folding roller bracket.
LZ Clear frame dimension RM Grid height TH Door section height
Technical manual: Sectional garage doors / 03.2024
55
160-180
Sideroom and lintel fitting with LTH 42
With frame / panel cladding
LTH 42 sideroom
Sideroom 90 mm, normal track application, fixing inside the frame
Min. sideroom 75 mm, fixing outside the frame
LZ
110
78
LF
ÜÝ
20
78
22
Sideroom less than 75 mm orwithout sideroom, fixing of the frame with special
anchor
LF LZ
INSIDE
90
INSIDE
Ø ÙÚÛ
LTH 42 lintel fitting (a steel fascia is included in the scope of delivery for LTH 42 doors!)
View A
View B
INSIDE
View C
90 125
x
x
x
RM – 20
RM – 20
TB
INSIDE
Track application N and L
Frame / panel cladding LTH 42
Set ZV / BL 1 & 2 Set ZV / BL 3 & 4 Set ZV / BL 5 & 6
â á à
ß
Þ
TB
INSIDE
View A 115 mm
TB
INSIDE
Dimension x View B
116 300 mm
View C
301 500 mm
56
Technical manual: Sectional garage doors / 03.2024
Lintel fitting with fascia panels
LPU 42, LPU 67 Thermo
View A LPU 42
LPU 67 Thermo
View B
View C
View IDL
x
x
x
x
x
55
RM
RM
RM
RM
RM
TB INSIDE
TB INSIDE
TB INSIDE
TB INSIDE
TB INSIDE
Track application
ãä å æçè é
Panel version
Steel fascia (in scope of delivery) PU panel, S- / L-ribbed (depth 42 mm) PU
panel, S- / L-ribbed (depth 67 mm) PU fascia, M-ribbed PU fascia, S-panelled
LPU 42 Aluminium fascia panel
Retrofit fascias Fascia frame -95-
View A Up to 100 mm
Dimension x View B
61 562 mm 125 562 mm 250 562 mm
View C
61 562 mm 125 562 mm 250 562 mm 475, 500, 520, 525, 531,
550, 562
Fascia frame -125-
Retrofit fascia
210
100
180
ì ì ë
ê
TB
TB
TB
RM
RM
TB
INSIDE
î í
INSIDE
INSIDE
RM
Attention: Observe the frame’s plug-and-screw fitting points in the lintel area, since they are subject to an increased torque with track application N (torsion spring).
TB
Door leaf
RM
Grid height
LDH LF
Clear passage height Structural opening
INSIDE
Technical manual: Sectional garage doors / 03.2024
57
Bottom edge
Without wicket door
INSIDE
LPU 67 Thermo without wicket door INSIDE
RM
5°
13
115 INSIDE EW
INSIDE
RM
10
RM
115
45 EW
INSIDE
115
INSIDE
EW
Drainage
RM
Standard size
58
Technical manual: Sectional garage doors / 03.2024
Bottom edge
With wicket door
INSIDE
This fitting situation is not possible due to the threshold profile!
With wicket door and high threshold rail (85 mm) INSIDE EW
RM 10 RM
RM 85 80
115 INSIDE
EW 900 (1210)
122 INSIDE
900 (1210) EW 122
for wicket door width 1140 mm
EW
Drainage
RM
Standard size
Technical manual: Sectional garage doors / 03.2024
59
Bottom edge
Chamfered height adjustment of the bottom door section (track application SN / SL)
RM 2
RM 2 RM 1
RM 1
L
R
H
H
Left Chamfered bottom section view of fitting side (from inside) H = Height
difference min. 20 mm / max. 300 mm
Adjustable bottom profile
max. 20
ï
ñ ð
INSIDE
ï
Right
Notes: · Only possible for LPU 42 with track application N or L up to
LZ 6000 mm! · Not for versions with wicket door or panelled doors! · LDH
reduced by H. · RM 1 / RM 2 = min. 2000 mm.
H = Height difference min. 0 mm / max. 20 mm
Notes: · Not possible for versions with wicket door or ART42 · LDH reduced by
H. · Not possible with VL 1 / VL 2, chamfered height adjustment and
adjustment from the bottom · Version with low-track door set or frame
compensation set
possible
Low-track door set (fitting in front of the reveal)
With 20 N 30 mm LDH = RM 110 mm without operator
Reno RC set
With N 30 mm LDH = RM 110 mm without operator
Wind threshold
LDH 18
RM**
RM* 20 N 30 20
OFF OFF
N 30
18
7
17
60
77
Note:
- RM (door leaf) = FFL RM (frame) = FFL 25
INSIDE
LDH N
RM
Clear passage height Height difference between interior and exterior garage floor Standard size
60
50 – 60
INSIDE
Note:
** RM (door leaf) = RM (frame) only possible for track application Z
22
79
INSIDE
Note:
Not possible for LPU 42 with wicket door and LPU 67.
Technical manual: Sectional garage doors / 03.2024
Fixed elements
External views S-ribbed
M-ribbed
L-ribbed
D-ribbed
Possible fitting options Behind the opening
INSIDE
In the opening
60
RAMH = LF + 60
10
60 RAMH = LF 10 LF
Fitting examples
R 120 × 60 R 160 × 60
4 òó ôõ ö ÷õ ö
R 120 × 60 R 160 × 60
A 4 ó ôõ ö ÷õ ö
INSIDE
AW 60 × 40 × 4
AW 60 × 40 × 4
Height table of ribbed versions
B
RM
A
475
I øùúúû üýþÿû ü ÿú
1
475
I øùúúû üýþÿû ü ÿú
2
475
I øùúúû üýþÿû ü ÿú
3
475
I øùúúû üýþÿû ü ÿú
4
475
I øùúúû üýþÿû ü ÿú
5
475
I øùúúû üýþÿû ü ÿú
6
500
üúúúû üÿúúû ýúúú
1
500
üúúúû üÿúúû ýúúú
2
500
üúúúû üÿúúû ýúúú
3
500
üúúúû üÿúúû ýúúú
4
500
üúúúû üÿúúû ýúúú
5
500
üúúúû üÿúúû ýúúú
6
520
I P üú úû ü úú
1
520
I P üú úû ü úú
2
520
I P üú úû ü úú
3
520
I P üú úû ü úú
4
520
I P üú úû ü úú
5
520
I P üú úû ü úú
6
531
2125
1
531
2125
2
531
2125
3
531
2125
4
531
2125
5
531
2125
6
550
üüúÿû üþÿú
1
550
üüúÿû üþÿú
2
550
üüúÿû üþÿú
3
550
üüúÿû üþÿú
4
550
üüúÿû üþÿú
5
550
üüúÿû üþÿú
6
In the opening
Min. RAMH
100 575 1050 1525 2000 2475 100 600 1100 1600 2100 2600 100 620 1140 1660 2180
2700 100 631 1162 1693 2224 2755 100 650 1200 1750 2300 2850
Max. RAMH
503 978 1453 1928 2403 2878 528 1028 1528 2028 2528 3028 548 1068 1588 2108
2628 3148 559 1090 1621 2152 2953 3214 578 1128 1678 2228 2778 3328
Behind the opening
RAMH
535 1010 1485 1960 2435 2910 560 1060 1560 2060 2560 3060 580 1100 1620 2140
2660 3180 591 1122 1653 2185 2716 3247 610 1160 1710 2260 2810 3360
RAMH
B
RM
562
2250
562
2250
562
2250
562
2250
562
2250
562
2250
200 600 2500 3000 3500 5500
135 ET ET ET ET ET ET
In the opening
Behind the opening
A Min. RAMH Max. RAMH
1
100
2
662
3
1224
4
1786
5
2348
6
2910
590 1152 1714 2276 2838 3400
RAMH
622 1185 1747 2310 2872 3435
Size range in mm for packaging type
600
600
2500
3000
ET
ET
ET
ET
ET
ET
ET
ET
ET
ET
ET
ET
ET
ET
ET
MT
ET
MT
MT
MT
ET
RAMB
5500 ET ET MT MT MT
ET Created in one-part / in box MT Created in multiple parts
Note: RAMB at least 135 mm.
A
No. of door sections
B
Door section height
AW Aluminium bracket
LF
Structural opening
RAMB Overall frame dimension width
RAMH Overall frame height
RM Grid height
Technical manual: Sectional garage doors / 03.2024
61
Side doors NT 60
With corner frame made of aluminium profiles Standard / special sizes
External views
(The dimensions in the illustrations correspond to the size of the structural opening for 1000 × 2125 mm. Deviations may occur with other door sizes.)
Profile type 1
Profile type 2
DRH
1050
Standard sizes
Profile type 1, only opening inwards, S-, M-, L-ribbed or S-panelled Fitting: internal fitting
Ordering sizes = LMB
DRH from FFL
B
875 × 2000
955
500
875 × 2125
1010
531
1000 × 2000
955
500
1000 × 2125
1010
531
Special sizes
Profile type 1 internal fitting with S- / M- / L-ribbing
B
RM
A
BRB*
Min. BRH Max. BRH
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
4 550 1284 4 550 1284 4 550 1284 4 550 1284 4 550 1284 4 550 1284 5 550 1284 5 550 1284 5 550 1284 5 550 1284 5 550 1284 5 550 1284
1800 1800 1800 1800 1800 1804 2018 2118 2198 2242 2318 2366
1963 2063 2143 2187 2263 2311 2438 2500 2500 2500 2500 2500
DRH
911 955 990 1010 1043 1064 911 955 990 1010 1043 1064
Profile type 1 internal fitting, S-panelled
B
RM
A
BRB* Min. BRH Max. BRH
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
475 1900, 2375, 2850
500
2000
4 633 1284 4 633 1284 4 633 1284 4 633 1284 4 633 1284 4 633 1284 5 633 1284 5 633 1284
1911 1998 2068 2107 2173 2215 2386 2498
1963 2063 2143 2187 2263 2311 2438 2500
DRH
911 955 990 1010 1043 1064 911 955
Profile type 2 With S- / M- / L-ribbing Fitting: internal or external fitting
Ordering sizes = LMB
DRH from FFL
B
875 × 2000
1050
500
875 × 2125
1050
531
1000 × 2000
1050
500
1000 × 2125
1050
531
Profile type 2 internal and external fitting with S- / M- / L-ribbing ***
B
RM
A
BRB* Min. BRH** Max. BRH
DRH
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
4 550 1284 4 550 1284 4 550 1284 4 550 1284 4 550 1284 4 550 1284 5 550 1284 5 550 1284 5 550 1284 5 550 1284 5 550 1284 5 550 1284
1800 1800 1800 1800 1800 1804 2018 2118 2198 2242 2318 2366
1986 2086 2166 2210 2286 2334 2461 2500 2500 2500 2500 2500
1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050
- Glazing min. BRB: aluminium frame = 550 mm, S window (S-, M-, L-ribbed) = 603 mm, S window (S-panelled) = 633 mm, M window = 828 mm, D window = 888 mm
** BRH < 1800 only with profile type 2 and DRH = BRH / 2 possible on request *** 3-point locking from BRH > 1900 mm
Note: Smaller doors possible on request
A
No. of door sections
B
Door section height
BRB Nominal size width
62
BRH Nominal size height DRH Lever height RM Grid height
Technical manual: Sectional garage doors / 03.2024
Side doors NT 60
With corner frame made of aluminium profiles Standard / special sizes
67 FLAM = BRB 4
Profile type 1 (only opening inwards)
5 38 9
Profile type 2 (opening inwards)
5 38 52,5
Profile type 2 (opening outwards)
118
12°
INSIDE
118
118
Internal fitting
External fitting
INSIDE
INSIDE
12°
5 38 52,5
Internal fitting (opening inwards), profile type 1 or 2
LH hinged
LMB BRB = LMB 10 LDB = BRB 76
H BRH = LMH 10 LDH = BRH 38 RAMH = BRH + 28 (LMH + 18)
RAMH = BRH + 28 (LMH + 18)
LDH = BRH 38
BRH = LMH 10
v
Profile type 1, 2
50
LMH
RH hinged
RAMB = BRB + 56 (LMB + 46)
External fitting (opening outwards), profile type 2
RAMB = BRB + 56 (LMB + 46) 12
LH hinged
RH hinged
LDB = BRB 76 BRB = LMB 10
LMB
Clear passage width with 90° leaf opening
28
36
90°
INSIDE
25,5
LDB 90° = BRB 114 = LDB 26
Adjustment from the bottom
13 20 5
25 27 60
Note: · Different design / performance characteristics · Not possible with
aluminium frames
BRB BRH FLAM LDB
Nominal size width Nominal size height Exterior leaf dimension Clear passage width
LDB 90° Clear passage width at an opening angle of 90° LDH Clear passage height LMB Structural opening width LMH Structural opening height
RAMB Overall frame dimension width RAMH Overall frame height
Technical manual: Sectional garage doors / 03.2024
63
Side doors NT 60
With block frame made of aluminium profiles Standard sizes
External views
(The dimensions in the illustrations correspond to the size of the structural opening for 1000 × 2125 mm. Deviations may occur with other door sizes.)
Profile type 1
Profile type 2
DrH 1050
Standard sizes (profile type 1, only opening inwards)
Profile type 1 (fitting behind the opening) S- / M- / L-ribbed, S-panelled
Ordering
LF of the opening
DRH from FFL
B
sizes = RAM
855 875 × 1990 2000
990 × 2058
955
500
855 875 × 2115 2125
990 × 2183
1010
531
980 1000 × 1990 2000
1115 × 2058
955
500
980 1000 × 2115 2125
1115 × 2183
1010
531
Profile type 2 (fitting behind the opening) S- / M- / L-ribbed, S-panelled
Ordering
LF of the opening
DRH from FFL
B
sizes = RAM
855 875 × 1990 2000
990 × 2058
1050
500
855 875 × 2115 2125
990 × 2183
1050
531
980 1000 × 1990 2000
1115 × 2058
1050
500
980 1000 × 2115 2125
1115 × 2183
1050
531
Profile type 2 (fitting in the opening) With S- / M- / L-ribbing
Ordering
LF of the opening
DRH from FFL
B
sizes = RAM
875 × 2000
855 × 1990
1050
500
875 × 2125
855 × 2115
1050
531
1000 × 2000
980 × 1990
1050
500
1000 × 2125
980 × 2115
1050
531
Note with glazing type D: min. RAM width 935 mm.
B DRH LF RAM
Door section height Lever height Structural opening Overall frame dimension
64
Technical manual: Sectional garage doors / 03.2024
Side doors NT 60
With block frame made of aluminium profiles Standard sizes
Profile type 1 9
Profile type 2 52,5
Profile type 1 / 2 60
Profile type 1 / 2 Panel in front of the side door
Profile type 1 / 2 Panel over the side door
Profile type 1 / 2
60
68 37
36 BH 68 BH
68 68
67
INSIDE
120
120
68
LMB = LDB
68
55 25,5
20 5
LMH = LDH LDH
RAMH
RAMH 13
60
10 68
INSIDE RAMB = LMB + 136
68 10
INSIDE RAMB = LMB 20 LMB
Fitting arrangements Fitting in the opening Fitting next to the garage door,
opening inwards or outwards, RH or LH hinged
Fitting in the opening, opening inwards or outwards, RH or LH hinged
INSIDE
OFF
OFF
RAMB
LDB RAMB LDB
INSIDE INSIDE
LDH
OFF
25 27 60
14
25 68
LDB
RAMB
LDB RAMB
INSIDE
Fitting behind the opening Only opening inwards, RH or LH hinged
Note: Dowel holes in the frame must be selected additionally (not standard).
LMB LDB
RAMB
INSIDE
Clear passage width with 90° leaf opening
LDB 90° = RAMB 162* = LDB 26
90°
FLAM = RAMB 43
- BH FLAM LDB
148 mm for concealed hinges Panel height Exterior leaf dimension Clear passage width
LDB 90° Clear passage width at an opening angle of 90° LDH Clear passage height LMB Structural opening width LMH Structural opening height
RAMB Overall frame dimension width RAMH Overall frame height
Technical manual: Sectional garage doors / 03.2024
65
Side doors NT 60
With block frame made of aluminium profiles Special sizes
External views
(The dimensions in the illustrations correspond to the size of the structural opening for 1000 × 2125 mm. Deviations may occur with other door sizes.)
Profile type 2
1 ¡¢£
1 ¡¢£
DrH
Special sizes (profile type 1, only opening inwards)
Profile type 1 (fitting in or behind the opening), S- / M- / L-ribbed
Min.
Max.
B
RM
A
RAMB*
RAMH
RAMH
DRH
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
475
2375
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
4 550 1330 4 550 1330 4 550 1330 4 550 1330 4 550 1330 4 550 1330 5 550 1330 5 550 1330 5 550 1330 5 550 1330 5 550 1330 5 550 1330
1800 1800 1800 1800 1800 1825 2039 2139 2219 2263 2339 2387
1983 2083 2163 2207 2283 2331 2458 2558 2558 2558 2558 2558
911 955 990 1010 1043 1064 911 955 990 1010 1043 1064
Profile type 1 (fitting behind the opening), S-panelled
Min.
Max.
B
RM
A
RAMB
RAMH
RAMH
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
475 1900, 2375, 2850
500
2000
4 725 1330 4 725 1330 4 725 1330 4 725 1330 4 725 1330 4 725 1330 5 725 1330 5 725 1330
1931 2019 2089 2127 2194 2236 2406 2519
1983 2083 2163 2207 2283 2331 2458 2558
DRH
911 955 990 1010 1043 1064 911 955
- Glazing type D: min RAMB = 935 mm or panel glazing type M: min RAMB = 875 mm ** RAMH < 1800 only with profile type 2 and DRH = RAMH / 2 possible on request *** 3-point locking from RAMH > 1910 mm
Profile type 2 (fitting in or behind the opening), S- / M- / L-ribbed ***
Min.
Max.
B
RM
A RAMB* RAMH** RAMH
DRH
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
4 550 1330 4 550 1330 4 550 1330 4 550 1330 4 550 1330 4 550 1330 5 550 1330 5 550 1330 5 550 1330 5 550 1330 5 550 1330 5 550 1330
1800 1800 1800 1800 1800 1825 2039 2139 2219 2263 2339 2387
2007 2107 2187 2231 2307 2355 2482 2558 2558 2558 2558 2558
1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050
Profile type 2 (fitting behind the opening), S-panelled
Min.
Max.
B
RM
A
RAMB
RAMH
RAMH
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
475 1900, 2375, 2850
4 725 1330 4 725 1330 4 725 1330 4 725 1330 4 725 1330 4 725 1330 5 725 1330
1973 2061 2131 2169 2236 2278 2448
2007 2107 2187 2231 2307 2355 2482
DRH
1050 1050 1050 1050 1050 1050 1050
Note: Smaller doors possible on request
A
No. of door sections
B
Door section height
DRH Lever height
RAMB Overall frame dimension width
66
RAMH Overall frame height RM Grid height
Technical manual: Sectional garage doors / 03.2024
Side doors NT 60
With block frame made of aluminium profiles Special sizes
RAMH 67
LMH = LDH 68
RAMH = LMH 10 120
Fitting next to the door, opening outwards, RH or LH hinged
RAMB
Fitting next to the door, opening inwards, RH or LH hinged
10 68
LDB
68 120
INSIDE
10 68
LDB = RAMB 136
R 68 120
R INSIDE RAMB
Fitting in the opening, opening inwards or outwards, RH or LH hinged LMB
RAMB = LMB 20
Fitting behind the opening, opening inwards, RH or LH hinged
68
LMB = LDB
130
with support bracket
10 68
LDB = RAMB 136 INSIDE
68 10
Fitting behind the opening 60
Fitting in the opening
10
RAMB INSIDE
Clear passage width with 90° leaf opening With surface-mounted hinges, maximum
opening angle 180°
LDB 90° = RAMB 162* = LDB 26
90°
FLAM = RAMB 43
LMH
LDH = LMH 78
INSIDE
OFF
INSIDE
Note: Dowel holes in the frame must be selected additionally (not standard).
Adjustment from the bottom
With concealed hinges, maximum opening angle 162° LDB 90° = RAMB 148 = LDB
13
90°
FLAM = RAMB 78
Note: · Different design / performance characteristics · Not possible with aluminium frames
DRH Lever height FLAM Exterior leaf dimension LDB Clear passage width LDB 90° Clear passage width at an opening angle of 90°
LDH LMB LMH R
Clear passage height Structural opening width Structural opening height Box section
Technical manual: Sectional garage doors / 03.2024
RAMB Overall frame dimension width RAMH Overall frame height
67
Side doors NT 60
Double-leaf side doors with block frame made of aluminium profiles
60
Fitting in the opening, profile type 2, opening inwards or outwards, RH or LH hinged
¤¥¦
60
§¥¦ ¨ ¤¥¦ ©
10 120 68 37
67
INSIDE
LDB = RAMB 136
Note:
· The ground must be level or sloped to guarantee smooth opening of the
double-leaf side door.
· Asymmetric division possible up to RAMB 2000 mm · With asymmetric division,
the clear passage width for the traffic leaf is
always 870 mm. · Min. size 1330 × 1960 (profile type 2) · Max. size 3000 ×
2558 (profile type 2)
INSIDE
Fitting arrangements
Fitting in the opening, opening outwards, right-hand hinged
f
Fitting in the opening, opening outwards or inwards, left-hand hinged
LMH LDH = LMH 78
RAMH = LMH 10
17
25.5
25 60
2
20 9.5
LDB GF LDB GF+ SF
LDB GF LDB GF + SF
40 68
Clear passage width with 90° leaf opening With surface-mounted hinges, maximum opening angle 180°
With concealed hinges, maximum opening angle 162°
W()
!$%&’ “#
W()
!
p
ABC
5634789@
ABC
0234
LDB 90° = RAMB 222 = LDB 52
Special sizes
Profile type 2 (fitting in the opening), S- / M- / L-ribbed
B
RM
A
RAMB
Min. RAMH
Max. RAMH
475
1900, 2375, 2850
500
2000
520 531
2080, 2600 2125
4
550
2205, 2750
562
2250
475
1900, 2375, 2850
1200 2500
500
2000
520
2080, 2600
531
2125
5
550
2205, 2750
562
2250
1960
2039 2139 2219 2263 2339 2387
2007 2107 2187 2231 2307 2355 2482 2558 2558 2558 2558 2558
LDB 90° = RAMB 296 = LDB 26
DRH
1050
A
No. of door sections
B
Door section height
DRH Lever height
FLAM Exterior leaf dimension
LDB Clear passage width
LDB 90° Clear passage width at an opening angle of 90°
68
LDH LMB LMH GF SF RAM
Clear passage height Structural opening width Structural opening height Traffic leaf Fixed leaf Overall frame dimension
RAMB Overall frame dimension width RAMH Overall frame height RM Grid height
Technical manual: Sectional garage doors / 03.2024
Side doors NT 60 ART 42
With corner frame made of aluminium profiles
External views The dimensions in the illustration correspond to the size of
the structural opening for 1000 × 2125 mm. Deviations may occur with other
door sizes.)
Corner frame
Internal or external fitting
Min.
B
RM
A
BRB*
BRH
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
4 550 1284 4 550 1284 4 550 1284 4 550 1284 4 550 1284 4 550 1284 5 550 1284 5 550 1284 5 550 1284 5 550 1284 5 550 1284 5 550 1284
1800 1800 1800 1800 1800 1804 2018 2118 2198 2242 2318 2366
Max. BRH
1986 2086 2166 2210 2286 2334 2461 2500 2500 2500 2500 2500
DRH
1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050
Note:
· NT 60 ART 42: Due to the different heights of the door bottom profiles, a
matching appearance with sectional door ART 42 is only possible to a limited
extent.
· Different design / performance characteristics for NT 60 ART 42 · Not
possible with equal height infills / openings
A
No. of door sections
B
Door section height
BRB Nominal size width
BRH Nominal size height DRH Lever height RM Grid height
Technical manual: Sectional garage doors / 03.2024
69
Side doors NT 60 ART 42
With corner frame made of aluminium profiles
H BRH = LMH 10 LDH = BRH 38 RAMH = BRH + 28 (LMH + 18)
67
(opening inwards)
5 38 52,5
(opening outwards)
118
DEF
118
GHQ
INSIDE
5 38 52,5
Internal fitting
External fitting
Internal fitting (opening inwards)
INSIDE
INSIDE
LH hinged
LMB BRB = LMB 10 LDB = BRB 76
RAMH = BRH + 28 (LMH + 18)
RS
50
RH hinged
RAMB = BRB + 56 (LMB + 46)
External fitting (opening outwards)
RAMB = BRB + 56 (LMB + 46)
LH hinged RH hinged
LDB = BRB 76 BRB = LMB 10
LMB
Clear passage width with 90° leaf opening
28 LDH = BRH 38 BRH = LMH 10 LMH
36
90°
FLAM = BRB 4
30 INSIDE
LDB 90° = BRB 114 = LDB 26
17 20 9,5
25 60
BRB BRH FLAM LDB
Nominal size width Nominal size height Exterior leaf dimension Clear passage width
70
LDB 90° Clear passage width at an opening angle of 90° LDH Clear passage height LMB Structural opening width LMH Structural opening height
RAMB Overall frame dimension width RAMH Overall frame height RAMH Overall frame height
Technical manual: Sectional garage doors / 03.2024
Side doors NT 60 ART 42
With block frame made of aluminium profiles
External views The dimensions in the illustration correspond to the size of
the structural opening for 1000 × 2125 mm. Deviations may occur with other
door sizes.)
Block frame
Internal or external fitting
B
RM
A RAMB*
Min. Max. RAMH DRH
RAMH
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
475 1900, 2375, 2850
500
2000
520
2080, 2600
531
2125
550
2205, 2750
562
2250
4 550 1330 4 550 1330 4 550 1330 4 550 1330 4 550 1330 4 550 1330 5 550 1330 5 550 1330 5 550 1330 5 550 1330 5 550 1330 5 550 1330
1800 1800 1800 1800 1800 1825 2039 2139 2219 2263 2339 2387
2007 2107 2187 2231 2307 2355 2482 2558 2558 2558 2558 2558
1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050
Note:
· NT 60 ART 42: Due to the different heights of the door bottom profiles, a
matching appearance with sectional door ART 42 is only possible to a limited
extent.
· Different design / performance characteristics for NT 60 ART 42 · Not
possible with equal height infills / openings
A
No. of door sections
B
Door section height
BRB Nominal size width
BRH Nominal size height DRH Lever height RM Grid height
Technical manual: Sectional garage doors / 03.2024
71
Side doors NT 60 ART 42
With block frame made of aluminium profiles
Fitting next to the door, opening outwards, RH or LH hinged TUVX
Fitting next to the door, opening inwards, RH or LH hinged
10 68
LDB
68 120
10 68 INSIDELDB = RAMB 136
R 68 120
R
INSIDE Y`ab
Fitting in the opening, opening inwards or outwards, RH or LH hinged cde
RAMB = LMB 20
Fitting behind the opening, opening inwards, RH or LH hinged
68
LMB = LDB
130
with support bracket
10 68
LDB = RAMB 136 INSIDE
Fitting behind the opening
68 10 Fitting in the opening
60
RAMB INSIDE
60
72,5
70 142,5
10 37 70
RAMH
LMH = LDH RAMH = LMH 10
INSIDE
OFF
INSIDE
Note:
Dowel holes in the frame must be selected additionally (not standard).
LDH = LMH 80 LMH
17
30
25 60
14
25 70
60
20 9,5
142,5
Clear passage width with 90° leaf opening With surface-mounted hinges, maximum
opening angle 180°
LDB 90° = RAMB 162 = LDB 26
ghi
uwstxy
qrst
With concealed hinges, maximum opening angle 162°
LDB 90° = RAMB 148 = LDB 13
90°
67
FLAM = RAMB 78
DRH Lever height FLAM Exterior leaf dimension LDB Clear passage width LDB 90°
Clear passage width at an opening angle of 90°
72
LDH LMB LMH R
Clear passage height Structural opening width Structural opening height Box section
RAMB Overall frame dimension width RAMH Overall frame height
Technical manual: Sectional garage doors / 03.2024
Hinged garage door DFT 42
Double-leaf garage door with block frame made of aluminium profiles
10 120
68 37
Fitting in the opening, opening outwards, RH or LH hinged
60
87 103
17
10 68
166 LDB = RAMB 136
INSIDE
68 10
· Max. size 3000 × 2500 mm · Min. size 1330 × 1960 mm
Note:
· The ground must be level or sloped to guarantee smooth opening of the
double-leaf garage door.
· Asymmetric division possible up to RAMB 2000 mm · With asymmetric division,
the clear passage width for the traffic leaf is
always 870 mm. · With operator LDH = LMH 150 mm.
Fitting arrangements
Fitting in the opening, opening outwards, right-hand hinged
INSIDE
LMH LDH = LMH 78 RAMH = LMH 10
30
25.5 18
25 43
2
20 9.5
60
LDB GF LDB GF + SF
Clear passage width with 90° leaf opening With surface-mounted hinges, maximum
opening angle 180°
40 68
With concealed hinges, maximum opening angle 162°
mno
de
jkhil
fghi
wxy
z{|
tursv
z{|
pqrs
LDB 90° = RAMB 222 = LDB 52
Special sizes
DFT 42 (fitting in the opening), S- / M- / L-ribbed
B
RM
A
RAMB
Min. RAMH
475
1900, 2375, 2850
500
2000
520 531
2080, 2600 2125
4
550
2205, 2750
562
2250
475
1900, 2375, 2850
1200 2500
500
2000
520 531
2080, 2600 2125
5
550
2205, 2750
562
2250
1960
2039 2139 2219 2263 2339 2387
Max. RAMH
2007 2107 2187 2231 2307 2355 2482 2500 2500 2500 2500 2500
LDB 90° = RAMB 296 = LDB 26
DRH
1050
A B DRH FLAM LDB
No. of door sections Door section height Lever height Exterior leaf dimension Clear passage width
LDB 90° Clear passage width at an opening angle of 90° LDH Clear passage height LMB Structural opening width LMH Structural opening height GF Traffic leaf
SF RAM RAMB RAMH RM
Fixed leaf Overall frame dimension Overall frame dimension width Overall frame height Grid height
Technical manual: Sectional garage doors / 03.2024
73
Brand quality for residential and commercial construction
The family-owned company Hörmann offers all important construction components
for building and renovating projects from a single source. We manufacture in
highly-specialised factories using the latest production technologies.
Furthermore, our employees work intensively on new products, continual further
developments and improvements to details. The results are patents and one-
of-a-kind products you can depend on.
Issue: 03.2024 / HF 84607 / Art. no.: 3 056 219 RE / EN https://www.hoermann.com/
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>