HORMANN HSI 6-15 Industrial Hand-Held Transmitter Instruction Manual

October 30, 2023
HORMANN

HORMANN HSI 6-15 Industrial Hand-Held Transmitter

Product Information

  • Can be used to send a wireless signal to control industrial gates and doors
  • Comes with a user manual in multiple languages including English, French, Spanish, Russian, Dutch, Italian, Polish, Hungarian, Czech, and Slovenian
  • Includes LED indicators for easy usage
  • Features a mix of BiSecur and fixed code 868 MHz operation modes
  • Requires batteries for operation (not included)
  • Dimensions: HSI 15 BiSecur – 75 x 14 x 11 mm; HSI 6 BiSecur – 62 x 35 x 14 mm

Product Usage Instructions

  1. Insert batteries into the transmitter according to the polarity markings
  2. Press the buttons on the transmitter to send wireless signals to control industrial gates and doors
  3. To learn and transmit a new code, refer to the user manual forspecific instructions based on the type of code being used (BiSecur or fixed code)
  4. To switch between BiSecur and fixed code modes, refer to the user manual for specific instructions
  5. To set the fixed code to 868 MHz, refer to the user manual for specific instructions
  6. The LED indicators will provide feedback on the status of the transmitter and help with troubleshooting if necessary
  7. Clean the transmitter as needed with a soft cloth and mild detergent

These instructions are divided into a text section and an illustrated section. They contain important information on the product, and especially safety instructions and warnings.

  • Read through the instructions carefully.
  • Keep these instructions in a safe place.

Safety instructions

Intended use

  • The industrial hand transmitter HSI 6 / 15 BiSecur is a unidirectional transmitter for operators and their accessories. It can be operated via BiSecur radio and the fixed code 868 MHz.
  • Other types of application are prohibited. The manufacturer is not liable for damage caused by improper use or incorrect operation.

Safety instructions for teach-in and operation
WARNING
Risk of injury during intended or unintended door travel

  • Make sure that hand transmitters are kept away from children and can only be used by people who have been instructed on how the remote-controlled door system functions!
  • If the door has only one safety device, only operate the hand transmitter if you are within sight of the door!
  •  Drive or walk through the door opening only when the door is in the Open endof- travel position!
  • Never stand in the door’s area of travel.
  • Note that accidentally pressing a button on the hand transmitter can result in door travel.
  • Make sure that no persons or objects are in the door’s area of travel when teaching in the radio system.

NOTES

  •  If there is no separate entrance, perform changes and extensions of radio systems while standing in the facility.
  • After programming or extending the radio system, you have to perform a function check.
  •  Local conditions may affect the range of the radio system.

Scope of delivery

  •  1.5 V batteries, type: AAA (LR03), alkalimanganese
  • Operating instructions
  •  Industrial hand transmitter HSI 6 / 15 BiSecur
  • Clip
  • Lanyard

Product description (see Figure 1 )

HORMANN-HSI-6-15-Industrial-Hand-Held-Transmitter-
fig-3

  1. LED, bi-colour
  2. Hand transmitter buttons
  3. Clip 6 Lanyard
  4. Cover cap
  5. Batteries

Initial start-up

Inserting the batteries
WARNING
Risk of explosion due to incorrect battery type

  • Use only this battery type: 1.5 V, type: AAA (LR03), alkali-manganese
  • Remove the battery from the hand transmitter if it is out of use for a long period of time.
    The industrial hand transmitter is ready for operation after having inserted the batteries.

Operation

Each hand transmitter button is assigned a radio code.

  • Press the button of the hand transmitter whose radio code you want to transmit.
    • The LED is illuminated blue for 2 seconds.
    • The radio code is transmitted.

Learning behaviour of inherited radio codes
If the radio code for the hand transmitter button has been inherited from a hand transmitter and is being used for the first time, proceed as follows depending on the product:

Garage door operator series 4, roller garage door operator series 2, receiver ESE BS HCP

  • Press and hold the hand transmitter button until the LED flashes alternately in red and blue and the desired function is performed. All other products
  • Press the hand transmitter button a second time.

Learning and inheriting / transmitting a radio code

WARNING
Risk of injury during intended or unintended door travel

  • See warning in section 1.2

Teaching in a radio code (see Figure ² )

HORMANN-HSI-6-15-Industrial-Hand-Held-Transmitter-
fig-4

  1.  Hold hand transmitter A that is to be taught in the radio code to the left of hand transmitter B.
  2. Press the hand transmitter button on hand transmitter B, whose radio code is to be inherited, and keep it pressed.
    • The LED is illuminated blue for 2 seconds and then goes out.
    • After 5 seconds, the LED alternates flashing in red and blue.
    •  The hand transmitter sends the radio code.
  3. Press the hand transmitter button on hand transmitter A that is to be taught in the radio code, and keep it pressed.
    •  The LED is illuminated blue for 2 seconds and then goes out.
    • The LED flashes slowly in blue.
    • If the radio code is recognised, the LED flashes rapidly in blue.
    • After 2 seconds, the LED goes out.
  4. Release the two hand transmitter buttons.
    The radio code of the hand transmitter button has been taught in.

NOTE
You have 15 seconds to inherit / transmit the radio code. If inheriting / transmitting the code was not successful within this period of time, repeat the process.

Mixed operation / BiSecur and fixed code 868 MHz
If BiSecur radio is configured, mixed operation (BiSecur and fixed code 868 MHz) is possible. The hand transmitter can learn radio codes from older hand transmitters (grey hand transmitter with blue buttons or device designation HSD2-868) with fixed code 868 MHz.

Reset

Each hand transmitter button is assigned a new radio code by means of the following steps.

  1. Open the hand transmitter housing.
  2. Remove the battery for 10 seconds.
  3. Press and hold a hand transmitter button.
  4. . Insert the battery.
    • The LED flashes slowly in blue for 4 seconds.
    • The LED flashes rapidly in blue for 2 seconds.
    • The LED is illuminated blue for a prolonged period of time.
  5. Release the hand transmitter button. All radio codes have been newly assigned.
  6. Close the hand transmitter housing.
    NOTE
    If the hand transmitter button is released prematurely, no new radio code is assigned.

Setting the fixed code 868 MHz

  1. Carry out steps 1 – 4 of the device reset.

  2. Keep the hand transmitter button pressed.

    • The LED slowly flashes in red for 4 seconds.
    • The LED flashes rapidly in red for 2 seconds.
    • The LED is illuminated red for a prolonged period of time.
  3. Release the hand transmitter button.
    The fixed code 868 MHz has been set.

  4. Close the housing.
    NOTE

    • If the hand transmitter button is released prematurely, the BiSecur radio connection will remain active.
    • For more information, visit www.hoermann.com.

LED display

Blue (BU)

Status Function
Illuminated for 2 seconds A radio code is being transmitted
Flashes slowly Hand transmitter is in teach-in mode
Flashes rapidly after slow flashing A valid radio code was detected during

the teach-in procedure
Flashes slowly for 4 seconds, flashes rapidly for 2 seconds, illuminated for a prolonged period| Device reset is being performed and completed

Red (RD)

Status Function
Flashes twice; following this, the radio code continues to be transmitted The

battery should be replaced soon
Flashes twice; following this, the radio code is no longer transmitted| The battery must be replaced immediately

Blue (BU) and Red (RD)

Status Function
Flashing alternately Hand transmitter is in inherit / transmit mode

Cleaning

ATTENTION

  • Damaging the hand transmitter by faulty cleaning
  • Only clean the hand transmitter with a clean, soft cloth.
    NOTE
    Regular use of disinfectants can cause damage to the hand transmitter.

Disposal

  • Dispose of the packaging sorted by materials
  • Electrical and electronic devices must be returned to the appropriate recycling facilities.
  • Dispose of the batteries separately. Each consumer is legally required to leave batteries with a collection point in their community, their district, or with a trader.

Technical data

  • Industrial hand transmitter HSI 6 / 15 BiSecur
  • Model HSI6-868-BS / HSI15-868-BS
  • Frequency 868 MHz
  • Transmitting power Max. 10 mW (EIRP)
  • Power supply 1.5 V batteries, type: AAA (LR03), alkali-manganese
  • Perm. ambient temperature –20°C to +60°C
  • Max. humidity 93%, non-condensing
  • Protection category IP 65
  • Dimensions (W × H × D)
    • HSI 6 BiSecur 50 × 90 × 25 mm
    • HSI 15 BiSecur 65 × 133 × 25 mm

EU and UK Declaration of Conformity

Hörmann KG Verkaufsgesellschaft and Hörmann UK Ltd. herewith declares that the radio equipment type Industrial hand transmitter HSI 6 / 15 BiSecur complies with the EU Directive 2014/53/EU and the UK Regulations 2017 No. 1206.
The complete text of the EU Declaration of Conformity and of the UK Declaration of Conformity can be found on the following website: www .hoermann-docs.com/277101