Dear Customer,
We thank you for choosing a quality product from our company.

 About these instructions

Read through all of the instructions carefully, as they contain important information about the product. Pay attention to and follow the instructions provided, particularly the safety instructions and warnings.
Further information about handling radio components can be found on the Internet.
Please keep these instructions in a safe place and make sure that they are available to all users at all times.

Safety instructions

2 .1 Intended use
The HET-E2 MCX BiSecur receiver is a bidirectional receiver for the actuation of operators and controls. It has two channels and is operated via the BiSecur radio. The receiver has two volt-free relay outputs and a 3-pin input for volt-free CLOSED barrier and OPEN barrier limit switch reporting.
Other types of application are prohibited. The manufacturer is not liable for damage caused by improper use or incorrect operation.
2 .2 Safety instructions for operating the receiver
CAUTION
Danger of injury from unintentional opening / closing
▶ See warning in section 8
ATTENTION
Functional impairment caused by environmental conditions Non-compliance with these instructions can impair function!
Protect the receiver from the following conditions:

  • Direct sunlight (permissible ambient temperature: -20 °C to +60 °C)
  • Moisture
  • Dust

NOTES:

  • After programming or extending the radio system, check the functions.
  • Only use original components when starting up or extending the radio system.
  • Local conditions may affect the range of the radio system.
  • When used at the same time, GSM 900 mobile phones can affect the range.

Scope of delivery

  • Receiver HET-E2 MCX BiSecur
  • Fitting and fixing material
  • External antenna
  • Operating instructions

Description of the receiver

HORMANN Receiver HET-E2-MCX BiSecur -
Description of the receiver

  1. Receiver
  2. Connecting terminal for 12 – 24 V DC power supply
  3. Connecting terminal of the relay outputs
  4. 3-pin connection terminal clamp, plug-in type
  5. Connection socket for external antenna
  6. Programming button P (P button)
  7. LED, blue (BU), programming
  8. Housing (optional)

4 .1 LED display
Blue (BU)

State Function
Illuminates once briefly A valid radio code was discovered for channel 1
Illuminates 2 times briefly A valid radio code was discovered for channel 2
Flashes once Receiver is in teach-in mode for channel 1
Flashes 2 x Receiver is in teach-in mode for channel 2
Flashes quickly after slow flashing A valid radio code was detected during

the teach-in procedure
Flashes slowly for 5 seconds, flashes quickly for 2 seconds| Device reset is being performed or completed
Off| Operation mode

4 .2 Button

P button Selection of the radio channel / relay

Fitting

HORMANN Receiver HET-E2-MCX BiSecur - Fitting NOTE :
By selecting an appropriate fitting location, the range can be optimised. The best orientation to achieve an optimum range must be established by trial and error.HORMANN Receiver HET-E2-MCX BiSecur - Fitting 1

Connection

HORMANN Receiver HET-E2-MCX BiSecur - Connection

Terminal E2 Normally open contact Connection of OPEN barrier travel limit
Terminal GND Shared contact 0 V reference potential
Terminal E1 Normally open contact Connection of CLOSED barrier travel limit

NOTE:
The maximum approved cable length is 30 m. The input terminal cable cross- section may be 0.08 – 1.0 mm²; all other terminals 0.12 – 1.5 mm².
The starting sequence begins when the receiver is supplied with 24 V DC voltage.
The blue LED remains lit, depending on the number of already taught-in radio codes, until the communication link is established.
No functions are permitted during this time. The receiver is ready for operation as soon as the blue LED goes out.
NOTE:
After a power failure, the receiver operates in the same way when the power returns.

Functions

The HET-E2 MCX BiSecur receiver has two volt-free relay outputs and a 3-pin input for two volt-free normally open contacts. The relay outputs permit the choosing directions Close and Open. The CLOSED barrier and OPEN barrier limit switch reporting is connected at the input.
Relay output 1 = press and hold (impulse 0.5 s)
Relay output 2 = press and hold (impulse 0.5 s)
7 .1 0 .5-second impulse function
When a transmission impulse is received, the relay is activated for 0.5 seconds and is then deactivated.
7 .2 Function of the P button
The P button is used to select the radio channel / relay on which a radio code is to be taught in.

Teaching in a radio code

**CAUTION
Danger of injury from unintentional opening / closing
Unintended movements may occur while teaching in the radio system.
▶ Make sure that no persons or objects are in the perimeter protection system’s area of travel when teaching in the radio system.
A maximum of 100 radio codes can be taught in on the receiver. They can be distributed over the existing channels as desired. If the same radio code is taught in on two different channels, it will be deleted on the channel that was taught in first. If more than 100 radio codes are taught in, the first ones to be taught in will be deleted.
In teach-in mode, the channels of the receiver can be switched by pushing the P button, so long as no radio code has been detected.
To activate / switch a channel:
▶ Press the P button once to activate channel 1.
▶ Press the P button 2 times to activate channel 2. To abort teach-in mode:
▶ Press the P button 3 times or wait for the timeout.
Timeout
If no valid radio code is detected within 25 seconds, the receiver automatically returns to the operation mode.
8 .1 Teaching in a radio code**HORMANN Receiver HET-E2-MCX BiSecur -
Teaching in a radio code

  1. Press the P button to activate the desired channel.
    – The blue LED flashes once for channel 1
    – The blue LED flashes twice for channel 2

  2. Switch the hand transmitter whose radio code is to be inherited to Inheriting /
    Transmitting mode.
    If a valid radio code is detected, the LED flashes quickly in blue and then goes out. The receiver is in operation mode .

Operation

In operation mode, the receiver signals the detection of a valid radio code by illuminating the blue LED.
NOTE:
If the radio code for the taught-in hand transmitter button was copied from another hand transmitter, the hand transmitter button must be pressed a second time during initial start-up.
A valid radio code channel 1 is discovered = The LED is illuminated briefly 1 time
A valid radio code channel 2 is discovered = The LED is illuminated briefly twice

 Feedback on the position of the perimeter protection

system
The HS 5 BiSecur hand transmitter only receives feedback if CLOSED barrier and OPEN barrier limit switch reporting is connected to the 3-pin input (E1/GND/E2).

| HS 5 BiSecur| LED
---|---|---
CLOSED barrier| Position: Closed| Green
OPEN barrier| Position: Open| Red
Barrier in motion| Position: Not open| Red
Position unknown / fault| Position: Not closed| Red
No feedback| Communication fault / out of range| Orange

10 .1 No feedback
After the command for manual position query
There is a communication fault or the receiver is out of range if the HET-E2 MCX BiSecur receiver does not receive feedback from the control within 5 seconds after the command. The HS 5 BiSecur hand transmitter does not subsequently receive any feedback from the receiver and the LED on the hand transmitter flashes orange rapidly 4 times.
After the command for automatic feedback on the position
The function for automatic feedback on the position is not supported by this receiver.

Reset

All radio codes are deleted by the following steps:

  1. Press and hold the P button.
    – The LED slowly flashes in blue for 5 seconds.
    – The LED flashes rapidly in blue for 2 seconds.

  2. Release the P button.
    All radio codes have been deleted .

NOTE:
If the P button is released prematurely, the device reset will be aborted and the radio codes are not deleted.

Disposal

**** Dispose of the packaging sorted by materials.
**** Electrical and electronic devices must be returned to the appropriate

recycling facilities.
****| Dispose of the batteries separately. Each consumer is legally required to leave batteries with a collection point in their community, their district, or with a trader.

Technical data

HET-E2-MCX BiSecur receiver

Model HET-E2-MCX-868-BS
Frequency 868 MHz
Transmitting power (EIRP) max. 20 mW
Power supply 12 − 24 V DC
Perm. ambient temperature −20 °C to +60 °C
max. humidity 93 % non-condensing
Protection category IP 65
Relay capacity max. 2,5 A / 30 V DC
Dimensions (W × H × D) 150 × 70 × 55 mm

EU and UK Declaration of Conformity
Hörmann KG Verkaufsgesellschaft and Hörmann UK Ltd. herewith declares that the radio equipment type HET-E2-MCX BiSecur receiver complies with the EU Directive 2014/53/EU and the UK Regulations 2017 No. 1206.
The complete text of the EU Declaration of Conformity and of the UK Declaration of Conformity can be found on the following website:

HORMANN Receiver HET-E2-MCX BiSecur - qr codewww .hoermann-docs.com/279230c

HET-E2-MCX BiSecur
Hörmann KG Verkaufsgesellschaft
Upheider Weg 94-98
33803 Steinhagen
Deutschland
4550722 B1