Instructions for use
Application
Enclosed and free-radiating wall luminaire made of hand-blown opal glass, with metal housing, for all lighting tasks in interior applications.
Product description Metal luminaire housing, finish Colour white Hand- blown opal glass Metal shield, white
2 mounting holes ø 4.5 mm Distance apart 250 mm
2 cable entries for through-wiring for connection cable up to ø 10,5 mm max. 5 x 1.5@
Connection terminal 2.5@ Earth conductor connection
2-pole connecting terminal for digital control
BEGA Ultimate Driver® LED power supply unit 220-240 V x 0/50-60 Hz DC 176-276 V
DALI-controllable
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
r – Safety mark c – Conformity mark Weight: 1.1 kg
This product contains light sources of energy
efficiency class(es) D
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against
e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at
Lamp
Module connected wattage 16.4 W
Luminaire connected wattage 19 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 45 °C
12 210.1 K3
Module designation LED-0594/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 2415 lm
Luminaire luminous flux 1335 lm Luminaire luminous efficiency 70,3 lm / W
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Lead the mains supply cable through the cable entry into the luminaire housing.
Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied. Establish earth conductor connection and make the electrical connection to the terminals. For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
Insert the glass into luminaire housing and fix it by screwing the shield hand-tight clockwise onto the glass.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Defective glass must be replaced.
Replacement of the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified
persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
Defective glass must be replaced. Close the luminaire.
Spares _
_Spare glass 11 003 167 .1
LED power supply unit DEV-0312/700
LED module 3000 K LED-0594/930
Shield 72 000 896 M